2/7/EN/6 Swirl Diffuser Type VDW recommended for room heights from approx. 2.60 ... 4.00 m
Abrir o catálogo na página 1
Description 2Discharge Characteristics > In addition to the existing range of TROX swirl diffusers, thetype VDW swirl diffuser with manual adjustment has been developed. This enables the direction of discharge to be altered on site to cater for changes in room layout or partitions. Due to the rotary swirling motion of the air discharge, induction of roomair occurs very quickly, resulting in a rapid decay of supply air velocity and temperature differential. Air change rates of 30 per hour can be achieved with supply air temperature differentials of +10K to ז10K. The diffuser can be supplied...
Abrir o catálogo na página 2
The flow visualisation opposite shows the air dischargecharacteristics, control blades set for internal swirl. > External swirlVerticalInternal swirl(normal position)air discharge > for sizes 300x8, 400x16, 500x24, 600x24 and 625x24 All air control bladesAir control blades setAir control blades in each quartile ofset to external swirlhalf to external andface are set in the same direction, adjacenthalf internal to swirlquartiles set one internal one external swirl >
Abrir o catálogo na página 3
300 298 600625 598 623 400 398 Test nipple Inclined manometer Plastic tube Code White sheathed cable damper open Diffuser face > 500 498 Green sheathed cable damper closed Plenum box >
Abrir o catálogo na página 4
The face plate is in galvanised sheet steel. The surfaces arepre-treated and powder coated white (RAL9010).The control blades are made from Polystyrol (PS 476L),with black (similar to RAL 9005) as standard or white (similar to RAL 9010) on request.The plenum box is made from galvanised sheet steel, therubber lip seal. All sizes are suitable for flush mounting into a ceiling.If the diffuser is installed below a closed ceiling (i.e. freelysuspended) a stable discharge can be achieved if a peripheral collar 50 mm is provided available onrequest. > The plenum box is suspended using wires or...
Abrir o catálogo na página 6
Vin l/s:Supply air volume per diffuserVin m > 3 /h:Supply air volume per diffuserA, Bin m:Spacing between two diffusers Xin m:Distance between diffuser centre and wallH > 1 in m:Distance between ceiling and occupied zonev- > H1 in m/s:Time average air velocity between two diffusersat distance from ceiling H > 1 Lin m:Horizontal + vertical distance (X+H > 1 )discharge to the wallv- > L in m/s:Time average air velocity at wall t > Z in K:Temperature difference between supply airand room air t > L in K:Difference between core and room temperatureat distanceL = A/2 + H > 1 orL = B/2 + H > 1...
Abrir o catálogo na página 7
in Pa t p in Pa t p Pressure drop Pressure drop in Pa t p in Pa t p Pressure drop Pressure drop
Abrir o catálogo na página 9
15010070 2010720305070150l/s100150200300400m 15010070 201074070100200300l/s200300400500m in Pa in Pa t t 5030 500 5030 900 p p in dB(A) L WA in dB(A) 202530354045L Pressure drop WA Pressure drop L 15 1540 10040 1540 15050 202530354045L 20253035404550 WNC 15 253035404550 WNC 200 400 3 /hV 3 /hV 7001200
Abrir o catálogo na página 10
100702010750070100200300l/s4002200300500m 1007020107500100200300l/s40022003000500m 5030 1200 5030 1200 in Pa in Pa t t p p in dB(A) 1540 150 in dB(A) L WA 1540 150700 WA Pressure drop 202530354045L Pressure drop 202530354045L L 253035404550 15 253035404550 15 20 20 WNC WNC 700 1000 3 /hV 90016004 3 /hV 90016004
Abrir o catálogo na página 11
Size Size in Pa in Pa t t p p Pressure drop Pressure drop Size Size in Pa in Pa t t p p Pressure drop Pressure drop
Abrir o catálogo na página 12
Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row ifB 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A 13 >
Abrir o catálogo na página 13
Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A or B 14 >
Abrir o catálogo na página 14
Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A 15 >
Abrir o catálogo na página 15
L should not exceed0.2 m/s. The regenerated noise level of each diffuser is limited to L Data given:A hall measuring BxLxH = 24mx24mx3.40m is to be designed using VDW swirl diffusers for supply air.Total volume flow rateV=16000 l/s (57600 m > WA = 30 dB(A).Initial observation:Since the diffusers have to be arranged at a distance of X = 3 m from the external facade, the remaining area available for installation is 18 m x 18 m. Consider a distance between rows B = 3.0 m This results in 7 rowsVper row = 16000 l/s 2280 l/s7For spacing of diffusers along the rows select A = 1.0 m.This results...
Abrir o catálogo na página 16
Diagram 11:Sound power level and pressure dropL > WA =27 dB(A) (L > WNC = 21 NC) p > t =12 PaDiagram 36:Square diffuser: more than one rowif B = 3.00 mH > 1 =H 1.70 = 1.70 mv > H1 =0.17 m/sDiagram 37:Temperature QuotientL=H > 1 + A/2 = 2.20 mbetween two diffusers t > L / t > Z =0.05 t > L =֖ 8 x 0.05 = 0,4 KL=H > 1 + X = 4.70 mat the wallv > L =0.18 m/s t > L / t > Z =0.023 t > L =֖ 8 x 0.023 = 0.2 K Result:133 off VDW- Q - Z - H / 600x24 At the required air change rate of 30 per hour, the noiselevel requirements are met and the limiting air velocities not exceeded. Correction!For an...
Abrir o catálogo na página 17
Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71!For adjustment of blade rings for external swirl, the diagram values must be multiplied by 1.25! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A or B 18 >
Abrir o catálogo na página 18Todos os catálogos e folhetos técnicos da TROX
-
Retrofit kits
6 Páginas
-
X-GRILLE Cover
18 Páginas
-
QUICK SELECTION GUIDE 2019 - 2
804 Páginas
-
QUICK SELECTION GUIDE 2019 - 1
530 Páginas
-
ATVC-100
8 Páginas
-
X-CUBE Compact
12 Páginas
-
X-CUBE RUN AROUND COIL SYSTEM
10 Páginas
-
Air-water systems
307 Páginas
-
ARR
2 Páginas
-
WT · WL · EL
8 Páginas
-
VMRK
4 Páginas
-
VFR
8 Páginas
-
Tunnel dampers
20 Páginas
-
FKS-EU
20 Páginas
-
CAK
6 Páginas
-
Type ST · XT
8 Páginas
-
Type ARK · ARK1
8 Páginas
-
Type NL
8 Páginas
-
Type JZ · JNE · JZ-L · JZD-G
20 Páginas
-
Type FSL-B-ZAB
4 Páginas
-
Type PKV
7 Páginas
-
Type BID
8 Páginas
-
Type QLI
8 Páginas
-
TVJ-Easy/TVT-Easy
12 Páginas
-
LVC
9 Páginas
-
RM-O-3-D
7 Páginas
-
RM-O-VS-D
7 Páginas
-
FK-EU
56 Páginas
-
EK-01
14 Páginas
-
XSA
12 Páginas
-
MSA
12 Páginas
-
SCHOOLAIR-V
12 Páginas
-
SCHOOLAIR-B
12 Páginas
-
FSL-B-SEK
4 Páginas
-
DID632
20 Páginas
-
DID300B
12 Páginas
-
DID312
16 Páginas
-
AGW
24 Páginas
-
AGS
24 Páginas
-
DLQ-1...4-AK
13 Páginas
-
DQ/ADQ
9 Páginas
-
DLQ/ADLQ
10 Páginas
-
DLK-Fb
4 Páginas
-
VD
10 Páginas
-
QSH · ISH
8 Páginas
-
DLQL
12 Páginas
-
X-CUBE
16 Páginas
-
FV-K90
12 Páginas
-
TVR-Ex _ TES/TEF
7 Páginas
-
AK-Ex
5 Páginas
-
JZ-RS
5 Páginas
-
FKRS-EU
28 Páginas
-
Multileaf Dampers
8 Páginas
-
Star Climate
16 Páginas
-
X-GRILLE-Basic
4 Páginas
-
X-GRILLE-Basic
3 Páginas
-
Jet nozzles TJN
3 Páginas
-
Diffusion grilles of stainless steel
4 Páginas
-
ARCHITECTURE NEEDS TO BREATHE
16 Páginas
-
SD
10 Páginas
-
AIRNAMIC
12 Páginas
-
XARTO
12 Páginas
-
X-CUBE COMPACT
10 Páginas
Catálogos arquivados
-
Displacement Flow Diffusers
32 Páginas
-
Product Summary
7 Páginas
-
Quick selection guide
48 Páginas
-
Air-water systems Design manual
60 Páginas
-
Slot Diffuser
11 Páginas
-
Passive Chilled Beams
7 Páginas
-
Swirl Diffusers
17 Páginas
-
Active Chilled Beams Type DID600B
12 Páginas
-
Grilles/Linear Grilles
24 Páginas
-
Ceiling Diffuser Type ADLR/ADLR-Q
14 Páginas
-
Swirl Diffusers Type FDE
6 Páginas
-
The art of handling air
80 Páginas