Excertos do catálogo

BS 476: Part 3: 2004 External Fire Exposure Roof Test Test Sponsor: Tapco Europe Limited
Abrir o catálogo na página 1
Warringtonfire Test Report No 153420 BS 476: Part 3: 2004 External Fire Exposure Roof Test Sponsored By Tapco Europe Limited Unit 32, Tokenspire Business Park, Hull Road Woodmansey East Yorkshire HU17 OTB
Abrir o catálogo na página 2
WF Report No. 153420 Page 4 of 9 Test Details
Abrir o catálogo na página 4
Description of Test Specimens The description of the specimens given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. Note 1 : The sponsor of the test has confirmed that no flame retardant additives were utilised in the production of the product / component. Note 2 : The sponsor was unable to provide this information.
Abrir o catálogo na página 5
Test Results Results of test The test results relate only to the behaviour of the test specimens of the construction under the particular conditions of test, they are not intended to be the sole criterion for assessing the potential fire hazard of the construction in use. The test results relate only to the specimens of the roof construction which were tested. Small differences in the composition or thickness of the construction may significantly affect the results of the test and may therefore invalidate the test results. Care should be taken to ensure that any construction which is...
Abrir o catálogo na página 6
Responsible Officer A Myler* Approved I Moore * Laboratory Supervisor Head of Department P E Lythgoe * * For and on behalf of warringtonfire. Report Issued: 28th April 2006 This version of the report has been produced from a .pdf format electronic file that has been provided by Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Warringtonfire. The original signed paper version of this report, which includes signatures in blue ink, is the sole authentic version. Only original paper...
Abrir o catálogo na página 7
Other observations: In the case of each specimen fire penetration did not occur.
Abrir o catálogo na página 8
Classification Of Specimens The following is reproduced from Clause 4 of BS 476: Part 3: 2004. 4 Classification Roof systems shall be designated by the letters EXT.F or EXT.S to indicate whether the test results apply to a flat (horizontal) or an inclined roof system, respectively 4.2 Fire Resistance of roof system Roof systems subject to conditions of external fire shall be classified according to both the time of penetration and the distance of spread of flame along their external surface. Each category designation shall consist of two letters, e.g. AA, AC, BB, these being...
Abrir o catálogo na página 9
Warrington Fire Research Centre Ltd - Holmesfield Road - Warrington - Cheshire - UK - WA1 2DS t: +44 (0) 1925 655116 - f: +44 (0) 1925 655419 - w: warringtonfire.net
Abrir o catálogo na página 10Todos os catálogos e folhetos técnicos da Tapco Roofing Products
-
TapscoSlate Fixing Guide
26 Páginas
-
Dry verge fixing guide
1 Páginas
-
Tapcoroofing Brochure
8 Páginas
-
Self-Build Homes Fact Sheet
2 Páginas
-
Re-Roof Your Home Fact Sheet
2 Páginas
-
Outdoor Living Fact Sheet
2 Páginas
-
Modular Homes Fact Sheet
2 Páginas
-
Conservatory Roof Fact Sheet
2 Páginas
-
Features and Benefits Fact Sheet
2 Páginas
-
40-year Warranty
2 Páginas
-
TapcoSlate Wind Load Performance
1 Páginas
-
LABC Registered Details Fact Sheet
1 Páginas
-
LABC Registered Details Certificate
7 Páginas
-
ISO 9001 Certificate
2 Páginas
-
TapcoSlate Fire Safety Report Part 2
10 Páginas
-
TapcoSlate Classic ETA Certification
4 Páginas
-
TapcoSlate Classic BBA Certification
8 Páginas
-
Tapco Chemical Compatibility
1 Páginas
-
RidgeMaster & HipMaster Fixing Guide
4 Páginas
-
Tapco Cowl Vent Fixing Guide
1 Páginas
-
Tapco Abutment Ventilator
1 Páginas
-
Wunderlay
2 Páginas
-
VP300
2 Páginas
-
Tapco Inline Vent Fixing Guide
7 Páginas