

Excertos do catálogo

05/17 - 2 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 2
Description The air diffuser type ZMD is an air diffuser for universal use in all mounting situations. Owing to its infinitely variable adjustment from long-throw to wide-angle diffusion, it is universally suited to ventilate all types of rooms, particularly high-ceiling halls, rooms with considerable heat generation, behind raster ceilings, etc. Suitable for all air-conditioning systems. Installation is possible in any ceiling construction. The ZMD diffuser head has several rows of apertures, arranged in a specific relationship. The front apertures can be completely or partially closed by...
Abrir o catálogo na página 3
ZMD air diffuser Models and dimensions Minimum setting Air throw pattern Wide angle setting Adjusting disc Long throw setting Standard setting: maximum To reduce the flow rate, i.e., increase the pressure loss, by means of the nozzle, the diffuser head can be slid towards the rear, by loosening the slotted screws on the side, until the upper row is covered (minimum position). The volumetric flow can be determined, as shown in the pressure loss diagrams, by means of a static tube. Increase of noise due to the damping should be taken into consideration. In the long throw position, the...
Abrir o catálogo na página 4
for duct installation - K00 (with curved blade, -K01) for ceiling installation -D00 (with cover plate, -D01) Curved blade sectional view 1.) Screw mounting * Sheet metal collar Cover plate *Part 1 fitted only if delivered with sheet metal collar 1.) On-site mounting holes for installation in round ducts, -RA0 / -RB0 / -RC0 (with curved blade, -RA1 / -RB1 / -RC1) Curved blade The sheet metal collar (-BK1) is delivered loose and can be fixed to the connection spigot with a self-tapping screw during onsite assembly. The sheet metal collar (-BK1) cannot be retrofitted, as part 1 is not included...
Abrir o catálogo na página 5
ZMD air diffuser Dimensions of accessories Jet guide (jet shielding) Guide ring. to be used for wide-angle jet only Plug for shielding columns and walls, etc. Adjusting disc Plug for shielding columns and walls, etc. (-X) Number of plugs can be freely selected (1 < x < 9) 05/17 - 6 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 6
ZMD air diffuser Technical data Pressure loss and noise level ZMD-100 wide-angle setting (max.) sound power level ZMD-150 Total pressure loss ZMD-150 long throw (max.) ——— The values apply to hose connections. They decrease by approximately 4 dB for pressure duct connections. Relative difference in sound power level (RS) Hz ZMD-150 long throw max. 05/17 - 7 Construction subject to change. Version: 17.02.2020 No return poss
Abrir o catálogo na página 7
ZMD air diffuser Maximum end velocity of jet ZMD-100 wide-angle setting (max.) 05/17 - 8 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 8
ZMD air diffuser Critical throw Maximum penetration ZMD-150 (heating) long throw (max.) Room height 05/17 - 9 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 9
ZMD air diffuser Temperature and induction ratios ZMD-100 05/17 - 10 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 10
ZMD air diffuser Further data Selection diagram: ZMD-150 wide-angle setting (max.) Relative sound power level difference Read temperature ratio TV for determining the temperature ∆Tx in the diagram. For the jet throw x + jet throw y, the value x from the diagram must be used. 05/17 - 11 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 11
ZMD air diffuser Selection diagram: ZMD-150 wide-angle setting (min.) Relative sound power level difference Read temperature ratio TV for determining the temperature ∆Tx in the diagram. For the jet throw x + jet throw y, the value x from the diagram must be used. 05/17 - 12 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 12
ZMD air diffuser ZMD-150 wide-angle setting (max.) Two opposite jets ZMD-150 wide-angle setting (min.) Two opposite jets 05/17 - 13 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 13
ZMD air diffuser ZMD-150 wide-angle setting (max.) with wall effect Acoustic data ZMD-150 wide-angle setting (min.) with wall effect For VR, the following values must be used: sound-attenuated room = VR x 2, normal room = VR and hard room = VR x 0.5 05/17 - 14 Construction subject to change. Version: 17.02.2020 No return possible!
Abrir o catálogo na página 14
Supply air volume Room volume Maximum end velocity of jet Face area horizontal throw vertical throw Critical jet path Density Pressure loss A-weighted sound power level Temperature difference between supply air temperature and room temperature (DTO = tZU - tR) Temperature difference between air supply and room temperature in heating mode (DTOH = tZUH - tRH) Temperature difference at point x Supply air temperature Room temperature Induction ratio (i = VX / VZU) Temperature ratio (TV = DTX / DTO) Room height Nominal width Room attenuation Penetration depth in heating mode Horizontal +...
Abrir o catálogo na página 15
ZMD air diffuser ZMD order code 01 All fields must be filled when ordering. Sample ZMD-100-9010-SM-D01-BK0-9010-0 Air diffuser type ZMD I Nominal width 100 I Nozzle head colour RAL 9010 (white) I With screw mounting I For ceiling installation with cover plate | Without sheet metal collar | Sheet metal parts painted to RAL colour 9010 (white) | Without shielding plug Order details 01 - Type ZMD = Air diffuser type ZMD 02 - Nominal width 100 = Nominal width 100 mm 150 = Nominal width 150 mm 03 - Nozzle head colour 9005 = RAL colour 9005 (polystyrene, black) 9010 = RAL colour 9010...
Abrir o catálogo na página 16
ZMD air diffuser Specification texts Air diffuser with high inductive effect, flame-resistant. Consisting of a plastic (polystyrene 4754) diffuser head with radially arranged apertures with integrated adjustable damper disc and connection spigot. Product: SCHAKO type ZMD-100/-150 Model: ZMD-...-D00 ZMD-...-D01 ZMD-...-K00 ZMD-...-K01 ZMD-...-RA0 ZMD-...-RA1 = for ceiling installation (without cover plate) = for ceiling installation (with cover plate) = for duct installation (only possible without cover plate) = for duct installation with curved blade (only possible without cover plate) =...
Abrir o catálogo na página 17Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas