Volumetric flow controller VRAQ Description A volumetric flow controller is used for pressure-independent volumetric flow regulation in ventilation and air-conditioning systems. It is used to keep the volumetric flow constant (CAV) within specified limits or to control it variably (VAV) as a function of a command variable, for example a room temperature controller, DDC or bus system. For constant volumetric flows, the operating stages CLOSED/Vmin/Vmid/Vmax/OPEN are available in stage operation, controlled via relays or switches. The housing, measuring sensor, control flap, PI controller...
Abrir o catálogo na página 3
Volumetric flow controller VRAQ All volumetric flow controllers can be assembled with horizontal or vertical damper axis.
Abrir o catálogo na página 4
Volumetric flow controller VRAQ Construction Housing - Galvanised sheet steel (-SV) - Galvanised sheet steel with DD coating inside (-DD) (only available for VRAQ-HKP and VRAQ-HKU) Damper leaf seal - made of PUR, silicone-free - for airtight sealing design to DIN EN 1751 Damper bearing - Brass (VRAQ H=100) - Plastic (VRAQ-HKP and VRAQ-JK-LP) - Sintered (VRAQ-HKU and VRAQ-JK-LU) Blades - Opposed, made of galvanised steel sheet, not air-tight (VRAQ-HKP and VRAQ-HKU) - opposed, made of extruded aluminium profiles, air-tight sealing to DIN 1751. (VRAQ-JK-LP and VRAQ-JK-LU) Measuring cross -...
Abrir o catálogo na página 5
Volumetric flow controller VRAQ Models and dimensions DimensionsLouvre profileVRAQ-HKP / VRAQ-HKU H = 100-180 / W = 140-565 with electric controller VRAQ-...-DS0, without acoustic cladding VRAQ-JK-LP / VRAQ-JK-LU 40 mm thick sound-absorbing material is pressed to 35 mm, with sheet metal casing H = 100-180 / W = 140-565 with pneumatic controller not available Available sizes x = available -- = not available ca. = approx. All combined lengths and heights available. The VRAQ is only delivered in right-hand design. If the left-hand design, with the controller and motor on the left, is required,...
Abrir o catálogo na página 6
with pneumatic controller VRAQ-...-DS0, without acoustic cladding Volumetric flow controller VRAQ H = 201-1003 / W = 201-1003 with electric controller VRAQ-...-DS0, without acoustic cladding VRAQ-...-DS4, with acoustic cladding 40mm VRAQ-...-DS4, with acoustic cladding 40mm 40 mm thick sound-absorbing material is pressed to 35 mm, with sheet metal casing 40 mm thick sound-absorbing material is pressed to 35 mm, with sheet metal casing Available sizes VRAQ-HKU-... / VRAQ-HKP-... x = available -- = not available All combined lengths and heights available. S* = Projection length with a damper...
Abrir o catálogo na página 7
Volumetric flow controller VRAQStandard controller selection with electric controller (standard): Construction subject to change.
Abrir o catálogo na página 8
Volumetric flow controller VRAQ Damper blade leakage VRAQ, classification according to DIN EN 1751 Construction subject to change.
Abrir o catálogo na página 9
Volumetric flow controller VRAQAccessories - dimensions Mineral wool silencer (-ZSQ) with baffles MWK-OB Available sizes and insertion loss for mineral wool silencer (-ZSQ) H“ (mm) 100 140 160 180 201 225 252 318 357 400 449 503 565 634 711 797 894 1003 The possible width and height combinations are listed on page 7. Please note! The parameters KA (number of baffles), K (baffle strength ) and Mineral wool silencer ZSQ must be ordered separately! S (gap width ) depend on the width B. Construction subject to change.
Abrir o catálogo na página 10
Volumetric flow controller VRAQ Technical data Information for parameterisation Attention, the following specifications are important for the programming of the volumetric flow controllers: - this table specifies the complete measuring range of the standard controller (volumetric flow range). - If the customer absolutely wants a calibration curve different from 12 m/s, it must be specified! - When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! - If only one air volume is specified in the order (as...
Abrir o catálogo na página 11
with electric controller (standard) H (mm) - MIN values refer to air velocity of 1 m/s - MAX values refer to air velocity of 12 m/s H=318 for VRAQ-JK-LP / VRAQ-JK-LU not available. -- = not available Construction subject to change.
Abrir o catálogo na página 12
Volumetric flow controller VRAQ Acoustic data VRAQ H= 100-180 / W= 140-565 A-weighted sound power level LWA [dB(A)]Flow generated noiseH (mm) 100 140 160 vk (m/s) 12 12 12 140 49 Lwa [dB(A Radiated noise VRAQ-...-DS0 (without acoustic cladding) 08/61 - 13 Construction subject to change.
Abrir o catálogo na página 13
Volumetric flow controller VRAQRadiated noise VRAQ-...-DS4 (with acoustic cladding)08/61 - 14 Version: 13.03.2020 Construction subject to change.
Abrir o catálogo na página 14
Volumetric flow controller VRAQAcoustic data VRAQ H= 201-1003 / W= 201-1003 Inflow area A (m2) Construction subject to change.
Abrir o catálogo na página 15
Volumetric flow controller VRAQ Technical data of the control components Measured value collection and control function The measured value collection is carried out via a flow-favouring double measuring cross. The measuring openings are distributed over the measuring cross according to the median line method. The pressure differential formed on the measuring cross is determined by means of a dynamic or static measuring sensor. The measured values are averaged to give an average value which represents a measuring quantity for the volumetric flow. The controller compares the actual value...
Abrir o catálogo na página 16
Volumetric flow controller VRAQ MP bus activation with integrated switch Circuit diagrams Circuit diagram electric controller (standard) Compact controller Belimo make: LMV-D3-MP / NMV-D3-MP / SMV-D3-MP VAV with analogue command signal VAV with lock (CLOSED) Mode 2-10 V DC Cable designations Lock mode (CLOSED) In the 2...10 V mode, the following function can be carried out with a 0...10 V signal: Contact closed, function active Contact closed, function active, in mode 2 ...10 V only Contact open * not available for DC 24 V supply Construction subject to change.
Abrir o catálogo na página 17Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas