Volumetric flow controller VAQS® Description ® The VAQS volumetric flow controller impresses with its simple design, high measuring precision and short length, meeting the majority of customary requirements of volumetric flow controllers. - simple design in accordance with the nominal size of the air duct. This simple design saves a lot of time and provides planning safety. - high controlling precision Due to its high controlling precision, the controller requires a straight flow section of only 1 x D even after bends. - Blades sealing airtight to DIN EN 1751, Class 3 - Housing leakage air...
Abrir o catálogo na página 3
Volumetric flow controller VAQS® Field of application - for supply and return air systems - for constant or variable volumetric flows - Positive control Vmin, Vmax, "OPEN" or “CLOSED” - Suitable for constant and variable volumetric flow or duct pressure control - differential pressure range from 20 to 1000 Pa - for duct velocities of 1 - 12 m/s - for ambient temperatures of 0 - 50°C When installing volumetric flow controllers, for example in roof central units, in extreme cases, condensation can build up in the measuring pipes of the volumetric flow controller as a result of the large...
Abrir o catálogo na página 4
Models and dimensions Dimensions VAQS® ...-DS0 Volumetric flow controller VAQS® Construction Housing - Galvanised sheet steel - Galvanized sheet steel with DD coating Blades - opposed, made of extruded aluminium profile Blade seal - made of PUR, silicone-free - for airtight design to DIN 1751, Class 3 Blade support - plastic Measuring rods - Aluminium Model VAQS® - Rectangular design, for duct connection to DIN EN 1505, for rectangular model, with blade seal. (air-tight to DIN EN 1751, Class 3) - Housing leakage air flow to DIN EN 1751, class B - with electric controller LMV/NMV-D3-MF, not...
Abrir o catálogo na página 5
Volumetric flow controller VAQS® Available sizes and insertion loss for mineral wool silencer (-ZSQ) B (mm) The parameters KA (number of baffles), K (baffle strength ) and S (gap width ) depend on the width B. Construction subject to change.
Abrir o catálogo na página 6
Volumetric flow controller VAQS® Technical data Inflow area A (m2) H (mm) Flow generated noise (A = 1 m2) Construction subject to change.
Abrir o catálogo na página 7
Volumetric flow controller VAQS® Volumetric flow range for VAQS® When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! Volumetric flow range - this table specifies the complete measuring range of the standard controller (volumetric flow range). - If the customer absolutely wants a calibration curve different from 12 m/s, it must be specified! - When the air volume drops below the Vmin shown in the chart, the correct functioning of the volumetric flow controller is no longer guaranteed! - If only one...
Abrir o catálogo na página 8
Volumetric flow controller VAQS® Technical data for Belimo components Operating control Belimo components Measured value collection and control function The measured values are collected by two measuring rods favourable to the flow. The measuring openings are distributed over the measuring rods according to the median line method. The pressure differential formed on the measuring rods is determined by means of a dynamic or static measuring sensor. From these measuring results the middle value is formed, which gives a measured variable for the volume flow. The controller compares the actual...
Abrir o catálogo na página 9
Volumetric flow controller VAQS®Circuit diagrams Compact controller Belimo make LMV/NMV-D3-MF - Attention: not MP-bus-capable VAV with analogue command signal VAV with lock (CLOSED)Mode 2-10V DC - + DC 24 V -1 VAV command signal 0...10V/2...10V MP / actual value signal 0...10V / 2...10V on site Switchover CLOSED / VAV operation _MP / actual value signal 0...10V / 2...10V on site Lock mode (CLOSED) In the 2 - 10 V mode, the following function can be carried out with a 0 - 10 V signal: Note: Please ensure mutual locking Function Damper CLOSED Vmin...Vmax CAV - Vmin Damper OPEN CAV - Vmax...
Abrir o catálogo na página 10
Volumetric flow controller VAQS® LED table of functions for LMV/NMV-D3-MF Application N1 operation Function Status display Description / action - 24V power supply o.k. - VAV-Compact ready for operation Adaptation Address S1 service function Synchronisation Synchronisation started by: a) Operating / service unit b) Manual trigger device at the VAV-Compact c) Power ON behaviour S2 service function Adaptation Adaptation started by: a) Operating / service unit b) Key on the VAV-Compact a) Press both keys «Adaptation» & «Address» simultaneously b) VAV service will be activated: - until 24V...
Abrir o catálogo na página 11
Volumetric flow controller VAQS® Setting the operating potentiometers / calculation formulae Actual value measurement via feedback signal U5 using a voltmeter or PC-Tool LMV/NMV-D3-MF Set value for Vmax V max = --------------- × 100% EW V max V nenn The required volumetric flow that is to flow at the 10 V DC command signal at terminal 3 (Y) or with positive control Vmax is set in % at the Vmax potentiometer of the controller, the ZTH-EU or PC-Tool. This value refers to the set Vnenn nominal volumetric flow. Set value for Vmin EW V Supply voltage: 24 V AC/DC (Terminals 1+2) Measurement...
Abrir o catálogo na página 12
Volumetric flow controller VAQS®Technical data of the controller Functional control LMV/NMV-D3-MF (make Belimo) Dynamic pressure sensor, digital VAV controller and damper drive VAV-Compact solution Measuring principle : Pressure reading with volumetric flow Measuring range of the 2... ~ 450 Pa sensor : Supply voltage : Functional range : Power consumption: Dimensioning : Torque : Control function : Setting range Vmin/Vmax : AC 24 V 50/60 Hz; DC 24 V AC 19.2...28.8 V; DC 21.6...28.8V 2 W / 3W 3.5 VA / 5 VA min. 5 Nm/10 Nm at the rated voltage VAV/CAV/Open-Loop; Supply/return air or...
Abrir o catálogo na página 13
Volumetric flow controller VAQS® Startup using PC-Tool Direct connection in the switch cabinet or socket (traditional application) ZTH EU as MP level converter Local connection via a service socket of the MF/MP or LON drive using a ZK1-GEN cable. Connection diagram 2 Description The ZTH EU is also a potential-free interface between the USB port of a PC and the Belimo MP bus. It is used to connect the Belimo PC-Tool directly to the MP bus or directly to a programmable MFT drive. Power supply The ZTH EU is supplied with power by the USB port. The MP bus voltage is obtained internally by means...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas