Description The particle filter unit, type FKW, has been particularly developed for use in cleanrooms required by the pharmaceutical, electronical, precision mechanical and optical industry in hospitals and laboratories. The integrated particle filter (to DIN EN 1822) removes particles, radioactive dust, mist, bacteria, viruses, etc., from the supply or return air. This ensures that the incoming and outgoing air flows are extremely clean and germ-free. The filter box type FKW consists of electrolytically galvanised sheet steel painted to RAL 9010 (white). A filter pressure device in the...
Abrir o catálogo na página 3
Particle Filter Box FKW Accessories Seal leakage monitoring system (-P1) - inside the box for filters with U seal only Differential pressure device / aerosol monitoring device additionally with 2 measuring spigots on the box outside for a hose with an inner diameter of 4 mm (-D2) Differential pressure device / aerosol monitoring device additionally with 2 measuring spigots on the box outside for a hose with an inner diameter of 4 mm and an aerosol feeding device in the spigot from the box inside (-D3) Differential pressure device / aerosol monitoring device additionally with an aerosol...
Abrir o catálogo na página 4
Particle Filter Box FKW Models and dimensions Dimensions Air diffusers: Ventilation grille type AL2 Air diffuser type DBB-A Mounting bracket with long hole ø 10 x 20 Mounting bracket with long hole ø 10 x 20 07/07 - 5 Construction subject to change. Version: 22.03.2018 No return possible!
Abrir o catálogo na página 5
Mounting bracket with long hole ø 10 x 20 Mounting bracket with long hole ø 10 x 20 Attention! With modified connecting piece, a motor cannot be fitted to the shut-off damper! 07/07 - 6 Construction subject to change. Version: 22.03.2018 No return possible!
Abrir o catálogo na página 6
Connection flange suitable for Metu systems HM 20 and HM 30 Mounting bracket with long hole ø 10 x 20 Mounting bracket with long hole ø 10 x 20 Internal differential pressure measuring / aerosol monitoring device (-D1, standard) Section A-A 07/07 - 7 Construction subject to change. Version: 22.03.2018 No return possible!
Abrir o catálogo na página 7
“HAk#Particle Filter Box FKW Dimensions of accessories Differential pressure device / aerosol monitoring device additionally with 2 measuring spigots on the box outside for a hose with an inner diameter of 4 mm (-D2) Seal leakage monitoring system inside the box (-P1) (only possible with U seal) Differential pressure device / aerosol monitoring device additionally with 2 measuring spigots on the box outside for a hose with an inner diameter of 4 mm and an aerosol feeding device in the spigot from the box inside (-D3) Differential pressure device / aerosol monitoring device additionally with...
Abrir o catálogo na página 8
Particle Filter Box FKW Filter assembly instruction Maintenance In addition to keeping machines and equipment clean, the maintenance of the filters is especially important. A constant control of the filters is as essential as changing them when the maximum allowed particle absorption has been reached. The inspection must take place at short enough intervals to allow faults that have occurred or become apparent to be eliminated in time. The necessary intervals are set depending on the local conditions. The measured variable for the particle intake of the filter is the pressure difference....
Abrir o catálogo na página 9
Particle Filter Box FKW Technical data Pressure loss An H13 filter unit cannot be used as H14 filter! If the particle filters are designed according to filter class H14, make sure that the air volume at the front plates is checked. Thus, it may happen that the air volume is too low for the selected faceplate, resulting in an uncontrolled jet drop. In this case, we recommend using a faceplate with a smaller perforation. Filter class according to DIN EN 1822 Filtration efficiency in MPPS: H13 = > 99.95 % H14 = > 99.995 % Allowed final pressure: max. 500 Pa Construction subject to change.
Abrir o catálogo na página 10
Attention! - Connection via safety transformer. - Parallel connection of further drives is possible. Observe specifications. Connection diagram E002 / E031 OPEN/CLOSED control N L 230 VAC M) N L L Attention! - Connection via safety transformer. - Parallel connection of further drives is possible. Observe specifications. Construction subject to change.
Abrir o catálogo na página 11
ICHAKO KLIMA-LUFT Technical data of motorsLM24A (-E001) / LM24A-S (-E030) (make Belimo) LF230 (-E020) / LF230-S (-E036) (make Belimo) rated voltage: Functional range : Power consumption : Dimensioning : Torque : Running time : Sound power level: Protection class : Degree of protection : EMC: 24 V AC/DC, 50/60 Hz 19.2...28.8 V AC/DV - Operation: 1 W - Idle position: 0.2 W 2 VA Min. 5 Nm 150 s 35 dB (A) III Safety extra low voltage IP54 in all mounting positions CE according to 89 / 336 / EEC rated voltage: Functional range : Power consumption : Torque : Running time : Sound power level:...
Abrir o catálogo na página 12
ICHAK#Particle Filter Box FKW Order code FKW 01 Sample FKW-1-H-DBB-MB-SB-9010-AB0-M000-D1-U0-P1-GD1-KHS-SDS Particle filter box type FKW I filter height 90 mm I connection from above with round spigot I air diffuser DBB I magnetic fastening I sheet steel I painted to RAL9010 I without antibacterial coating I without shut-off damper I with differential pressure / aerosol monitoring device inside I without differential pressure transducer I with tight seal test I with rubber lip seal I height of plenum box standard I spigot diameter standard Order details 01 - Type FKW = Particle filter box...
Abrir o catálogo na página 13
Particle Filter Box FKW 10 - Differential pressure / aerosol monitoring device D1 = with differential pressure / aerosol monitoring device inside (standard) D2 = with differential pressure / aerosol monitoring device inside and with pressure take-off point filter / room outside D3 = with differential pressure / aerosol monitoring device inside, with pressure take-off point filter / room outside and aerosol monitoring inside the box (spigot) D4 = with differential pressure / aerosol monitoring device inside and aerosol monitoring inside the box D5 = with differential pressure / aerosol...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas