DSX
1 / 25Páginas

Excertos do catálogo

DSX - 2

04/03 - 2 Construction subject to change. Version: 06.09.2018 No return possible!

Abrir o catálogo na página 2
DSX - 3

Ceiling Slot Diffuser Model Description The small ceiling slot diffuser type DSX-S is suitable for installation in closed ceiling systems, in rooms of heights 2.6 to 4 m. In panelled ceilings, the use of the black (RAL 9005) air guide element allows an approximately invisible installation of the slot diffuser. The models DSX-P, DSX-PA and DSX-PB with support profile are suitable for installation in ceiling panels. Adjustments of the blades enable the diffuser to be used for cooling and heating applications. The high induction ensures fast reduction of the air outflow velocity and of the...

Abrir o catálogo na página 3
DSX - 4

Ceiling Slot Diffuser ModelAccessories Fastening Plenum box (-ASK) permanent connection - Galvanised sheet steel, with lateral connection spigot and fix- - Standard for models DSX-S, DSX-P, DSX-PA and DSX-PB ing lugs. Clamp fastening Damper (-DK) - Installation of the DSX-P and DSX-PB without plenum box - Damper fastening made of plastic in pressure ceilings. - Damper made of galvanised perforated sheet - supplied loose as standard Corner angle 90° (-EW) Concealed mounting (-VM) - Extruded aluminium profile (in same colour as DSX) - Standard for band design with plenum box (-ASK) M4...

Abrir o catálogo na página 4
DSX - 5

Ceiling Slot Diffuser Model Models and dimensions Air throw pattern Air guide element position (throw direction): vertical (-L I) one-way horizontal throw to the left (-L II L) one-way horizontal throw to the right (-L II R) alternate horizontal throw (-L III, standard) all adjacent blades will be set in one direction when ordering multi slot models Return air 04/03 - 5 Construction subject to change. Version: 06.09.2018 No return possible!

Abrir o catálogo na página 5
DSX - 6

Ceiling Slot Diffuser Model Dimensions DSX-S, without support profile For installation in closed ceiling systems or for invisible installation in the joint of panelled ceilings. DSX-P: with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems. DSX-PA, with support profile For installation in closed ceiling systems anodised model painted model anodised model painted model anodised model painted model anod. model paint. model DSX-PB, with support profile For installation in ceiling panels, suitable for installation in closed ceiling systems....

Abrir o catálogo na página 6
DSX - 7

Ceiling Slot Diffuser Model Dimensions of accessories Plenum box (-ASK) for DSX-S / DSX-P / DSX-PA / DSX-PB View A with 1 spigot with 2 connection pieces Detail X / diffuser mounting Standard: at an extra charge: on site = Height of plenum box = Total height Available sizes To facilitate ceiling mounting, the plenum boxes can be provided with an M4 riveting nut. This is to be carried out on site if diffusers are ordered without plenum boxes. Insulation for plenum box internal (-Ii) Rubber lip seal (-GD) Detail Y 04/03 - 7 Construction subject to change.

Abrir o catálogo na página 7
DSX - 8

When the ceiling slot diffuser type DSX is designed as a band > 2000 mm, the total length BL is assembled from standard lengths L = 1500 mm. The difference pieces <1500 mm to >400 mm can be fitted with a plenum box. The difference pieces <400 mm are supplied as dummy pieces without plenum box. A different band division is possible after consultation and when required by the customer. Individual sections are connected (for mounting on site) by using double blades. Construction subject to change.

Abrir o catálogo na página 8
DSX - 9

Ceiling Slot Diffuser Model Double blade Detail of connection element 1 Connection element 1 not possible when diffuser is suspended with riveting nut and band design is used. Mounting handle for double blade Double blade active - passive Detail of connection element 3 Fastening screw: Torx screw M4 DIN 7991-TX passive - passive Fastening screw: Torx screw M4 DIN 7991-TX 04/03 - 9 Construction subject to change. Version: 06.09.2018 No return possible!

Abrir o catálogo na página 9
DSX - 10

Ceiling Slot Diffuser Model Dummy piece (-BS) DSX-S-1 W m Detail W Mounting bracket (pair) (-BW) for operation with overflow air DSX-S-1 V Detail V mu Arrangement of the mounting holes in the dummy plate DSX-...-1 (1-slot) with 2 mounting holes Arrangement of the mounting holes DSX-...-1 (1-slot) with 2 mounting holes DSX-...-2 to DSX-...-4 (2- to 4-slot) with 4 mounting holes DSX-...-2 to DSX-...-4 (2- to 4-slot) with 4 mounting holes In the dummy design, no operation with overflow air is possible since the slot diffuser is completely closed at the back. Construction subject to change.

Abrir o catálogo na página 10
DSX - 11

Ceiling Slot Diffuser Model Band design for operation with overflow air or dummy plates Additional connecting fishplates In the band design for operation with overflow air or dummy plates, two additional fishplates are supplied loose, thus only requiring two threaded bars on-site for suspension. 04/03 - 11 Construction subject to change. Version: 06.09.2018 No return possible!

Abrir o catálogo na página 11
DSX - 12

Ceiling Slot Diffuser Model End piece (-ES) To give the impression of a surrounding frame, side end pieces can be installed (for an additional charge). These end pieces are supplied loose as standard. If there are order details regarding fitting, mounting will take place at the factory. for DSX-S (-ES1) x End piece on both sides (-ES2 / -ES3) When the end pieces are mounted at the factory, it is essential to specify in the order whether the end piece is to be attached to both sides, or the left- or right-hand side. 04/03 - 12 Construction subject to change. Version: 06.09.2018 No return...

Abrir o catálogo na página 12
DSX - 13

Ceiling Slot Diffuser Model Corner angle (-EW) (1- to 4-slot) Corner angles can only be produced as dummy pieces, i.e., without a plenum box. The corner angle has a 90° angle and is 250 mm long. Other angles are available on request The dummy plate is painted in the colour RAL 9005 (black) or RAL 9010 (white). The corner brackets are supplied loose as standard. DSX-P DSX-PB Fishplate firmly screwed for the on-site connection with slot diffuser + double blade loose 04/03 - 13 Construction subject to change. Version: 06.09.2018 No return possible!

Abrir o catálogo na página 13
DSX - 14

Ceiling Slot Diffuser Model Fastening methods Clamp fastening for DSX-P and DSX-PB in mounting position (not possible for model DSX-S!) Clamp fastening is used for room side installation in finished pressure ceilings. Mounting instructions As standard, the clamp straps are delivered loose. Take out the air guide elements at the ends. Fasten the clamp strap with the screw such that it is positioned in the direction of the slot diffuser (see installation position). Then introduce the slot diffuser into the pressure ceiling. Then rotate the clamp strap by about 90° by rotating the screw and...

Abrir o catálogo na página 14

Todos os catálogos e folhetos técnicos da SCHAKO KG

  1. CNVA

    32 Páginas

  2. AUDIX

    2 Páginas

  3. DISA

    4 Páginas

  4. UC-OH²

    2 Páginas

  5. IGA

    2 Páginas

  6. CDD

    2 Páginas

  7. FBS

    18 Páginas

  8. MINOPAB

    6 Páginas

  9. PIL

    23 Páginas

  10. MWS / MWK

    23 Páginas

  11. ERK-SO

    43 Páginas

  12. BKSYS

    18 Páginas

  13. MINODSA

    6 Páginas

  14. DKA

    6 Páginas

  15. LAQ

    11 Páginas

  16. VMPR/VMPQ

    29 Páginas

  17. BKA-EN

    79 Páginas

  18. CPL

    15 Páginas

  19. AUDIX®

    25 Páginas

  20. VREX

    26 Páginas

  21. VQEX

    17 Páginas

  22. VPEX

    18 Páginas

  23. SVA-FS

    11 Páginas

  24. NRWG

    22 Páginas

  25. COMBIDSC

    26 Páginas

  26. DSCXL

    17 Páginas

  27. DSCU

    18 Páginas

  28. DSCPL

    16 Páginas

  29. DSCP

    15 Páginas

  30. DSC

    37 Páginas

  31. DO

    10 Páginas

  32. VRAQ

    46 Páginas

  33. UEKU

    6 Páginas

  34. UEK

    6 Páginas

  35. SS-K

    6 Páginas

  36. DQJP

    9 Páginas

  37. VOLKOM

    6 Páginas

  38. DQJ

    38 Páginas

  39. ALPETY

    16 Páginas

  40. CTT

    23 Páginas

  41. STV

    8 Páginas

  42. KWB

    19 Páginas

  43. GREENKIT

    20 Páginas

  44. FKU

    31 Páginas

  45. FKF

    29 Páginas

  46. SGA

    5 Páginas

  47. DBB

    27 Páginas

  48. TVO

    8 Páginas

  49. AL

    23 Páginas

  50. SVA-FF

    15 Páginas

  51. NBS

    34 Páginas

  52. MKAR_MKAQ

    13 Páginas

  53. KF

    4 Páginas

  54. JK

    16 Páginas

  55. HK

    16 Páginas

  56. FLAQ

    11 Páginas

  57. FKW

    28 Páginas

  58. FG

    14 Páginas

  59. ERK-MB

    38 Páginas

  60. DISA-H

    34 Páginas

  61. DISA-360

    32 Páginas

  62. DISA-300

    51 Páginas

  63. CNV

    29 Páginas

  64. BKP-EN Fire damper

    40 Páginas

  65. BKA-UE

    35 Páginas

  66. BAK-240

    16 Páginas

  67. Aquaris-Silent

    38 Páginas

  68. Aquaris_KWB

    20 Páginas

  69. DISA-W

    43 Páginas

  70. PILB/PILBR

    33 Páginas

  71. DAV

    19 Páginas

  72. 4DE

    18 Páginas

  73. 4DF

    13 Páginas

  74. DQC

    16 Páginas

  75. DQDL

    16 Páginas

  76. IDA

    21 Páginas

  77. IKA

    23 Páginas

  78. ZMD

    17 Páginas

  79. DQF

    15 Páginas

  80. DQJF

    12 Páginas

  81. DQJA/DQJR

    10 Páginas

  82. DQJSL

    17 Páginas

  83. DQJSLC

    17 Páginas

  84. DHV

    18 Páginas

  85. DSARR

    7 Páginas

  86. QA

    30 Páginas

  87. PUSH

    23 Páginas

  88. WQA

    12 Páginas

  89. DSX-XXL

    23 Páginas

  90. AUDIX®-ÜSG

    13 Páginas

  91. SIA

    7 Páginas

  92. SAR/SAQ/SARP

    13 Páginas

  93. WDA

    32 Páginas

  94. KGRR

    17 Páginas

  95. DBBRR

    11 Páginas

  96. WGARR

    7 Páginas

  97. WGA

    29 Páginas

  98. DKAPPs

    6 Páginas

  99. EBE/EBP

    52 Páginas

  100. VRAPPs

    20 Páginas

  101. VRAR

    52 Páginas

  102. MAK

    15 Páginas

  103. DISA-Family

    4 Páginas

  104. RMS

    11 Páginas

  105. EasyBus

    24 Páginas

  106. TSR

    5 Páginas

  107. RS-F

    7 Páginas

  108. RS

    15 Páginas

  109. VLV

    31 Páginas

  110. VARS

    26 Páginas

  111. VAQS

    19 Páginas

  112. VAS

    26 Páginas

  113. PIANO

    27 Páginas

  114. MBM

    10 Páginas

  115. MBE/MBP

    27 Páginas

  116. DKG

    6 Páginas

  117. ALAS-P

    5 Páginas

  118. ALAS-F 125

    6 Páginas

  119. ALAS

    10 Páginas

  120. ALA-SO

    4 Páginas

  121. ALA-R

    4 Páginas

  122. ALA

    4 Páginas

  123. LL

    7 Páginas

  124. RR-Complete

    41 Páginas

  125. DBBR

    6 Páginas

  126. PA

    32 Páginas

  127. LK

    12 Páginas

  128. IB-R

    15 Páginas

  129. IB-Q

    21 Páginas

  130. KG

    19 Páginas

  131. BSG

    19 Páginas

  132. DSX-XXL-W

    25 Páginas

  133. AUDIX®-AW

    20 Páginas

  134. MINODSX

    6 Páginas

  135. MINODSA

    6 Páginas

  136. DSA

    15 Páginas

  137. COMBIPIL

    11 Páginas

  138. COMBIDQJ

    11 Páginas

  139. MINOPAB

    6 Páginas

  140. BDA

    11 Páginas

  141. SPB

    10 Páginas

  142. CULTRA-Studioline

    24 Páginas

  143. DISA-H

    34 Páginas

  144. DISA-360

    32 Páginas

  145. DISA-300

    51 Páginas

  146. AQUARIS SILENT

    38 Páginas

  147. NBS

    24 Páginas

  148. CNV

    29 Páginas

  149. CNVA

    32 Páginas

  150. JK-LP/JK-LU

    15 Páginas

  151. HKP / HKU

    16 Páginas

  152. FKW

    16 Páginas

  153. FLARE

    13 Páginas

  154. RF

    7 Páginas

  155. KGF

    9 Páginas

  156. SVA-FF

    8 Páginas

  157. BKA-Ü

    35 Páginas

  158. BSK-RPR

    60 Páginas

  159. BKP-EN

    40 Páginas

  160. BAK-240

    6 Páginas

  161. BAK-250

    14 Páginas

  162. KF

    4 Páginas

Catálogos arquivados

  1. DISA-601

    41 Páginas

  2. DISA-B

    32 Páginas