Excertos do catálogo

03/07 - 2 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 2
Models DAV-Q-..., square model NW 400 / 800 DAV-R-..., round model NW 400 / 800 03/07 - 3 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 3
Ceiling Displacement Diffuser DAV Construction Faceplate - perforated sheet steel painted RAL 9010 (white) baffle plate - Sheet steel painted to RAL 9005 (black), only for supply air model Funnel - Sheet steel painted to RAL 9005 (black), only for supply air model Model DAV-Q-... - Square model DAV-R-... - Round model DAV-...-Z-...- Supply air DAV-...-A-...- Return air Accessories Plenum box (SK-R-05-...) - Galvanised sheet steel, with integrated perforated straight-ener (supply air model only) and fixing lugs. Damper (-DK1) - Damper fastening made of plastic - Galvanised sheet steel Damper...
Abrir o catálogo na página 4
Ceiling Displacement Diffuser DAV Models and dimensions DAV-Q-Z-... with SK-R-05-Z -... DAV-R-Z-... with SK-R-05-Z-... DAV-Q-A-... with SK-R-05-A -... DAV-R-A-... with SK-R-05-A -... Inside painted to RAL 9005 (black) Spigot positions KHS= standard height of plenum box Special height = øD + 137 mm, but at least 235 mm 03/07 - 5 Construction subject to change.
Abrir o catálogo na página 5
Ceiling Displacement Diffuser DAV Dimensions of accessories Volumetric flow meter (-VME1)Damper (-DK2), with cable adjustment ball-impact guard (-BS) (only possible for DAV-Q-... with screw mounting and for NW 800 with concealed mounting) Insulation for SK-R-... internal (-Ii) external (-Ia) NW Construction subject to change.
Abrir o catálogo na página 6
Ceiling Displacement Diffuser DAV Fastening methods Screw mounting (-SM) (only DAV-Q-...) for model with ball-impact guard only NW310 with indentation for slotted shallow-raised countersunkhead tapping screw (on-site) Concealed mounting (-VM) In concealed mounting, the ceiling displacement diffuser type DAV-...-Z/A-... is fastened on the plenum box with a pole brace and an M6 cylinder head screw (to DIN EN ISO 4762). 03/07 - 7 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 7
Ceiling Displacement Diffuser DAV Technical data Pressure loss and noise level DAV-...-Z-... for supply air, with plenum box Damper position: 0% = CLOSED 100% = OPEN DAV-...-Z-310-... with SK-R-05-Z-... 03/07 - 8 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 8
Ceiling Displacement Diffuser DAV DAV-...-Z-600/625-... with SK-R-05-Z-... DAV-...-A-... for return air, with plenum box Damper position: 0% = CLOSED 100% = OPEN DAV-...-A-310-... with SK-R-05-A-... Damper position: 0% = CLOSED 100% = OPEN 03/07 - 9 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 9
Ceiling Displacement Diffuser DAV DAV-...-A-400-... with SK-R-05-A-... Damper position: 0% = CLOSED 100% = OPEN 03/07 - 10 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 10
Ceiling Displacement Diffuser DAV Maximum end velocity of jet (isotherm) Correction factor for cooling mode -2 K -4 K -6 K = vmax x 1.05 = vmax x 1.18 = vmax x 1.29 03/07 - 11 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 11
Ceiling Displacement Diffuser DAV Maximum penetration Temperature and induction ratios DAV-...-Z-310-... 03/07 - 12 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 12
Ceiling Displacement Diffuser DAV DAV-...-Z-400-... 03/07 - 13 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 13
Ceiling Displacement Diffuser DAV Propagation diameter Layout example: DAV-...-Z-500-... Mounting height = 4 m VZU = 600 m3/h AT = 4K Required: distance xA (m) xA distance at 600m3/h and AT= 4K = 0.92m Multiply by the corrrection factor of 1.38 (4 m mounting height). xA distance = 0.92 m x 1.38 Result: xA distance = 1.27 m The spacing of the diffusers should be selected such that the jets do not intersect. Construction subject to change.
Abrir o catálogo na página 14
Ceiling Displacement Diffuser DAV Mounting height (m) Supply air volume Supply air volume Return air volume Return air volume Pressure loss A-weighted sound power level Density horizontal throw vertical throw Horizontal + vertical throw Maximum end velocity of jet (vmax = vmittel) Average end velocity of jet Maximum penetration in heating mode Temperature difference between supply air temperature and room temperature (ATo = tZU - tR) Supply air temperature Room temperature Temperature ratio (TV = ATx / ATo) Induction ratio (i = Vx / Vzu) Nominal width Temperature difference at point x total...
Abrir o catálogo na página 15
Ceiling Displacement Diffuser DAV Order code DAV 01 Ceiling displacement diffuser type DAV I square faceplate I supply air I NW500 I faceplate made of sheet steel I faceplate painted to RAL 9010 I drill pattern not reduced I concealed mounting I without ball-impact guard Order details 01 - Type DAV = Ceiling displacement diffuser 02 - Model Q = Square faceplate 03 - Air throw Z = Supply air A = Return air 04 - Nominal size 310 = NW310 400 = NW400 500 = NW500 600 = NW600 625 = NW625 800 = NW800 05 - Material SB = Sheet steel 07 - Drill pattern reduced 000 = Drill pattern not reduced...
Abrir o catálogo na página 16
Ceiling Displacement Diffuser DAV Order code SK 01 Plenum box, square design I for round air diffusers I air diffuser DAV I supply air I NW500 I with concealed mounting I galvanised sheet steel I with damper with cable I with rubber lip seal I with volumetric flow meter I without ROB model I without box insulation I standard height of plenum box I standard spigot diameter I 1 lateral spigot Order details 01 - Plenum box SK = Plenum box, square design 02 - Model R = for round air diffusers with round diffuser support 03 - Air diffuser (must be ordered separately) 05 = suitable for DAV-... 04...
Abrir o catálogo na página 17
Ceiling Displacement Diffuser DAV 13 - Height of plenum box KHS = Height of plenum box standard xxx = Height of plenum box in mm (Heightmin= spigot diameter + 137 mm, but at least 235 mm) 14 - Spigot diameter SDS = Standard spigot diameter xxx = Spigot diameter in mm 15 - Spigot position SO = Spigot from above S1 = lateral spigot on the box (standard) S2 = 2 spigots offset by 90° S3 = 2 spigots offset by 180° S5 = 2 spigots arranged next to each other Construction subject to change.
Abrir o catálogo na página 18Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas