Excertos do catálogo

Technical documentation Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen VRA-Q-E-Ex Volumetric flow controller ATEX
Abrir o catálogo na página 1
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Safety-related notes | Areas of application SAFETY-RELATED NOTES The connection to the electric mains must be performed by a qualified electrician. The transformers used for power supply must meet the requirements according to DIN EN 61558 / VDE 570 part 2-6. A corresponding fuse protection must be available on the mains side. The BKSYS fire damper mini-controller by SCHAKO controls and regulates up to 16 motorised fire dampers (24V AC/DC) or up to 32 fire dampers with a limit switch. The basic module BKSYS-GM1 can be easily extended...
Abrir o catálogo na página 2
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION System components | SYSTEM COMPONENTS EXPANSION MODULE BKSYS-EM1 BASIC MODULE BKSYS-GM1 The power supply of all connected expansion modules and spring return actuators is performed via the basic module BKSYS-GM1. Furthermore, the basic module BKSYS-GM1 controls and regulates the potential-free inputs and outputs, integrates the smoke detectors and forwards the data via the ring buffer and RS232/USB interface to the user. All functions in the basic module BKSYS-GM1 have been designed for maximum simplicity and maximum safety at the...
Abrir o catálogo na página 3
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Configuration CONNECTION SOCKET BKSYS-ADM CONFIGURATION PARAMETERISATION The following configuration parameters can be set using the PC converter BKSYS-USB and the associated PC program. --- Date/Time is taken from the system time of the PC (no automatic switching from daylight saving time to standard time) --- potential-free fault input (smoke detector) --- for the connection of the spring return actuator 24V AC/DC --- with connection for the plugs (power supply and limit switch) of the spring return actuator 24V AC/DC ---...
Abrir o catálogo na página 4
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Configuration FUNCTIONAL TEST The test run serves for functional check of the connected spring return actuators. One button each on the BKSYS basic and expansion modules is used to start the functional test. The spring return actuators assigned to the corresponding basic or expansion module close the fire dampers. After reaching the Closed position, the spring return actuators open the fire dampers again. During this functional test, the LEDs assigned to the spring return actuators are flashing. The same functional test can also be...
Abrir o catálogo na página 5
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Technical data | Assembly TECHNICAL DATA PERFORMANCE DATA Rated voltage: 24 V AC/DC +- 15% Current consumption: max. 3600 mA Power consumption per module: 5 VA Ambient temperature: 0°….. +55°C Storage temperature: (-) 20° to (+) 60°C Humidity: max. 80% relative, non-condensing The basic module BKSYS-GM1 and expansion modules BKSYSEM1 are mounted on the existing DIN rails and connected to each other using Plug and Play plug-in connection. The power supply for the expansion modules BKSYS-EM1 is performed via the basic module BKSYS-GM1....
Abrir o catálogo na página 6
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Commissioning sion modules BKSYS-EM1 (terminal X2 to BKSYS-GM1 and terminal X1 to BKSYS-EM1). If a smoke detector triggers an alarm, then this command is limited only to the connected module. Thus, only the motorised fire dampers connected to the corresponding module will be closed. TERMINAL ASSIGNMENT OF EXPANSION MODULE BKSYS-EM1 08. Select the setting in the ALARM DELAY checkbox: The set time indicates how long the fault output is disabled for maintenance purposes. Once the time has elapsed, the set value is reset to 0 minutes....
Abrir o catálogo na página 7
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Connection diagrams | CONNECTION DIAGRAMS CONNECTION OF BASIC MODULE BKSYS-GM1 CONNECTION 24 V AC/DC feed Smoke detector (RM) input Connection socket BKSYS-ADM for spring return actuators Mechanical fire damper with 2 limit switches (zero-current CLOSED) Voltage output 24 V AC/DC PC interface USB-RS232 Voltage output 24 V AC/DC Fan input Fault output (changeover contact) One mechanical fire damper with one limit switch Two mechanical fire dampers with one limit switch MOTOR CONNECTION SOCKET BKSYS-ADM Construction subject to change...
Abrir o catálogo na página 8
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Order code | Specification text ORDER CODE SPECIFICATION TEXT ORDER DETAILS Fire damper mini-controller BKSYS Product SCHAKO KG Fire damper mini-controller BKSYS for control and display of fire damper actuators and limit switches consisting of: Basic module Expansion module Interface adapter from USB to RS232 (serial) Connection socket for motorised actuators Modbus interface microprocessor-controlled with real-time clock, gold cap and ring buffer for control and display of up to: --- four motorised fire dampers with 24 V AC/DC...
Abrir o catálogo na página 9
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Order code | Specification text Connection socket BKSYS-ADM according to degree of protection IP 66 Housing: Stable sheet steel construction consisting of 1.25 mm or 1.5 mm sheet steel, canted and welded from a single piece, with circumferential protective channel at the door opening, rear wall with countersunk bores for wall mounting support. Housing bottom with sheet steel flange plates. All modules are completely preassembled and prewired on terminal blocks. Maximum size: 2x GM1 + 6xEM1 Dimensions (W x H x D): 800 x 600 x 300 mm...
Abrir o catálogo na página 10
Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Appendix Part 1 Modbus Interface | APPENDIX PART 1 MODBUS INTERFACE A transmitted message always contains all status information of exactly one module and the current system time. MODBUS CONFIGURATION The Modbus configuration must be set before initialisation and cannot be changed during operation. CONNECTIONS AND CONFIGURATIONS Switch for setting the unique address (hexadecimal) SETTING THE MODBUS ADDRESS Each Modbus slave requires a unique address in the allowed address space of 1 - 247 (decimal). The address 0 is reserved for...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas