BKSYS - 1

Technical documentation Technical documentation SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen VRA-Q-E-Ex Volumetric flow controller ATEX

Abrir o catálogo na página 1
BKSYS - 2

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Safety-related notes | Areas of application SAFETY-RELATED NOTES The connection to the electric mains must be performed by a qualified electrician. The transformers used for power supply must meet the requirements according to DIN EN 61558 / VDE 570 part 2-6. A corresponding fuse protection must be available on the mains side. The BKSYS fire damper mini-controller by SCHAKO controls and regulates up to 16 motorised fire dampers (24V AC/DC) or up to 32 fire dampers with a limit switch. The basic module BKSYS-GM1 can be easily extended...

Abrir o catálogo na página 2
BKSYS - 3

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION System components | SYSTEM COMPONENTS EXPANSION MODULE BKSYS-EM1 BASIC MODULE BKSYS-GM1 The power supply of all connected expansion modules and spring return actuators is performed via the basic module BKSYS-GM1. Furthermore, the basic module BKSYS-GM1 controls and regulates the potential-free inputs and outputs, integrates the smoke detectors and forwards the data via the ring buffer and RS232/USB interface to the user. All functions in the basic module BKSYS-GM1 have been designed for maximum simplicity and maximum safety at the...

Abrir o catálogo na página 3
BKSYS - 4

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Configuration CONNECTION SOCKET BKSYS-ADM CONFIGURATION PARAMETERISATION The following configuration parameters can be set using the PC converter BKSYS-USB and the associated PC program. --- Date/Time is taken from the system time of the PC (no automatic switching from daylight saving time to standard time) --- potential-free fault input (smoke detector) --- for the connection of the spring return actuator 24V AC/DC --- with connection for the plugs (power supply and limit switch) of the spring return actuator 24V AC/DC ---...

Abrir o catálogo na página 4
BKSYS - 5

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Configuration FUNCTIONAL TEST The test run serves for functional check of the connected spring return actuators. One button each on the BKSYS basic and expansion modules is used to start the functional test. The spring return actuators assigned to the corresponding basic or expansion module close the fire dampers. After reaching the Closed position, the spring return actuators open the fire dampers again. During this functional test, the LEDs assigned to the spring return actuators are flashing. The same functional test can also be...

Abrir o catálogo na página 5
BKSYS - 6

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Technical data | Assembly TECHNICAL DATA PERFORMANCE DATA Rated voltage: 24 V AC/DC +- 15% Current consumption: max. 3600 mA Power consumption per module: 5 VA Ambient temperature: 0°….. +55°C Storage temperature: (-) 20° to (+) 60°C Humidity: max. 80% relative, non-condensing The basic module BKSYS-GM1 and expansion modules BKSYSEM1 are mounted on the existing DIN rails and connected to each other using Plug and Play plug-in connection. The power supply for the expansion modules BKSYS-EM1 is performed via the basic module BKSYS-GM1....

Abrir o catálogo na página 6
BKSYS - 7

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION | Commissioning sion modules BKSYS-EM1 (terminal X2 to BKSYS-GM1 and terminal X1 to BKSYS-EM1). If a smoke detector triggers an alarm, then this command is limited only to the connected module. Thus, only the motorised fire dampers connected to the corresponding module will be closed. TERMINAL ASSIGNMENT OF EXPANSION MODULE BKSYS-EM1 08. Select the setting in the ALARM DELAY checkbox: The set time indicates how long the fault output is disabled for maintenance purposes. Once the time has elapsed, the set value is reset to 0 minutes....

Abrir o catálogo na página 7
BKSYS - 8

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Connection diagrams | CONNECTION DIAGRAMS CONNECTION OF BASIC MODULE BKSYS-GM1 CONNECTION 24 V AC/DC feed Smoke detector (RM) input Connection socket BKSYS-ADM for spring return actuators Mechanical fire damper with 2 limit switches (zero-current CLOSED) Voltage output 24 V AC/DC PC interface USB-RS232 Voltage output 24 V AC/DC Fan input Fault output (changeover contact) One mechanical fire damper with one limit switch Two mechanical fire dampers with one limit switch MOTOR CONNECTION SOCKET BKSYS-ADM Construction subject to change...

Abrir o catálogo na página 8
BKSYS - 9

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Order code | Specification text ORDER CODE SPECIFICATION TEXT ORDER DETAILS Fire damper mini-controller BKSYS Product SCHAKO KG Fire damper mini-controller BKSYS for control and display of fire damper actuators and limit switches consisting of: Basic module Expansion module Interface adapter from USB to RS232 (serial) Connection socket for motorised actuators Modbus interface microprocessor-controlled with real-time clock, gold cap and ring buffer for control and display of up to: --- four motorised fire dampers with 24 V AC/DC...

Abrir o catálogo na página 9
BKSYS - 10

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Order code | Specification text Connection socket BKSYS-ADM according to degree of protection IP 66 Housing: Stable sheet steel construction consisting of 1.25 mm or 1.5 mm sheet steel, canted and welded from a single piece, with circumferential protective channel at the door opening, rear wall with countersunk bores for wall mounting support. Housing bottom with sheet steel flange plates. All modules are completely preassembled and prewired on terminal blocks. Maximum size: 2x GM1 + 6xEM1 Dimensions (W x H x D): 800 x 600 x 300 mm...

Abrir o catálogo na página 10
BKSYS - 11

Fire damper mini-controller BKSYS TECHNICAL DOCUMENTATION Appendix Part 1 Modbus Interface | APPENDIX PART 1 MODBUS INTERFACE A transmitted message always contains all status information of exactly one module and the current system time. MODBUS CONFIGURATION The Modbus configuration must be set before initialisation and cannot be changed during operation. CONNECTIONS AND CONFIGURATIONS Switch for setting the unique address (hexadecimal) SETTING THE MODBUS ADDRESS Each Modbus slave requires a unique address in the allowed address space of 1 - 247 (decimal). The address 0 is reserved for...

Abrir o catálogo na página 11

Todos os catálogos e folhetos técnicos da SCHAKO KG

  1. CNVA

    32 Páginas

  2. AUDIX

    2 Páginas

  3. DISA

    4 Páginas

  4. UC-OH²

    2 Páginas

  5. IGA

    2 Páginas

  6. CDD

    2 Páginas

  7. FBS

    18 Páginas

  8. MINOPAB

    6 Páginas

  9. PIL

    23 Páginas

  10. MWS / MWK

    23 Páginas

  11. ERK-SO

    43 Páginas

  12. MINODSA

    6 Páginas

  13. DKA

    6 Páginas

  14. LAQ

    11 Páginas

  15. VMPR/VMPQ

    29 Páginas

  16. BKA-EN

    79 Páginas

  17. CPL

    15 Páginas

  18. AUDIX®

    25 Páginas

  19. VREX

    26 Páginas

  20. VQEX

    17 Páginas

  21. VPEX

    18 Páginas

  22. SVA-FS

    11 Páginas

  23. NRWG

    22 Páginas

  24. COMBIDSC

    26 Páginas

  25. DSCXL

    17 Páginas

  26. DSCU

    18 Páginas

  27. DSCPL

    16 Páginas

  28. DSCP

    15 Páginas

  29. DSC

    37 Páginas

  30. DO

    10 Páginas

  31. VRAQ

    46 Páginas

  32. UEKU

    6 Páginas

  33. UEK

    6 Páginas

  34. SS-K

    6 Páginas

  35. DQJP

    9 Páginas

  36. VOLKOM

    6 Páginas

  37. DQJ

    38 Páginas

  38. ALPETY

    16 Páginas

  39. CTT

    23 Páginas

  40. STV

    8 Páginas

  41. KWB

    19 Páginas

  42. GREENKIT

    20 Páginas

  43. FKU

    31 Páginas

  44. FKF

    29 Páginas

  45. SGA

    5 Páginas

  46. DBB

    27 Páginas

  47. TVO

    8 Páginas

  48. AL

    23 Páginas

  49. SVA-FF

    15 Páginas

  50. NBS

    34 Páginas

  51. MKAR_MKAQ

    13 Páginas

  52. KF

    4 Páginas

  53. JK

    16 Páginas

  54. HK

    16 Páginas

  55. FLAQ

    11 Páginas

  56. FKW

    28 Páginas

  57. FG

    14 Páginas

  58. ERK-MB

    38 Páginas

  59. DISA-H

    34 Páginas

  60. DISA-360

    32 Páginas

  61. DISA-300

    51 Páginas

  62. CNV

    29 Páginas

  63. BKP-EN Fire damper

    40 Páginas

  64. BKA-UE

    35 Páginas

  65. BAK-240

    16 Páginas

  66. Aquaris-Silent

    38 Páginas

  67. Aquaris_KWB

    20 Páginas

  68. DISA-W

    43 Páginas

  69. PILB/PILBR

    33 Páginas

  70. DAV

    19 Páginas

  71. 4DE

    18 Páginas

  72. 4DF

    13 Páginas

  73. DQC

    16 Páginas

  74. DQDL

    16 Páginas

  75. IDA

    21 Páginas

  76. IKA

    23 Páginas

  77. ZMD

    17 Páginas

  78. DQF

    15 Páginas

  79. DQJF

    12 Páginas

  80. DQJA/DQJR

    10 Páginas

  81. DQJSL

    17 Páginas

  82. DQJSLC

    17 Páginas

  83. DHV

    18 Páginas

  84. DSARR

    7 Páginas

  85. QA

    30 Páginas

  86. PUSH

    23 Páginas

  87. WQA

    12 Páginas

  88. DSX-XXL

    23 Páginas

  89. AUDIX®-ÜSG

    13 Páginas

  90. SIA

    7 Páginas

  91. SAR/SAQ/SARP

    13 Páginas

  92. WDA

    32 Páginas

  93. KGRR

    17 Páginas

  94. DBBRR

    11 Páginas

  95. WGARR

    7 Páginas

  96. WGA

    29 Páginas

  97. DKAPPs

    6 Páginas

  98. EBE/EBP

    52 Páginas

  99. VRAPPs

    20 Páginas

  100. VRAR

    52 Páginas

  101. MAK

    15 Páginas

  102. DISA-Family

    4 Páginas

  103. RMS

    11 Páginas

  104. EasyBus

    24 Páginas

  105. TSR

    5 Páginas

  106. RS-F

    7 Páginas

  107. RS

    15 Páginas

  108. VLV

    31 Páginas

  109. VARS

    26 Páginas

  110. VAQS

    19 Páginas

  111. VAS

    26 Páginas

  112. PIANO

    27 Páginas

  113. MBM

    10 Páginas

  114. MBE/MBP

    27 Páginas

  115. DKG

    6 Páginas

  116. ALAS-P

    5 Páginas

  117. ALAS-F 125

    6 Páginas

  118. ALAS

    10 Páginas

  119. ALA-SO

    4 Páginas

  120. ALA-R

    4 Páginas

  121. ALA

    4 Páginas

  122. LL

    7 Páginas

  123. RR-Complete

    41 Páginas

  124. DBBR

    6 Páginas

  125. PA

    32 Páginas

  126. LK

    12 Páginas

  127. IB-R

    15 Páginas

  128. IB-Q

    21 Páginas

  129. KG

    19 Páginas

  130. BSG

    19 Páginas

  131. DSX-XXL-W

    25 Páginas

  132. AUDIX®-AW

    20 Páginas

  133. DSX

    25 Páginas

  134. MINODSX

    6 Páginas

  135. MINODSA

    6 Páginas

  136. DSA

    15 Páginas

  137. COMBIPIL

    11 Páginas

  138. COMBIDQJ

    11 Páginas

  139. MINOPAB

    6 Páginas

  140. BDA

    11 Páginas

  141. SPB

    10 Páginas

  142. CULTRA-Studioline

    24 Páginas

  143. DISA-H

    34 Páginas

  144. DISA-360

    32 Páginas

  145. DISA-300

    51 Páginas

  146. AQUARIS SILENT

    38 Páginas

  147. NBS

    24 Páginas

  148. CNV

    29 Páginas

  149. CNVA

    32 Páginas

  150. JK-LP/JK-LU

    15 Páginas

  151. HKP / HKU

    16 Páginas

  152. FKW

    16 Páginas

  153. FLARE

    13 Páginas

  154. RF

    7 Páginas

  155. KGF

    9 Páginas

  156. SVA-FF

    8 Páginas

  157. BKA-Ü

    35 Páginas

  158. BSK-RPR

    60 Páginas

  159. BKP-EN

    40 Páginas

  160. BAK-240

    6 Páginas

  161. BAK-250

    14 Páginas

  162. KF

    4 Páginas

Catálogos arquivados

  1. DISA-601

    41 Páginas

  2. DISA-B

    32 Páginas