Fire-resistant damper model BKA-Ü Technical documentation Description DESCRIPTION Fire-resistant dampers of special design and use are used if, as part of ventilation planning, openings are required in fireresistant inner walls or ceilings for the air intake, they must be closed in the event of a fire. The competent building supervisory authority will decide whether the opening is admissible, for example because it differs or in connection with the approval of the fire protection concept. The required dampers are fire-resistant dampers which are closed in case of fire driven by a suitable...
Abrir o catálogo na página 2
ichAkoIFire-resistant damper model BKA-U Technical documentation Models and dimensionsMODELS AND DIMENSIONSDimensions Legend Width Height Length Density at least maximum or approximately Utility company Version: 2015-08-17 | Document: 09/20 | Page 3 Construction subject to change No return possible 1 Fire damper BKA-EN (component of BKA-U) Assembly part type EBT Extension piece type VT Finishing protective grating type ASG Electric spring return actuator 24 V Smoke detector RMSII-L Protective cover
Abrir o catálogo na página 3
vchAko Fire-resistant damper model BKA-U Technical documentation Models and dimensions Table 1: Available sizes Available at an extra charge • All heights and widths which can be combined are available! • Drive unit always on the H side of the fire damper. • Inspection openings always on the B side of the fire damper. • On request, the width and height dimensions are available in steps of 10 mm. • For wall installation, the smoke detector must always be installed above in the assembly part type EBT with the damper blade axle in the horizontal position. • Stainless steel model with material...
Abrir o catálogo na página 4
ichAkoIFire-resistant damper model BKA-U Technical documentation Models and dimensionsUse The fire-resistant damper BKA-U can be installed according to the following table. Even considering the installation of the dampers in walls and ceilings mentioned above, they still meet the requirements of the corresponding fire resistance class (resistance duration 90 minutes). 11 For wall installation, the smoke detector must always be installed above in the assembly part type EBT with the damper blade axle in the horizontal position. 2) When installing in solid ceilings, the dimensions of the...
Abrir o catálogo na página 5
Fire-resistant damper model BKA-Ü Technical documentation Installation details Risk of injuries during mounting or installation. To avoid any possible injuries, personal protective equipment (PPE) must be worn. Fire-resistant dampers must be installed such that external forces do not impair their continuous functioning. During mounting, it may be necessary to provide reinforcements for the housing or the like. The requirement of statically load-bearing lintels has to be considered. Improper transport/handling may result in damage/functional impairment. Furthermore, the film of the transport...
Abrir o catálogo na página 6
Fire-resistant damper model BKA-Ü Technical documentation Installation details Minimum gap size with complete mortar lining Installation with partial mortar lining Installation of the fire-resistant damper in an existing wall recess or a wall recess to be constructed. It has to be designed in such a way that the minimum gap size between the housing and solid wall smin is 40 mm (maximum gap size smax ≤ 60 mm). The gap "s" must be completely filled with mortar of category M2.5 to M15 to EN 998-2, NM II to III DIN V 18580 (previously: MG II to III to DIN 1053) or fire protection mortar of...
Abrir o catálogo na página 7
Fire-resistant damper model BKA-Ü Technical documentation Installation details Installation in solid ceilings Installation in solid ceilings made, for example, of concrete, aerated concrete, apparent density ≥ 500 kg/m³ and ceiling thickness D ≥ 125 mm. When installing in solid ceilings, the dimensions of the fireresistant damper BKA-Ü are limited to W and H = 500 mm. Installation of no more than 2 BKA-Üs next to each other "flange-to-flange" without clearance in solid walls. The circumferential gaps and the gap between the housing of BKA-Ü must be filled completely to the minimum...
Abrir o catálogo na página 8
Fire-resistant damper model BKA-Ü Technical documentation Installation details Installation in lightweight partition walls with metal posts and panelling on both sides Wet installation (circumferential mortar lining) Installation without mounting frame ER in lightweight partition walls with metal posts and panelling on both sides (gypsum-bonded wall boards; wall thickness W≥ 100 mm) as classified according to EN 13501-2 or comparable national standards. No additional, permanent suspensions or attachments of BKA-Ü are allowed, and installation and mounting aids must be removed. The...
Abrir o catálogo na página 9
Fire-resistant damper model BKA-Ü Technical documentation Installation details Installation procedure Mount the metal posts and the wall according to the specifications of the wall manufacturer and the required spare parts as shown in Figure 7. Provide a recess for the wet installation of BKA-Ü (pos. 1) On both B sides of the exchange profiles (in ⅓ of the points), 2 bent perforated plates each (t ≥ 0.5 mm; width x length = 40 x 70 mm), must be fastened as mortar anchor (pos. 14). They must be screwed to the metal profiles in the wall centre, using one dry-wall screw each, and cast in...
Abrir o catálogo na página 10
Fire-resistant damper model BKA-Ü Technical documentation Installation details Installation procedure The general information regarding installation without mounting frame ER in lightweight partition walls with metal posts and panelling on both sides (gypsum-bonded wall boards; wall thickness W≥ 100 mm) as classified according to EN 13501-2 or comparable national standards must be observed. Mount the metal posts of the wall in accordance with the specifications of the wall manufacturer and the required spare parts as shown in Figure 7. Insert BKA-Ü (pos. 1) into the wall recess...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas