Excertos do catálogo

11/06 - 2 Construction subject to change. Version: 08.12.2009 No return possible!
Abrir o catálogo na página 2
Ceiling Cooling System Alpety Description Knowledge of the direct correlation between human productivity and ambient conditions, for example room temperature and air humidity, leads to an increased use of technology for cooling, humidifying or dehumidifying. According to DIN 1946 Part 2, at high outside temperatures in summer and short appearances of high thermal loads, an increase in the operative room temperature is allowed. Often the cooling load of rooms is not determined by outside but inside thermal loads. If these loads appear for short periods only, the operative room temperature is...
Abrir o catálogo na página 3
Ceiling Cooling System Alpety The overall system is checked for tightness on-site. The maximum test pressure is 10 bar. This check is carried out by the pressure-drop method. As with all cooling ceilings, the cold water supply temperature must be selected such that it will not drop below the dew point. A combination with twist or slot diffusers as well as lights is possible. Attention: The Alpety cooling ceiling elements must be designed and installed in such a way that a condensate-free operation is guaranteed. Upon request, the ceiling panels to be activated can be provided. If ceiling...
Abrir o catálogo na página 4
Ceiling Cooling System Alpety Model Alpety-SKS-R Alpety-SKS-Q Alpety-SKS-...-A (available at an extra charge) - Rectangular shaped ceiling panel - Square ceiling panels - Aluminium sheet ceiling panels, powdercoated to RAL 9010 (white) Alpety-SKS-...-S - Galvanised sheet steel ceiling panels, powder-coated to RAL 9010 (white) Alpety-SKS-...-...-O - without perforation and without acoustic fleece Alpety-SKS-...-...-P - with standard perforation of Ø 2.5 mm and 16% free cross-section and with black acoustic fleece, thermally glued all over (white fleece on request) Alpety-FKL - Blade cooling...
Abrir o catálogo na página 5
Alpety-SKS-R: Rectangular shaped ceiling panel L= from 800 to 2500 mm W= from 200 to 800 mm (in intervals of 100 mm) Other dimensions on request Alpety-SKS-Q: Square ceiling panels Length x Width 600x600 625x625 700x700 800x800 900x900 Other dimensions on request The panel thickness and bevel depend on the selected ceiling system. Output Cooling power to DIN 4715: up to 90 W/m2 The cooling power of the cooling ceiling elements depends on the type of air supply as well as the covered %, i.e., percentage of the activated surface area, relative to the overall surface area of the ceiling....
Abrir o catálogo na página 6
Ceiling Cooling System Alpety Cooling ceiling blade types Adjusted to the requirements of the architect or client Alpety-FKL 134 Determination of the cooling capacity to DIN 14 240 Average temperature difference Room temperature Water supply temperature Water return temperature When combined with a ventilation system with turbulent supply air pattern (air change rate of at least 2), the performance data from the performance tables are increased by up to 10 %. When combined with a laminar supply air pattern (air change rate of at least 2), the performance data from the performance tables are...
Abrir o catálogo na página 7
Average temperature difference Room temperature Water supply temperature Water return temperature When combined with a ventilation system with turbulent supply air pattern (air change rate of at least 2), the performance data from the performance tables are increased by up to 10 %. When combined with a laminar supply air pattern (air change rate of at least 2), the performance data from the performance tables are increased by up to 5%. Construction subject to change.
Abrir o catálogo na página 8
Available sizes for Alpety FKL / HKL Suspended ceiling fixture: Detail X Cooling sails Alpety FKL / HKL Alpety FKL/HKL are joined to give two- to six-blade cooling sails having a maximum length of 2500 mm. Note: The cooling sails are connected to one another with flexible hoses. Make sure that the hoses are connected without kinks. Alpety-FKL Construction subject to change.
Abrir o catálogo na página 9
Ceiling Cooling System Alpety Technical Data Control of cooling ceilings The output of cooling ceilings is usually controlled by varying the water flow of the cooling ceiling. A stop valve having a thermal or motorised actuator, which varies the amount of flow as a function of ambient temperature, is suitable for this. Hydraulic connection scheme of the cooling ceiling Supply Dew point control A condensation of the cooling ceiling will take place when the surface temperature of the cooling ceiling falls below the dew point temperature of the room. Single-room dew point control - passive The...
Abrir o catálogo na página 10
Ceiling Cooling System Alpety Central temperature control including dew point control per single room - active The supply temperature for the cooling ceiling is controlled centrally as a function of the dew point temperature of the return air or of a reference room. The room cooling is not interrupted. 11/06 - 11 Construction subject to change. Version: 08.12.2009 No return possible!
Abrir o catálogo na página 11
Ceiling Cooling System Alpety Control examples Standard solution for single rooms Cooling ceiling Function: Passive dew point control by connecting a dew point sensor type QXA 2000, AQX 2000. Construction subject to change.
Abrir o catálogo na página 12
Ceiling Cooling System Alpety Bus-capable single-room control Konnex EIB or LON Cooling / Heating (in sequences), cooling ceiling with radiator heating Selection of units: KONNEX - EIB Function - Passive dew point control by means of dew point sensor QXA 2000 - Communication-capable controller - Comfort, Standby, Energy Cutoff temperature level Construction subject to change.
Abrir o catálogo na página 13
Ceiling Cooling System Alpety Further data Questionnaire for planning cooling or heating ceilings Sound absorption requirements: at Project / Place: __________________________________ Type of ventilation system Floor surface area per person ___ Turbulent ventilation via swirl or slot diffusers internal load per m² (persons, lighting, EDP, etc.) ___ Displacement ventilation via floor or displacement ventilation outlets external load per m² (radiation and heat transfer) Room division: ___ Large room ___ Single rooms with fixed partition walls ___ Cooling only ___ Single rooms with adjustable...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
4DF
13 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas