Excertos do catálogo

05/09 - 2 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 2
Ceiling diffuser 4DF Description The square ceiling diffuser type 4DF with fixed air deflection blades is suitable for use in supply and return air systems. The supply air is delivered horizontally in four directions. The air diffuser is fitted flush to the ceiling The construction of the faceplate allows easy cleaning. A volumetric flow meter can be integrated into the spigot of the plenum box at an extra charge. The measurement error of the volumetric flow meter is ± 5 % at a connection spigot velocity of 2-5 m/s and a straight flow pattern of at least 1 x D. The measurement is carried...
Abrir o catálogo na página 3
Ceiling diffuser 4DF Models and dimensions Dimensions 4DF with SK-Q-07-Z-... (for supply air, with concealed mounting) 4DF with SK-Q-07-A-... (for return air, with concealed mounting) KHS= standard height of plenum box Special height of plenum box = øD + 102mm, but at least 200mm Spigot positions 05/09 - 4 Construction subject to change. Version: 20.09.2019 No return possible
Abrir o catálogo na página 4
Ceiling diffuser 4DF Accessories - dimensions (at an extra charge): Volumetric flow meter (-VME1) Fastening methods Screw mounting (-SM) only for connection to fire protection unit NW 310 with indentation for slotted shallow-raised countersunkhead tapping screw (on-site) - NW 310: DIN ISO 7051 pitch 3.9 - NW 400-625: DIN ISO 7051 pitch 4.8 Rubber lip seal (-GD1) Detail X 05/09 - 5 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 5
Ceiling diffuser 4DF Technical data Pressure loss and noise level Supply air with plenum box Construction subject to change.
Abrir o catálogo na página 6
Ceiling diffuser 4DF Return air with plenum box Damper position OPEN in % 4DF-A-310-... with SK-Q-07-A-... 05/09 - 7 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 7
Ceiling diffuser 4DF Maximum end velocity of jet with plenum box 4DF-Z-400-... 05/09 - 8 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 8
Ceiling diffuser 4DF Critical throw 4DF-Z-400-... 05/09 - 9 Construction subject to change. Version: 20.09.2019 No return possible!
Abrir o catálogo na página 9
Induction ratios Temperature ratios Legend Vzu (m3/h) Vzu [l/s] Vab (m3/h) Vab [l/s] Apt (Pa) Lwa [dB(A)] P (kg/m3) vmax (m/s) v (m/s) x+y (m) Xkr (m) ATo (K) tzu (K) tR (K) i (-) tv (-) NW (mm) ATx (K) Vx (m3/h) Supply air volume Supply air volume Return air volume Return air volume Pressure loss A-weighted sound power level Density Maximum end velocity of jet Average end velocity of jet (v = vmax x 0.5) Horizontal + vertical throw Critical jet path Temperature difference between supply air temperature and room temperature (aTo = tZU - tR) Supply air temperature Room temperature Induction...
Abrir o catálogo na página 10
Ceiling diffuser 4DF Order details 4DF 01 Sample 4DF-Z-500-SB-9010-VM Ceiling diffuser type 4DF I supply air I NW500 I faceplate made of sheet steel I faceplate painted to RAL9010 I concealed mounting Order details 01 - Type 4DF = Ceiling diffuser 02 - Air throw Z = Supply air A = Return air 03 - Nominal size 310 = NW310 400 = NW400 500 = NW500 600 = NW600 625 = NW625 04 - Material SB = Sheet steel (standard) AL = Aluminium (only available with VM) 05 - Paint 9010 = RAL colour white (standard) xxxx = RAL colour can be freely selected ELOX = Natural colour anodised (only for AL) 06 -...
Abrir o catálogo na página 11
Ceiling diffuser 4DF Order details SK 01 Sample SK-Q-07-Z-500-VM-SV-DK1-GD1-VME1-ROB0-I0-KHS-SDS-S1 Plenum box, square design I for square air diffusers I ceiling diffuser 4DF I supply air I NW500 I with concealed mounting I galvanised sheet steel I with damper I with rubber lip seal I with volumetric flow meter I without ROB model I without box insulation I standard height of plenum box I standard spigot diameter I 1 lateral spigot Order details 01 - Plenum box 07 - Material SK = Plenum box, square design SV = Galvanised sheet steel (standard) 02 - Model Q = for square air diffusers 03 -...
Abrir o catálogo na página 12
Ceiling diffuser 4DF 13 - Height of plenum box KHS = Height of plenum box standard xxx = Height of plenum box in mm (Heightmin = spigot diameter +102 mm, but at least 200 mm) 14 - Spigot diameter SDS = Standard spigot diameter xxx = Spigot diameter in mm 15 - Spigot position S0 = Spigot from above S1 = 1 lateral spigot on the box (standard) S2 = 2 spigots offset by 90° S3 = 2 spigots offset by 180° S5 = 2 spigots arranged next to each other Specification texts Ceiling diffuser type 4DF for supply and return air, horizontal throw in 4 directions. Particularly suitable for installation in...
Abrir o catálogo na página 13Todos os catálogos e folhetos técnicos da SCHAKO KG
-
CNVA
32 Páginas
-
KGF Compact Filter Grille
9 Páginas
-
AUDIX
2 Páginas
-
DISA
4 Páginas
-
UC-OH²
2 Páginas
-
IGA
2 Páginas
-
CDD
2 Páginas
-
FBS
18 Páginas
-
MINOPAB
6 Páginas
-
PIL
23 Páginas
-
MWS / MWK
23 Páginas
-
ERK-SO
43 Páginas
-
BKSYS
18 Páginas
-
MINODSA
6 Páginas
-
DKA
6 Páginas
-
LAQ
11 Páginas
-
VMPR/VMPQ
29 Páginas
-
BKA-EN
79 Páginas
-
CPL
15 Páginas
-
AUDIX®
25 Páginas
-
VREX
26 Páginas
-
VQEX
17 Páginas
-
VPEX
18 Páginas
-
SVA-FS
11 Páginas
-
NRWG
22 Páginas
-
COMBIDSC
26 Páginas
-
DSCXL
17 Páginas
-
DSCU
18 Páginas
-
DSCPL
16 Páginas
-
DSCP
15 Páginas
-
DSC
37 Páginas
-
DO
10 Páginas
-
VRAQ
46 Páginas
-
UEKU
6 Páginas
-
UEK
6 Páginas
-
SS-K
6 Páginas
-
DQJP
9 Páginas
-
VOLKOM
6 Páginas
-
DQJ
38 Páginas
-
ALPETY
16 Páginas
-
CTT
23 Páginas
-
STV
8 Páginas
-
KWB
19 Páginas
-
GREENKIT
20 Páginas
-
FKU
31 Páginas
-
FKF
29 Páginas
-
SGA
5 Páginas
-
DBB
27 Páginas
-
TVO
8 Páginas
-
AL
23 Páginas
-
SVA-FF
15 Páginas
-
RF Return air filter grille
7 Páginas
-
NBS
34 Páginas
-
MKAR_MKAQ
13 Páginas
-
KF
4 Páginas
-
JK
16 Páginas
-
HK
16 Páginas
-
Lint Separator FLARE
13 Páginas
-
FLAQ
11 Páginas
-
FKW
28 Páginas
-
FG
14 Páginas
-
ERK-MB
38 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
CNV
29 Páginas
-
BKP-EN Fire damper
40 Páginas
-
BKA-UE
35 Páginas
-
BAK-250 Fire protection unit
17 Páginas
-
BAK-240
16 Páginas
-
Aquaris-Silent
38 Páginas
-
Aquaris_KWB
20 Páginas
-
DISA-W
43 Páginas
-
PILB/PILBR
33 Páginas
-
DAV
19 Páginas
-
4DE
18 Páginas
-
DQC
16 Páginas
-
DQDL
16 Páginas
-
IDA
21 Páginas
-
IKA
23 Páginas
-
ZMD
17 Páginas
-
DQF
15 Páginas
-
DQJF
12 Páginas
-
DQJA/DQJR
10 Páginas
-
DQJSL
17 Páginas
-
DQJSLC
17 Páginas
-
DHV
18 Páginas
-
DSARR
7 Páginas
-
QA
30 Páginas
-
PUSH
23 Páginas
-
WQA
12 Páginas
-
DSX-XXL
23 Páginas
-
AUDIX®-ÜSG
13 Páginas
-
SIA
7 Páginas
-
SAR/SAQ/SARP
13 Páginas
-
WDA
32 Páginas
-
KGRR
17 Páginas
-
DBBRR
11 Páginas
-
WGARR
7 Páginas
-
WGA
29 Páginas
-
DKAPPs
6 Páginas
-
EBE/EBP
52 Páginas
-
VRAPPs
20 Páginas
-
VRAR
52 Páginas
-
MAK
15 Páginas
-
DISA-Family
4 Páginas
-
RMS
11 Páginas
-
EasyBus
24 Páginas
-
TSR
5 Páginas
-
RS-F
7 Páginas
-
RS
15 Páginas
-
VLV
31 Páginas
-
VARS
26 Páginas
-
VAQS
19 Páginas
-
VAS
26 Páginas
-
PIANO
27 Páginas
-
MBM
10 Páginas
-
MBE/MBP
27 Páginas
-
DKG
6 Páginas
-
ALAS-P
5 Páginas
-
ALAS-F 125
6 Páginas
-
ALAS
10 Páginas
-
ALA-SO
4 Páginas
-
ALA-R
4 Páginas
-
ALA
4 Páginas
-
LL
7 Páginas
-
RR-Complete
41 Páginas
-
DBBR
6 Páginas
-
PA
32 Páginas
-
LK
12 Páginas
-
IB-R
15 Páginas
-
IB-Q
21 Páginas
-
KG
19 Páginas
-
BSG
19 Páginas
-
DSX-XXL-W
25 Páginas
-
AUDIX®-AW
20 Páginas
-
DSX
25 Páginas
-
MINODSX
6 Páginas
-
MINODSA
6 Páginas
-
DSA
15 Páginas
-
COMBIPIL
11 Páginas
-
COMBIDQJ
11 Páginas
-
MINOPAB
6 Páginas
-
BDA
11 Páginas
-
SPB
10 Páginas
-
CULTRA-Studioline
24 Páginas
-
DISA-H
34 Páginas
-
DISA-360
32 Páginas
-
DISA-300
51 Páginas
-
AQUARIS SILENT
38 Páginas
-
NBS
24 Páginas
-
CNV
29 Páginas
-
CNVA
32 Páginas
-
JK-LP/JK-LU
15 Páginas
-
HKP / HKU
16 Páginas
-
FKW
16 Páginas
-
FLARE
13 Páginas
-
RF
7 Páginas
-
KGF
9 Páginas
-
SVA-FF
8 Páginas
-
BKA-Ü
35 Páginas
-
BSK-RPR
60 Páginas
-
BKP-EN
40 Páginas
-
BAK-240
6 Páginas
-
BAK-250
14 Páginas
-
KF
4 Páginas