IG - DP CONVECTORS
1 / 2Páginas

Excertos do catálogo

IG - DP CONVECTORS - 1

INSTALLATION GUIDE - DP CONVECTORS An all-wood free-standing heater which uses the convection heating principle. Since the heater fully uses physical laws of thermodynamics it represents one of the most efficient methods of interior heating. Benefits of free-standing DP convectors: High output Silent operation Low hot water consumption Short response time Design Minimum requirements for operation and maintenance Ball valve - straight !4" 4 Screw fitting - angular W 5 Each position in the table corresponds to Figure No. 1 on aluminum fins through which the heating water flows. tion because other materials (rubber, NBR, silicon) do not provide the required sealing characteristics. 4. straight ball valve - used to shut off water supply. fig. 1: COMPONENTS OF DP CONVECTOR: 1. WOODEN CONVECTOR CASING - the all-wood casing of the convector is a design piece and encases the heat exchanger. 2. CONVECTOR GRILLE - a design piece protecting the convector outlet. It must not be covered!!! 3. HEAT EXCHANGER - copper pipes with pressed- > Select the correct convector position and location - see paragraph 4.1. 4.1 Convector Position The free-standing DP convector made by MINIB is to be floor-mounted. Place the convector so that it does not disturb the overall aesthetic experience of the room. We recommend leaving a 50-150 mm space between the convector and the wall - Figure 2. Never cover the top grille - this would result in flow reduction and a considerable decrease in the convector output (Figure 2). SCREW FITTING - a valve that controls/adjusts heating water flow. HOSE 41 mm HOSE 65 mm - the bellows hose is a stainless hose intended for fitting the connection to the convector exchanger. GASKET - seals joints between valves, hoses, and exchangers (KLINGERSIL C4400). MINIB, a.s. recommends this sealing as the optimal sealing solu- 9. SCREW ANCHOR - for anchoring the screw. 10. SCREW - for fixing the convector to the floor. 11. TEMPLATE - for marking the positions of the inlet and return pipes and for marking the convector fixing holes on the floor. Use: dry environment. } Maximum operating pressure: 1 MPa. } Maximum operating temperature: 90 °C. } Operating medium: water. The use of other media is prohibited. Water may not be mixed with other substances, such as antifreeze fluids! ) Environment: interiors with temperatures ranging between +5 °C and +40 °C. Free-standing DP convectors are designed for installation right on the floor. Please read the following instructions before you start. Plan the exact position before installation. The convector unit (all-wood body) is to be used for determination of the exact position.

Abrir o catálogo na página 1
IG - DP CONVECTORS - 2

Fix the convector using the supplied mounting accessories. The heat exchanger and the distribution pipes must be connected using the supplied stainless steel hoses. A correctly installed convector is in horizontal position and firmly supported along its entire length The stainless hoses must not be extremely stretched, stressed, or otherwise deformed. Media inlet: The ball valve (included in the standard supply) is always connected to the water inlet. Outlet (return pipe): The control valve is always connected to the outlet pipe. FIG. 6: Insert screw anchors in the prepared holes. Remove the...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos da MINIB

  1. NCA

    2 Páginas

  2. NCA 4P

    2 Páginas

  3. SKB

    2 Páginas

  4. SPB

    2 Páginas

  5. NKB

    2 Páginas

  6. NPB

    2 Páginas

  7. NEWS

    28 Páginas

  8. CONTTROLS

    3 Páginas

  9. FLOOR CONVECTORS

    72 Páginas

  10. DESIGN CONVECTORS

    12 Páginas

  11. NEWS MINIB

    3 Páginas

  12. BEST OF MINIB

    11 Páginas

  13. CATALOGUE MINIB

    108 Páginas

  14. COIL – PT300

    1 Páginas

Catálogos arquivados

  1. COIL - SW250

    1 Páginas

  2. COIL- SP2/4

    1 Páginas

  3. COIL – SP1/4

    1 Páginas

  4. COIL – NP2/4

    1 Páginas

  5. COIL – NP1/4

    1 Páginas

  6. COIL – SU2

    1 Páginas

  7. COIL – SU1

    1 Páginas

  8. COIL – NU2

    1 Páginas

  9. COIL – NU1

    1 Páginas

  10. COIL – DP

    1 Páginas

  11. COIL – LP

    1 Páginas

  12. COIL – SK2

    2 Páginas

  13. COIL – SK1

    2 Páginas

  14. COIL – NK1

    2 Páginas

  15. COIL – KP

    1 Páginas

  16. COIL – TE

    1 Páginas

  17. COIL-KT3 105

    2 Páginas

  18. COIL – KT110

    2 Páginas

  19. COIL – MT2

    2 Páginas

  20. COIL – KT3

    2 Páginas

  21. COIL – HCM4pipe

    2 Páginas

  22. COIL – HCM

    2 Páginas

  23. COIL – HC4pipe

    2 Páginas

  24. COIL – HC

    2 Páginas

  25. COIL – M0

    2 Páginas

  26. COIL – MT

    2 Páginas

  27. COIL – KT2

    2 Páginas

  28. COIL – KT1

    2 Páginas

  29. COIL – T 60

    2 Páginas

  30. COIL – KTO

    2 Páginas

  31. COIL – T80

    2 Páginas

  32. COIL-T50

    2 Páginas

  33. COIL – KT

    2 Páginas

  34. COIL – KO

    2 Páginas

  35. COIL – PW

    1 Páginas

  36. COIL – PT180

    1 Páginas

  37. COIL – PT80

    1 Páginas

  38. COIL – PO

    1 Páginas

  39. COIL – PT

    1 Páginas

  40. COIL – P

    1 Páginas

  41. COIL – SW420

    1 Páginas

  42. COIL – NW340

    1 Páginas

  43. COIL – NW170

    1 Páginas

  44. COIL – PMW205

    1 Páginas

  45. COIL – PMW165

    1 Páginas

  46. COIL – PT105

    1 Páginas

  47. COIL – PMW90

    1 Páginas

  48. COIL – PMW125

    1 Páginas

  49. MINIB 2009

    88 Páginas