FOC-EIS-180 - 1

Fire dampers for circular duct mounting. Dampers designed to maintain the fire resistance of the wall or the floor, in which a passage for ventilation, heating or air conditioning ducts has been made. They have been tested in accordance with the standards EN-1366-2 achieving the fire resistance EIS 180 (Integrity, Insulation and smoke leakage during 180 minutes), to comply with building regulations for fire safety. In case of fire, the damper stops the air passage at 72ºC by means of a fusible link that closes a blade valve. An expanding joint and another one of air tightness, as much prevent the propagation of smoke to high as to low temperature. These dampers full fill the required conditions for the (S) symbol, air-tightness to cold smoke. In case of fire, poisoning by smoke is the main cause of death. Dampers with the displaced mechanism that facilitates a good installation.

Abrir o catálogo na página 1
FOC-EIS-180 - 2

…-M7F Damper operated by an actuator with switch off device at 24 or 230v. …-MA Manual resetting damper. Is not necessary to open the box device.

Abrir o catálogo na página 2
FOC-EIS-180 - 3

Dampers made from galvanised steel and non-combustible board. ADDITIONAL ACCESSORIES /PIF/ Open / closed switches device. 200 FBC/FBA FEC/FEA CLOSED /FBC/ Electromagnet at 24/48v. Closes by electric current. /FBA/ Electromagnet at 230v. Closes by electric current. /FEC/ Electromagnet at 24/48v. Closes when current stops. /FEA/ Electromagnet at 230v. Closes when current stops. Position actuator

Abrir o catálogo na página 3
FOC-EIS-180 - 4

FIXING SYSTEMS The damper is fixed in accordance with the figure. The damper cannot be fixed in place when vibrations are occurring. 145 The dampers must be installed in a way that they can be operated manually. Precautions will have to be taken in order to ensure that the air flow reaches the fire damper uniformly. SPECIFICATION TEXT Supply and mounting of fire damper for circular duct classed EIS-180 in accordance to the European standard EN-1366-2 series FOC-EIS-180-M7F24 D=200. Operated by means of a servomotor at 24v M7F24, start and end of course switches. Dampers made from galvanised...

Abrir o catálogo na página 4
FOC-EIS-180 - 5

PRESSURE LOSS AND SOUND POWER LEVEL.

Abrir o catálogo na página 5
FOC-EIS-180 - 6

PRESSURE LOSS AND SOUND POWER LEVEL. PRESSURE LOSS AND SOUND POWER LEVEL. 300 200 150 100

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos da MADEL

  1. WAAB 4-WAY

    7 Páginas

  2. SCC

    11 Páginas

  3. LMT-S

    4 Páginas

  4. MADEL BMC

    4 Páginas

  5. MADEL AMT-AC

    6 Páginas

  6. TEO

    3 Páginas

  7. LOOK

    7 Páginas

  8. KAP

    6 Páginas

  9. TAU

    3 Páginas

  10. UFA

    4 Páginas

  11. LOF&LAIF

    6 Páginas

  12. DXL

    4 Páginas

  13. DBQ

    7 Páginas

  14. SVA-R

    6 Páginas

  15. KSP SUB

    2 Páginas

  16. KCA

    2 Páginas

  17. KBY

    3 Páginas

  18. ZMARTBOX

    4 Páginas

  19. FOC-EIS-120

    6 Páginas

  20. FTR

    3 Páginas

  21. FDS-MINI

    3 Páginas

  22. FSC-60

    3 Páginas

  23. WAAB-300

    46 Páginas

  24. WAAB-600

    46 Páginas

  25. FBK-EIS-120

    11 Páginas

  26. FOC-EIS-90

    5 Páginas

  27. FOK-EIS-180

    6 Páginas

  28. INTERFACES

    1 Páginas

  29. K1

    2 Páginas

  30. KSP

    2 Páginas

  31. KFC-PLUS

    2 Páginas

  32. KRC-PLUS

    2 Páginas

  33. SKP

    3 Páginas

  34. SKC-C

    3 Páginas

  35. SKC-R

    3 Páginas

  36. SMS

    4 Páginas

  37. SCC

    4 Páginas

  38. SQR

    7 Páginas

  39. CRG

    8 Páginas

  40. RXO

    14 Páginas

  41. AXP

    5 Páginas

  42. AXO

    30 Páginas

  43. FOK-EIS-120

    6 Páginas

  44. SVA-C

    3 Páginas

  45. DCG

    12 Páginas

  46. AX6

    10 Páginas

  47. PLAY

    11 Páginas

Catálogos arquivados

  1. madel

    9 Páginas