Excertos do catálogo

The fire dampers FBK-EIS-120 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation, which limits the risk of spreading of fire by interior of the building. These dampers can be installed in the wall *and are classified as follows: Testing European Standard EN 1366 -2 The housing is made from galvanised steel and the assembly using clinch system. It has a symmetrical design that allows wall mounting regardless of air flow. The housing is reinforced, at the height of the blade with longitudinal angles that give rigidity to the damper. The blade is made of ceramic material resistant to high temperatures and abrasion. These dampers meet the conditions required for the symbol (S) to cold smoke seal. In case of fire, smoke poisoning is the leading cause of death. Classification European Standard EN 13501-3 Classified EI 120 ( ho i ↔ o) S (E) Integrity (I) Insulation 120 minutes fire resistance (ho) Air direction: horizontal (i↔o) symmetrical (S) airtightness *(to install in the floor, see the FOK-EIS-180 series) The airtightness to the passage of cold smoke is achieved through a joint between the perimeter of the housing and the blade. For high temperatures, the damper is equipped with an expanding intumescent seal, forming a paste that prevents the passage of hot air and smoke from one side of the damper to another. The operating devices of the dampers is automatic shooting by means of a thermal fuse calibrated at 72 ° C to activate the closure when reaches that temperature. Reset is manual except for motorized dampers.
Abrir o catálogo na página 1
MADEL CLASSIFICATION FBK-EIS-120-H Damper with angled connection. Blade parallel to the large side. FBK-EIS-120-V Damper with angled connection. Blade parallel to the short side. …-M7F Damper operated by an actuator with switch off device at 24 or 230v. …-MA Manual resetting damper. Is not necessary to open the box device. 1.Housing 2. Blade 3. Airtightness seal 4. Thermal bridge 5. Transmission roads 6. Manual device 7. Driving switch 8. Thermal fuse 1.Housing 2. Blade 3. Airtightness seal 4. Thermal bridge 5. Transmission roads 6. Actuator 7. Test switch 8. Thermal fuse
Abrir o catálogo na página 2
OPERATING DEVICES …-MA Manual resetting damper. Automatic shooting by means of a thermal fuse calibrated at 72 °C. Is not necessary to open the box device to reset or to test the damper. 1. Command support 2. Command cover 3. Screw for cover attachment 4. Button to close rhe damper. 5. Terminal connection of open/closed switches device …-MA /EL/ Manual resetting damper. Automatic shooting by remote control by means of an elecromagnetement or a thermal fuse calibrated at 72 °C. Is not necessary to open the box device to reset or to test the damper. REF. ELECTROMAGNET Closes when current...
Abrir o catálogo na página 3
MOUNTING PRECAUTIONS POSITION LOCKING DEVICE PROPER INSTALLATION FBK-EIS-120-…-MA The dampers must be installed with the device on the side. IMPROPER INSTALLATION FBK-EIS-120-…-MA Manual device at the top 1 Manual device at the bottom Motorised device at the bottom The dampers have never been installed with the device at the top or at the bottom.
Abrir o catálogo na página 4
MOUNTING PRECAUTIONS WALL MOUNTING PROPER INSTALLATION IMPROPER INSTALLATION The design of the damper with driving device shaft offset from the blade, helps us the connection to the wall. To achieve the sectorization, the damper will be placed with the axis line of the blade in the work support (wall). 1. Wall 2. Locking device 3. Axis of the blade The damper will not be placed with the axis line of the blade off-site support (wall) because it would lose the function of sectorization. The locking device must be accessible and nothing impede its work. DISTRIBUTION BETWEEN DAMPER AND...
Abrir o catálogo na página 5
DAMPER RECEPTION Unpack the damper and visually check that has not been damaged during transport. Do a test at the damper (open / close) to verify that it works correctly . WALL OPENING FBK (rectangular dampers) Size of rectangular opening : (H nominal + 70 mm) x (Lnominal + 70mm) DAMPER POSITION IN THE WALL [ES] [GB] [FR] [IT] FIJACIÓN: INICIO DE MURO FIXING: WALL SITUATION FIXATION: DÉBUT DE MUR FISSAGIO: INIZIO DEL MURO [ES]FIJACIÓN: INICIO DE MURO [GB] IXING: WALL SITUATION F [FR]FIXATION: DÉBUT DE MUR [IT] FISSAGIO: INIZIO DEL MURO A.WALL (maximum thickness 120 mm) Placer le clapet à...
Abrir o catálogo na página 6
SAND AND CEMENT MORTAR • Set the damper filling with sand and cement mortar the space between the and damper and the opening. • Check that the damper blade is not trapped against the housing. • Avoid projecting mortar moving parts of damper (blade, actuator, manual device). • Once dry the damper-to-wall assembly, open and close the damper to check for proper operation. 5. CONNECTION TO AIR DUCTS •Take precautions to ensure that flow of air to get uniformly to the damper and prevent their installation in the presence of vibrations. • The inner dimension of the air ducts can not be smaller...
Abrir o catálogo na página 7
SPECIFICATION TEXT Supply and mounting of fire damper classed EIS120 in accordance to the European standard EN1366-2 series FBK-EIS-120-H-M7F230 LxH. Operated by means of a servomotor at 230v M7F230, start and end of course switches. Dampers made from galvanised steel and noncombustible board. Thermal fusible link at 72ºC. An expanding joint together an air-tightness joint, as much prevent the propagation of smoke to high as to low temperature. Manufacturer MADEL.
Abrir o catálogo na página 8
CORRECTION VALUES FOR DPt and Lwa1. FREE AREA FOR THE AIR PASS (m2),
Abrir o catálogo na página 9
FREE VELOCITY, PRESSURE DROP AND SOUND POWER LEVEL Vf (m/s)
Abrir o catálogo na página 10
Campus UAfl Fectia- ZB/rj?/i?QU Paginas (incJuids estajt 1 AVANCE QE RESUl TADQS Petickmarlo WAD EL Air Technical Di^f usion, 5.A. Avda lldefons Cerda. s/n 3.G. Box nD 5 Materia', cnsayada: Compuerta cortafuegos rectabgular con secctan narninaKde 1,000 * §GQ mm y lame de 50 mm de eapeaor. El ensayo se rgalizg gon la corrpuerta empr^adatenafci|£rB soporte vertical. Fabricante. MADEL Air Technrcal Difusibn^A Xavier Vrzcaya T£cnicD de Rasistencie al Fuega LGAI Technological Canter, S.A. Este documenta os a nivoi moramwite infcrtmaCivo. tos documentos vfllidos son Ia9 informes de ensBYO...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos da MADEL
-
WAAB 4-WAY
7 Páginas
-
SCC
11 Páginas
-
LMT-S
4 Páginas
-
MADEL BMC
4 Páginas
-
MADEL AMT-AC
6 Páginas
-
TEO
3 Páginas
-
LOOK
7 Páginas
-
KAP
6 Páginas
-
TAU
3 Páginas
-
UFA
4 Páginas
-
LOF&LAIF
6 Páginas
-
DXL
4 Páginas
-
DBQ
7 Páginas
-
SVA-R
6 Páginas
-
KSP SUB
2 Páginas
-
KCA
2 Páginas
-
KRC-PLUS-FREE-COOLING
4 Páginas
-
KBY
3 Páginas
-
ZMARTBOX
4 Páginas
-
FOC-EIS-120
6 Páginas
-
FTR
3 Páginas
-
FDS-MINI
3 Páginas
-
FSC-60
3 Páginas
-
WAAB-300
46 Páginas
-
WAAB-600
46 Páginas
-
FOC-EIS-180
6 Páginas
-
FOC-EIS-90
5 Páginas
-
FOK-EIS-180
6 Páginas
-
INTERFACES
1 Páginas
-
K1
2 Páginas
-
KSP
2 Páginas
-
KFC-PLUS
2 Páginas
-
KRC-PLUS
2 Páginas
-
SKP
3 Páginas
-
SKC-C
3 Páginas
-
SKC-R
3 Páginas
-
SMS
4 Páginas
-
SCC
4 Páginas
-
SQR
7 Páginas
-
CRG
8 Páginas
-
RXO
14 Páginas
-
AXP
5 Páginas
-
AXO
30 Páginas
-
FOK-EIS-120
6 Páginas
-
SVA-C
3 Páginas
-
DCG
12 Páginas
-
AX6
10 Páginas
-
PLAY
11 Páginas
-
ZONING SYSTEM CATALOGUE
20 Páginas
Catálogos arquivados
-
madel
9 Páginas
-
OTO Curved Vents Swirl Diffusers
7 Páginas
-
DHVC Multidirectional Diffusers
5 Páginas
-
DCN circular diffusers
8 Páginas
-
CTM Double Deflection Grilles
5 Páginas
-
AMT Single Deflection Grilles
5 Páginas