AXP
1 / 5Páginas

{{requestButtons}}

Excertos do catálogo

AXP - 1

AXP fixed blades swirl diffusers The AXP series rotational diffusers are designed to be applied in air conditioning, ventilation and heating. They are mounted in false ceilings or hanging. Their round shape together with the helical design of their blades causes a rotational diffusion of the air stream, obtaining a high induction index. With AXP diffusers it is possible to obtain good results in sound pressure in the comfort area. These diffusers can be used in premises from 2.6 to 4 meters high and a temperature differential up to 12º C.

Abrir o catálogo na página 1
AXP - 2

AXP Fixed blades circular swirl diffuser. AXP-MOD AXP diffuser specially designed to replace a 600x600 false ceiling tile. AXP-MOD/625 AXP diffuser specially designed to replace a 625x625 false ceiling tile. AXP-MOD/675 AXP diffuser specially designed to replace a 675x675 false ceiling tile. Additional accessories PLXP Plenum box with a lateral circular connection. It includes supports to hang from the ceiling. Made in galvanised steel. …-R Plenum box with a flow damper in the spigot. …/S/ Plenum box with an upper circular neck connector. …/AIS/ Plenum box thermo acoustically insulated by a...

Abrir o catálogo na página 2
AXP - 3

1) Connection into a circular metallic duct by means of rivets. P) Connection into the crossbar or to the plenum box by means of central screw. Finishes M9016 Painted in white similar to RAL 9016. R9010 Painted in white RAL 9010. P) M9006 Painted in grey similar to RAL 9006. RAL... Painted in other RAL colours. Specification text Supply and mounting of circular swirl diffuser with fixed blades series AXP+PLXP-R M9016 dim. 125 constructed from aluminium paint in white M9016. With lateral circular connection plenum box and air flow damper in the spigot PLXP-R. Manufacturer MADEL.

Abrir o catálogo na página 3
AXP - 4

RECOMMENDED VELOCITY. FREE VELOCITY, PRESSURE LOSS AND SOUND POWER LEVEL, THROW WITH CEILING EFFECT. Afree Qmin. Qmax. m2 m3/h m3/h

Abrir o catálogo na página 4
AXP - 5

MADEL CORRECTION FACTOR FOR VERTICAL DIFFUSION (bV) FOR DT (-). CORRECTON FACTOR FOR THROW (L0.2) DT (-). Kh = Correction factor for the vertical diffusion. TEMPERATURE RATIO. t room - t x t room - t supply Kl = Correction factor for the throw.

Abrir o catálogo na página 5

Todos os catálogos e folhetos técnicos da MADEL

  1. WAAB 4-WAY

    7 Páginas

  2. SCC

    11 Páginas

  3. LMT-S

    4 Páginas

  4. MADEL BMC

    4 Páginas

  5. MADEL AMT-AC

    6 Páginas

  6. TEO

    3 Páginas

  7. LOOK

    7 Páginas

  8. KAP

    6 Páginas

  9. TAU

    3 Páginas

  10. UFA

    4 Páginas

  11. LOF&LAIF

    6 Páginas

  12. DXL

    4 Páginas

  13. DBQ

    7 Páginas

  14. SVA-R

    6 Páginas

  15. KSP SUB

    2 Páginas

  16. KCA

    2 Páginas

  17. KBY

    3 Páginas

  18. ZMARTBOX

    4 Páginas

  19. FOC-EIS-120

    6 Páginas

  20. FTR

    3 Páginas

  21. FDS-MINI

    3 Páginas

  22. FSC-60

    3 Páginas

  23. WAAB-300

    46 Páginas

  24. WAAB-600

    46 Páginas

  25. FBK-EIS-120

    11 Páginas

  26. FOC-EIS-180

    6 Páginas

  27. FOC-EIS-90

    5 Páginas

  28. FOK-EIS-180

    6 Páginas

  29. INTERFACES

    1 Páginas

  30. K1

    2 Páginas

  31. KSP

    2 Páginas

  32. KFC-PLUS

    2 Páginas

  33. KRC-PLUS

    2 Páginas

  34. SKP

    3 Páginas

  35. SKC-C

    3 Páginas

  36. SKC-R

    3 Páginas

  37. SMS

    4 Páginas

  38. SCC

    4 Páginas

  39. SQR

    7 Páginas

  40. CRG

    8 Páginas

  41. RXO

    14 Páginas

  42. AXO

    30 Páginas

  43. FOK-EIS-120

    6 Páginas

  44. SVA-C

    3 Páginas

  45. DCG

    12 Páginas

  46. AX6

    10 Páginas

  47. PLAY

    11 Páginas

Catálogos arquivados

  1. madel

    9 Páginas