Excertos do catálogo

Wastewater lifting stations
Abrir o catálogo na página 1
3 Wastewater lifting stations Lifting stations for wastewater containing raw sewage Page Complete range for free-standing installation and for installation in a concrete floor Submersible pumps Lifting stations for free standing installation and for installation in a concrete floor Lifting stations for wastewater without sewage for fixed or mobile use, for residential, commercial, public and industrial applications Warning and control units Convenient monitoring and control of lifting stations and pumps Individual Solutions
Abrir o catálogo na página 2
Wastewater lifting stations – Everything the specialist needs to know Water flows upwards ? It often happens that wastewater cannot be drained with gravity because the sewer is higher than the drainage point in the basement. In this case a lifting station or pump must be used. Lifting stations pump the wastewater via pressure pipes into the sewer. Backwater level Particle size: The particle size of a pump specifies how many millimetres of free passage through the pump are available. According to the construction and testing regulations (EN 12050-2) for wastewater lifting stations for...
Abrir o catálogo na página 3
Wastewater lifting stations – Everything the specialist needs to know Installation options Example for installation in a concrete slab/floor Example for underground installation Lifting stations Example for installation in an exposed wastewater pipe Installation in a concrete floor Underground installation Free-standing lifting stations can be installed very easily and without a great deal of expenditure, and are suitable for single-family homes all the way up to larger commercial / industrial applications. Smaller systems can easily be placed in an existing basement room. Larger systems...
Abrir o catálogo na página 4
Wastewater lifting stations – Everything the specialist needs to know General information and standards Level sensors / probes and alarm probes Lifting stations Level sensors and probes measure the level of the pumping medium in the collecting tank of a lifting station and trigger the pumping process of one or several pumps from a specified filling level onward. If the level in the collecting tank continues to rise, an acoustic warning signal can be give via an alarm probe (which also measures the level of the pumping medium). Pressure sensor The closed air volume within a pressure sensor...
Abrir o catálogo na página 5
Wastewater lifting stations – Everything the specialist needs to know Selection criteria - lifting stations FOR WASTEWATER CONTAINING RAW SEWAGE AP 501 Ø 800/1000 Pressure pipe diameter Interior installation Exterior installation Input power Max. pumping height Lifting stations FOR WASTEWATER WITHOUT SEWAGE Aqualift S Ø 1000 Pressure pipe diameter Minilift Interior installation Exterior installation Input power Max. pumping height SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com
Abrir o catálogo na página 6
KESSEL-Product information Wastewater lifting stations Aqualift F Compact SmartSelect simply makes planning easier - calculation tool for lifting stations at smartselect.kessel.com Compact and powerful lifting stations Scan this QR code to directly view the corresponding product video. Single- / Twin station 40 liter tank volume Wastewater lifting stations Aqualift F Compact for installation in a concrete floor Lifting stations CHAMBER READY FOR UNDERGROUND INSTALLATION The telescopic upper section makes flexible adaptation to the required installation depth possible. Upper section can be...
Abrir o catálogo na página 7
Single station 40 liter tank volume Twin station 40 liter tank volume Lifting station for wastewater disposal in a single toilet Small lifting station Minilift F Wastewater lifting stations Aqualift F Compact for free-standing installation in frost protected rooms for free standing installation The drain contained in the cover drains all surface water. Even in the event of a pipe burst or flooding, the pump discharges water out of the house and into the sewer. Lifting stations INTEGRATED DRAIN FUNCTION MAXIMUM SAFETY THANKS TO CONTROL UNIT WITH SDS The intelligent control unit with...
Abrir o catálogo na página 8
Lifting stations for wastewater with or without sewage Aqualift F Compact Mono Installation in a concrete slab/floor Illustration and dimensioned drawing Illustration shows Lifting stations Illustration shows Products Input power Article description Lifting station Aqualift F Compact Mono / Duo for installation in a concrete slab/floor, with recessed cover for on-site tiling and drain Installation depth (D) 490 to 600 mm With odour trap, sealing water height 50 mm With lateral inlet Ø 110 With telescopic upper section for free height and level adjustment, recessed cover for on-site tiling,...
Abrir o catálogo na página 9
Lifting stations for wastewater with or without sewage Installation example Aqualift F Compact Professional advantages Plug & play Comfort control unit with self-diagnosis system SDS for maximum safety. Integrated drain function to drain surface water. Continual drainage even in the event of incoming flood water or a pipe burst. Variable upper section rotatable, tiltable and height adjustable Installation in waterproof concrete. Gasket set (Art. # 83 023) to prevent groundwater infiltration. ቢ Lifting station ባ Pressure pipe set (Art. # 28 040) ቤ Extension section ብ Gasket set ቦ Control...
Abrir o catálogo na página 10
Lifting stations Aqualift F Compact Accessories Outer diameter Ø (mm) Extension section with centre flange with elastomer sealing sheet made of NK/SBR Ø 800 mm, incl. screws for article numbers: 28 701-C, 28 704-C Extension section with flange and counter flange for connection to an on-site sealing sheet made of polymer, incl. screws max. extension 140 mm Illustration and dimensioned drawing Article description For models made on or after Jan 2011 Cover plate, surface water tight Class A 15 With drain Ø 75, includes Multistop odour, foam, rodent and insect stop incl. gasket 1 recessed for...
Abrir o catálogo na página 11
Lifting stations Aqualift F Compact When multiple extension sections are used make sure that access to valve is still possible ! Extension section made of polymer, max. extension 180 mm, incl. gasket for article numbers: 28 701-C, 28 704-C Gasket set for installation in waterproof concrete Illustration and dimensioned drawing Audible alarm 20 m cable length suitable for all control units Potential-free contact suitable for all control units 230 V: Wastewater station Aqualift F, Wastewater station Aqualift F Compact, Lifting station Aqualift F Mono 230 V Compressor set for use in combination...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos da KESSEL
-
Backwater protection
12 Páginas
-
You can never improve the original.
16 Páginas
-
Backwater Valve
8 Páginas
-
Tailor-made
24 Páginas
-
Aqualift F XXL 400 V – 60 Hz
12 Páginas
-
Pump technology
58 Páginas
-
Hybrid drainage systems
24 Páginas
-
Separators
57 Páginas
-
Drains-and-Channels
107 Páginas
-
Lifting-stations
69 Páginas
-
Hybrid-lifting-stations
19 Páginas
-
Backwater-Valves
41 Páginas
-
Catalogue3.2
326 Páginas
-
Euro Auto Mix & Pump (PV+S )
1 Páginas
-
Euro Mix & Pump (M+S )
1 Páginas
-
Euro Auto Mix (D+SP )
1 Páginas
-
Euro Mix (D+S )
1 Páginas
-
Euro Standard (D )
1 Páginas
-
Brochure avec références internationales
48 Páginas
-
Catalogue 3.1
310 Páginas
-
Drains and channels
112 Páginas
-
Hybrid lifting stations
20 Páginas
-
Backwater protection
36 Páginas
-
Brochure Ecolift
8 Páginas
-
Brochure "Staufix"
8 Páginas
-
Brochure Ecolift XL
24 Páginas
-
Product Catalogue "Leading in Drainage 2.3"
229 Páginas
-
EasyClean Grease Separators
8 Páginas
-
Aqualift F XL Lifting Stations
8 Páginas
-
Aqualift F Compact
6 Páginas
-
Separators
30 Páginas
-
Parking deck drains
18 Páginas
-
Shower channels
15 Páginas
-
Bathroom drainss
15 Páginas
Catálogos arquivados
-
Reliable backwater protection
6 Páginas