KeRmi A leading brand of AFG ■ Suitable for heated screeds of building type B acc. to DIN EN 1264 and DIN 18560 ■ Exact matching of the heat dissipation to the calculated room heating load and maintenance of the permissible floor surface temperature acc. to DIN EN 1264-2 through variation of the pipe spacing as well as calculation and regulation of the mass flow rate ■ DIN CERTCO system check, registration no. 7F 139-F/7F 140-F with determination of the heating and cooling capacity acc. to DIN EN 1264 ■ 10 years extended product liability acc. to the declaration of responsibility by Kermi System cross-section The displayed construction with 20 mm load distribution layer was laid dryly (dry screed) and serves as an example. Alternately, the use of floating screed CAF-F5 with 30 mm pipe covering is possible. Kermi x-net Technical data sheet Status 01.12.2015 Page 1 of 6 Technical specifications subject to change! We assume no liability for mistakes or printing errors. Kermi GmbH Pankofen-Bahnhof 1 94447 Plattling GERMANY
Abrir o catálogo na página 1
x-net C13 dry system Designation Image Kermi x-net drywall board 25 mm W W W W W W W W W Rigid foam insulation with pipe channels for meander-shaped pipe laying Reversing track loops and three transverse channels in the head area of the panel EPS 035 DEO acc. to DIN EN 13163 max. payload 200 kPa Building material class B1 acc. to DIN 4102, Euro class E acc. to DIN EN 13501, HBCD-free For holding x-net heat-conducting plate and x-net pipe system 14 x 2 Installation distances: 14/21 and 28 cm Thermal resistance 0.63m² K/W L x W x H = 1,000 mm x 500 mm x 25 mm Product code: SFDTBP01000 Kermi...
Abrir o catálogo na página 2
KeRmi A leading brand of AFG Quick lay-out table x-net C13 with steel heat-conducting plate, dry screed 20 mm (AScreed = 0.35 W / mK), x-net system pipe 14 x 2 Heat flow density Surface = 20°c -► 25 112 ◄- max. heating circuit length [m] 86 ◄- Mass flow [kg/h] 15 - specific cooling capacity [W/m2] ■ at an equal mass flow rate for heating and cooling The use of the Kermi quick lay-out tables does not replace a detailed calculation acc. to DIN EN 1264-3. The quick lay-out tables enable an easy and quick assessment of: ■ installation distance ■ max. heating circuit length/area per heating...
Abrir o catálogo na página 3
KeRmi A leading brand of AFG Quick lay-out table x-net C13 with steel heat-conducting plate, wet screed 30 mm (AScreed = 1.2 W / mK), x-net system pipe 14 x 2Heat flow density Surface temperature max. area per heating circuit [m2] Installation distance [cm] max. heating circuit length [m] Mass flow [kg/h] specific cooling capacity [W/m2] ■ at » = 26°C ■ at 9V = 16°C ■ at an equal mass flow rate for heating and cooling The use of the Kermi quick lay-out tables does not replace a detailed calculation acc. to DIN EN 1264-3. The quick lay-out tables enable an easy and quick assessment of: ■...
Abrir o catálogo na página 4
KeRmi A leading brand of AFG Quick lay-out table x-net C13 with aluminium heat-conducting plate, dry screed 20 mm (AScreed = 0.345 W / mK), x-net system pipe 14 x 2Heat flow density Surface temperature max. area per heating circuit [m2] Installation distance [cm] max. heating circuit length [m] Mass flow [kg/h] specific cooling capacity [W/m2] ■ at 9i = 26°C ■ at 9V = 16°C ■ at an equal mass flow rate for heating and cooling The use of the Kermi quick lay-out tables does not replace a detailed calculation acc. to DIN EN 1264-3. The quick lay-out tables enable an easy and quick assessment...
Abrir o catálogo na página 5
KeRmi A leading brand of AFG Quick lay-out table x-net C13 with aluminium heat-conducting plate, wet screed 30 mm (AScreed = 1.2 W / mK), x-net system pipe 14 x 2Heat flow density Surface temperature max. area per heating circuit [m2] Installation distance [cm] max. heating circuit length [m] Mass flow [kg/h] specific cooling capacity [W/m2] ■ at 9 = 26°C ■ at 9V = 16°C ■ at an equal mass flow rate for heating and cooling The use of the Kermi quick lay-out tables does not replace a detailed calculation acc. to DIN EN 1264-3. The quick lay-out tables enable an easy and quick assessment of: ■...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos da KERMI
-
LIGA
40 Páginas
-
IBIZA 2000
27 Páginas
-
WALK-IN XD Wall
4 Páginas
-
MENA
33 Páginas
-
Price list I/ 2021
124 Páginas
-
New products 2021
20 Páginas
-
therm-x2®
28 Páginas
-
Kermi Heating Panels / Convectors
154 Páginas
-
Kermi B20 design radiators
60 Páginas
-
Kermi design radiators
298 Páginas
-
Konvektoren
112 Páginas
-
x-net C13 dry system
16 Páginas
-
all Radiators and panel heating
44 Páginas
-
Design radiators
84 Páginas
-
x-net C16 clip system
16 Páginas
-
Company Profile
28 Páginas
-
ThermX2
24 Páginas
-
therm-x2 original
16 Páginas
-
therm-x2® steel panel radiators
140 Páginas
-
TREND SETTING DESIGN WITH FLAIR
44 Páginas
-
Shower enclosure Program
206 Páginas
-
CLASSIC CONVECTOR RADIATOR
2 Páginas
-
CONCEPT COMPACT RADIATOR
2 Páginas
-
Living Design Radiator
76 Páginas
-
Classic Convector Radiator
2 Páginas
-
Mezzo Towel Radiator 2009
4 Páginas
-
Cellax touch up paint RAL 9016
6 Páginas
-
Radiator_selection_guide_2008_UK
36 Páginas
-
Radiator_Selection_Guide
9 Páginas
-
Shower enclosures I/2011
124 Páginas
Catálogos arquivados
-
livingDesign_shower-enclosures-I_2009_2
84 Páginas