GE Premium 2
1 / 4Páginas

Excertos do catálogo

GE Premium 2 - 1

Description GE Premium 2 is a ventilation unit consisting of a counter current heat exchanger, a heat pump, supply and extract air fans, F7 supply air filter, G4 extract air filter, complete Optima 300 automatics, control panel and comfort cooling option. GE Premium 2 can be delivered with the following options: -- Water or electrical reheater for Ø200 mm duct -- Water frost sensor for water reheater -- Thermostat or motor valve for water reheater -- Electrical preheater for Ø200 mm duct -- Summer box GE Premium 2 is suitable in ventilation systems where balanced ventilation, heat recovery and warm/cool supply air is needed. At first the heat will be recovered in the counter current heat exchanger and then further heat or cooling will be supplied to the supply air by the heat pump. During the summer the heat pump can switched to a cooling mode which means that the heat pump will supply comfort cooling to the supply air. GE Premium 2 can deliver an air volume of up to appr. 375 m3/h at an external pressure of 100 Pa. Types GE Premium 2 - H (right hand) & V (left hand) Dimensions GE Premium 2 Dimension in mm. Fresh air 9. Exhaust air 10. 1. Udsugning ø200 Extract air 2. Indblæsning ø 200 11. 3. Friskluft ø 200 Supply air 12. 4. Afkast ø 200 Counter current heat exch. 13. 5. Modstrømsvarmeveksler 6. EC-Ventilator Supply air fan 14. 7. EC-Ventilator Extract air fan 15. 8. Filter Filter, extract air 9. Filter 16. 10. Kompressor Filter, supply air Compressor 11. Fordamper Evaporator 12. Kondensator Condensator 13. Højtrykspressostat 14. Procesventil High-pressure15. Kabelindføring gov. Process valve16. El-kasse 17. Kondensafløb ø20 Cable entry 18. Kondensvandsbakke 19. Inblæsnings studs bagud Switch 20. Afbryder Electrical box Condensation conn. Ø15 21. Magnetventil afrimning Condensation tub kondensator 22. Termoventil 23. Termoventil fordamper Supply boss at the back 24. Føler udsugning Ø100 25. Føler friskluft 26.valve defrosting 21. Magnetic Føler indblæsning 27. Føler for køleflade 22. Thermovalve condenser 28. Føler køleflade 29. Føler afkast 23. Thermovalve evaporater Sensor for extract air Sensor for fresh air Sensor for supply air Sensor before cooling air Sensor for cooling coil Sensor for exhaust air Four-way valve Subject to technical modifications of GE Premium 2 datasheet

Abrir o catálogo na página 1
GE Premium 2 - 2

Technical data Control panel Electrical connections (Input power supply): Without electrical heating and preheating coil 1 x 230V + N + PE + 10 A, 50 Hz With electrical heating and preheating coil Max 1.2 + 1.0 kW 1 x 230V + N + PE + 16 A, 50 Hz Fans: R3G 190 Motor: EC motor with integrated electronics Insulation class (fans): B Fan protection class: IP 44 Fan speed (Max. per motor): 3320 Rpm Fan power input (Max. per motor): 71 W Fan current (Max. per motor): 0.50 A Fan speed regulation: Individually the fans can be set to 3 different speeds The working area of the heat pump: -15°/+35°C...

Abrir o catálogo na página 2
GE Premium 2 - 3

Size: (h x l x d) ex. connecting pieces and electric box 601 x 1186 x 615 mm GE Premium 2’ capacity varies with air quantity and outdoor air temperature Cabinet: Fully closed hot galvanised plate with 30 mm Isolation. Plastic-coated white RAL 9010. Duct connection: Ø200 mm with rubber ring seal Ø100 mm with rubber ring seal Front: Front with quick locks for filter service Heat exchanger: See water resistant aluminium Condensation tub: Stainless steel Condensation connection: Stainless steel Ø15 mm Filters: Fresh air: F7 filter Exhaust air: G4 filter Weight: 126 kg Outside temperature...

Abrir o catálogo na página 3
GE Premium 2 - 4

VPC 420 EC - kapacitetskurver og SFP 1200 kurve (kapacitetskurver v. 100%, 70%, 55% og 40%) The capacity lines are based on an average of the supply and extract air volume in a unit with filters VPC 420-EC - Samlet effektforbrug (uden kompressor!) v. 100%, 70%, 55% og 40% Total power consumption For both fans and control. Heat recovery rate Temperature efficiency (%) Heat recovery rate, flow min = mout Icing of the heat exchanger at low outdoor temperatures has been left out of account. Subject to technical modifications of GE Premium 2 datasheet

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos da Genvex

  1. COMBI 185 BP

    6 Páginas

  2. ECO 400 2022

    6 Páginas

  3. ECO 375

    6 Páginas

  4. ECO 360 R

    6 Páginas

  5. ECO 275

    6 Páginas

  6. ECO 190 XL

    6 Páginas

  7. VANVEX R + / RS +

    52 Páginas

  8. GENVEX CONNECT

    2 Páginas

  9. GES Energy M

    3 Páginas

  10. GE Energy 2

    3 Páginas

  11. GE Energy 3

    3 Páginas

  12. GES Premium 1/1L

    4 Páginas

  13. GE Premium 1/1L

    4 Páginas

  14. GE Premium 3

    4 Páginas

  15. Vanvex R

    3 Páginas

  16. Vanvex RS

    3 Páginas

  17. GS-4

    3 Páginas

  18. GES Premium 1/1

    4 Páginas

  19. GE Energy 1

    3 Páginas

  20. GES Energy S

    3 Páginas

Catálogos arquivados

  1. ECO 400 2019

    20 Páginas