

Excertos do catálogo

ClimaFläkt Chillers Catalogue 2011
Abrir o catálogo na página 1
Total Energy Control Modern HVAC systems are designed to provide a comfortable and hygienic indoor environmentsothattopperformanceisgained from the use of the building and its occupants. For that you need to choose effective ventilation and cooling systems that provide you with the right Indoor Air Quality and appropriate temperature control. Fläkt Woods offers all the pieces in the puzzle from individual components through to the provision of complete air systems, now complete with a range of chillers and air based cooling equipment. Fläkt Woods’ contribution towards a sustainable...
Abrir o catálogo na página 2
Content General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 4 –5 Herm. reciprocating Compressor type Compressor type Unit type Unit type Fläkt Woods Specifications are subject to alteration without notice
Abrir o catálogo na página 3
Unit type Compressor type Water cooled chillers Product Code – Accessories Notes Fläkt Woods Specifications are subject to alteration without notice
Abrir o catálogo na página 4
General From the very beginning Fläkt Woods decided to equip its units with all devices necessary for operation. Every product is therefore designed, made and tested together with every accessory necessary for its operation. Use of external components, which are always difficult to select and size, is thus reduced to a minimum. This also means a drastic reduction in the necessary work on site for installing the unit. Fläkt Woods units give peace of mind as they offer an integrated design, industrial construction and final test and inspection complete with all components, so that they arrive...
Abrir o catálogo na página 5
General The Fläkt Woods air cooled chillers can be fitted with high effiency fans making use of electronic controll to vary the speed with minimum use of electricity. High effiency condensor fans The HYDROPack device was created to simplify to the utmost water connections of the units, while allowing freedom of choice in respect of configuration and the range of pumps to be installed. Further benefits of this system are the possibility of reducing the risk of unit failure, as it will always continue to operate even if a pump breaks down, of having a stand-by pump that may be activated...
Abrir o catálogo na página 6
KC(A,B)A Air cooled water chiller/heat pump for outdoor installation KC(A,B)A water cooling units use R-410a refrigerant. Because they are so compact, they are ideal for residential applications. And they keep on working under all conditions thanks to a variable speed fan and water pump. The KCAAand KCBAunits offer the following features: • silent operation thanks to a fan unit that operates at only 70 % of its maximum speed under normal conditions. • storage-free operation and temperature modulation for a perfect balance between output power and energy consumption. KC(A,B)A: Capacity from...
Abrir o catálogo na página 7
KC(A,B)A Air cooled water chiller for outdoor installation Technical data 17 Sizes – Cooling capacity KCAA Total input KCAA ESEER - KCAA – Heating capacity Total input COP Pump working head KCAA Number of refrigerant circuits Number and type of compressors (4) Sound pressure level KCAA Power supply Data referred to the following conditions: Internal exchanger water = 12/7 °C; external air temperature 35 °C. Total input is obtained from compressor input + fan input Air at external exchanger inlet = 6,1°C W.B.; internal exchanger water = 40/45°C ROT = rotary compressor. Sound levels refer to...
Abrir o catálogo na página 8
KC(A,B)A Air cooled water chiller/heat pump Product Code installation KCAA-aa-b-c-d-e-f 1 = With Hydronic group outdoor installation KCBA-aa-b-c-d-e-f 1 = With Hydronic group Flakt Woods Specifications are subject to alteration without notice
Abrir o catálogo na página 9
KCAC and KCBC Air cooled water chiller/heat pump for outdoor installation Product Code Air Cooled water chiller and for outdoor installation Energy recovery (a) 0 = Without (standard) 1 = With Air Cooled chiller and heat pump for outdoor installation Energy recovery (a) 0 = Without (standard) 1 = With Low temperature (c) 0 = Without (standard) 1 = With Low temperature (c) 0 = Without (standard) 1 = With Heat exchanger approvals (d) 1 = PED (European test) Heat exchanger approvals (d) 1 = PED (European test) Energy Efficicency (e) 0 = Temporate climate Fläkt Woods Energy Efficicency (e) 0 =...
Abrir o catálogo na página 10
KCAG and KCBG Air cooled water chiller/heat pump for outdoor installation KCAG and KCBG: Capacity from 24,3 to 72,2 kW Liquid chillers and heat pumps of the KCAG and KCBG series are units designed for outdoor installation and best energy efficiency in relation to their reduced size. Every unit has been conceived and made by applying state-of-the-art technology, emphasising the qualities of efficiency, self-adaption and easy installation that distinguish this product. Thanks to its constructional and electronic peculiarities, these Chillers permit: • High energy efficiency, in particular...
Abrir o catálogo na página 11
KCAG and KCBG Air cooled water chiller/heat pump for outdoor installation Technical data 82 Total input KCAG Total - KCAG Sizes – Cooling capacity KCAG ESEER - KCAG – Heating capacity Total input COP Pump working head KCAG Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply Data referred to the following conditions: Internal exchanger water = 12/7 °C; ambient temperature = 35°C Total input is obtained from the compressor input + fan input + auxiliary circuit input. Ambient temperature = 7°C (R.H. = 85%); internal exchanger water outlet temperature...
Abrir o catálogo na página 12
KCAG and KCBG Air cooled water chiller/heat pump for outdoor installation Product Code Air Cooled water chiller and for outdoor installation KC(A,B)G-a-bbb-c-d-e-f-g-h-i-j Water low temperature (a) 0 = Standard 1 = water low temperature 2 = Double set point Size (bbb) 082, 102, 122, 162, 182, 222, 262, 302 Supply voltage (c) 1 = 400, 3, 50 Hydronic group utility side (d) 0 = Hydronic group utility side: not required 1= Standard pump 2 = single-pump with reduced available head 3 = single-pump with larger available head 4 = standard double pump 5 = double pump with larger available head 6 =...
Abrir o catálogo na página 13Todos os catálogos e folhetos técnicos da FLAKT WOODS
-
SK1 TRANSFER AIR DEVICE
1 Páginas
-
KGFC EXHAUST AIR VALVE
1 Páginas
-
PWKA SQUARE SWIRL DIFFUSER
1 Páginas
-
HT ROOFMASTER® STEF EXHAUST FAN
1 Páginas
-
ERMA MEASURING DEVICE
1 Páginas
-
HT SMHA HATCH
1 Páginas
-
AP BIO Air Purification Unit
2 Páginas
-
AP BIO Air Purifier
1 Páginas
-
AP BIO
2 Páginas
-
AIR PURIFIER AP BIO
12 Páginas
-
WOODS STANDARD TEMPERATURE ROOF FANS
1 Páginas
-
ROOF UNITS HIGH TEMPERATURE (HT)
32 Páginas
-
Woods eVertical DVC Roof Fans
1 Páginas
-
UV-C
2 Páginas
-
ILOX 59Plus CREATING SPACE
4 Páginas
-
AIR HANDLING UNIT ILOX 59PLUS
12 Páginas
-
ILOX 59PLUS
2 Páginas
-
Aerofoil Axial Flow Fans
20 Páginas
-
Heat recovery unit RDAS
6 Páginas
-
THE ErP DIRECTIVE
5 Páginas
-
Product Range-Fans
11 Páginas
-
JM Multi-Stage - Cased Axial Fans
7 Páginas
-
2102 Series - Plate Axial Fans
7 Páginas
-
JM Plate - Plate Axial Fans
8 Páginas
-
JM Aerofoil - Cased Axial Fans
58 Páginas
-
Jetfoil - Tunnel Fans
16 Páginas
-
stef_stof_technical_brochure
24 Páginas
-
Catalogue Roof Fan STOF
76 Páginas
-
Shutter Roof
2 Páginas
-
Vertical Roof
2 Páginas
-
Technical Catalogue
28 Páginas
-
Centriflow Plus PM
2 Páginas
-
Centrimaster GT-1
5 Páginas
-
Air curtain
12 Páginas
-
Veloduct
66 Páginas
-
Smoke Master SMPA
12 Páginas
-
Heat recovery unit RDKG
4 Páginas
-
Plate diffuser KHLA
6 Páginas
-
Ventilation solutions
7 Páginas
-
Axial Fans
128 Páginas
-
Box Fans
8 Páginas
-
Air Curtains Range
46 Páginas
-
Exhaust air diffuser EYMA-2
6 Páginas
-
Snow screen LSJ
3 Páginas
-
Optivent Integrated Room System
5 Páginas
-
Econet Compact
8 Páginas
-
Box Section Express 2012
9 Páginas
-
iQ Star Stella
12 Páginas
-
Combi Cooler
8 Páginas
-
EXPRESS CATALOGUE 2012
47 Páginas
-
ATD Unit Heater - AEROTEMPER®
56 Páginas
-
OPTIMIX
4 Páginas