Excertos do catálogo

Single Direct Drive Plenum Fans Single direct drive plenum fans are available in Carrier’s 39M air handler sizes 03 to 61 with 3 fan wheel diameters available in most sizes. Why choose direct drive plenum fans? Direct drive plenum fans provide all of the benefits of plenum fans while eliminating the belt losses that belt driven plenum fans carry (typically 3-5%). With no belts or sheaves, routine maintenance on a direct drive plenum fan is minimal compared to its belt driven counterpart, and belt residue in the airstream is eliminated. The 39M’s large breadth of fan wheel options provides the optimal fan solution What fan wheel diameter is optimal? While this depends on the specific airflow conditions as well as the desired fan operation, having many fan wheel diameters to choose from will give you the best solution. Fans in a VAV system will spend the majority of their operation at partial load. The exact percentage of airflow where that partial load is, however, will differ from region to region and even job to job. Figure 1 shows a comparison of a typical VAV fan operation in Houston and Chicago. As can be seen, operation in Houston spends significant time above 80% of design conditions, while an operation in a climate similar to Chicago spends minimal time above 50%. Figure 1: Percentage of Design Load Operation in Houston and Chicago The best way to see the benefits of a large breadth of fan wheel offerings is with a specific example. Figure 2 (next page) shows the 3 different direct drive plenum fan wheel options for a 39M air handler size 12, selected at 6,000 cfm with a minimum expected airflow of 3,000 cfm (shown as the MP on the fan curves) and a minimum static pressure of 1.5 inches. Since VAV systems operate at partial load the majority of the time, a VAV fan should be chosen to maximize efficiency while the fan is operating at partial load. To accomplish this, the operation at partial load should be as close to the maximum static efficiency (MSE) line as possible. For those systems that will spend the majority of their time at or near 50% load (for example, Chicago) the smallest fan wheel diameter (18.2 inches) has the highest efficiency. For a climate similar to Houston, where the majority of the operation may be spent around 70-80% of design load, the 20 inch wheel provides the best efficiency. The 22.2 inch wheel provides the best efficiency for those systems expected to operate only at full load (constant volume system).
Abrir o catálogo na página 1
Figure 2: Direct Drive Plenum Fan Wheel Diameter Options Smallest wheel — best for VAV application, with highest efficiency at partial load Medium wheel — best for VAV application, with minimal fan turn down, with highest efficiency at ~75% load. Largest wheel — best for CV application, with highest efficiency at full load. Carrier’s 39M selection software can provide the ability to properly model VAV fan performance In a VAV system, the duct static pressure sensor will maintain a minimum duct static pressure to ensure adequate airflow to all zone terminals. This minimum duct static...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos da CARRIER commercial
-
Special Seismic Compliance Brochure
1 Páginas
-
40UV-UH-14SI
32 Páginas
-
42B-6SI
24 Páginas
-
A WORLD OF COMFORT PRINT
10 Páginas
-
A WORLD OF COMFORT
20 Páginas
-
AirStream™ Room Fan Coils
4 Páginas
-
2020 ActivAIR™ Induction Beams
4 Páginas
-
The CRRSA Act (ESSER I)
2 Páginas
-
A World of Comfort
2 Páginas
-
Carrier-Catalogue-2018-2019
940 Páginas
-
36CBAL,CBAJ Series Active Chilled Beams
24 Páginas
-
Axis™ Overhead Air Terminals
4 Páginas
-
AERO® Air-Handling Units
4 Páginas
-
19DV
32 Páginas
-
30XA
136 Páginas
-
30RAP
104 Páginas
-
2019 Carrier Ductless
88 Páginas
-
i-Vu® Building Automation System
5 Páginas
-
Aqua Series Air-Cooled Chillers
2 Páginas
-
Carrier VRF
44 Páginas
-
Special Seismic Compliance
1 Páginas
-
Axis Overhead Air Terminals
2 Páginas
-
New Multi Zone Variable Air Volume
2 Páginas
-
Roomtop® 50AH036-072
24 Páginas
-
OMNIZONE™ 50BV020-064
64 Páginas
-
A World of Comfort
2 Páginas
-
Low Noise Type CABINET FAN
16 Páginas
-
Performance 16 Heat Pump
4 Páginas
-
Performance™ Series Heat Pumps
4 Páginas
-
ComfortVIEW 3
6 Páginas
-
Aqua Series Water-Cooled Chillers
2 Páginas
-
i-Vu Building Automation System
8 Páginas
-
VVT Zoning System
8 Páginas
-
Heat Reclaim Chillers
2 Páginas
-
Airstream Unit Ventilators
2 Páginas
-
Airstream Room Fan Coils
2 Páginas
-
Aero Air-Handling Units
2 Páginas
-
AQUAZONE? Water Source Heat Pumps
2 Páginas
-
39HQ Airovision Air Handling Units
6 Páginas
-
17DA Centrifugal Chiller
2 Páginas
-
AXIS? Overhead Air Terminals
3 Páginas
-
Comfort? Series
2 Páginas
-
R-22 HVAC Equipment Conversion
2 Páginas
-
GEMINI? 38AKS028-044
40 Páginas
-
GEMINI? SELECT 38APS025-065, 38APD025-130
100 Páginas
-
OMNIZONE? 50BRN,BZN006-024 Water-Cooled
44 Páginas
-
ROOMTOP® 50AH024-096 Horizontal Indoor
24 Páginas
-
OMNIZONE? 50XCW06-24 Water-Cooled
44 Páginas
-
3V? Control System System Pilot
4 Páginas
-
i-Vu Open Standard & Plus
2 Páginas
Catálogos arquivados
-
2013 ActivAIR™ Induction Beams
2 Páginas
-
ROOMAIR CONDITIONERS
6 Páginas
-
AIRSTREAM™ Room Fan Coils
3 Páginas
-
Water-Cooled Chillers
3 Páginas
-
Antimicrobial Solutions
3 Páginas
-
Cooling, Heating & Power Solutions
8 Páginas