Product Data OMNIZONE™ 50XCW06-24 Water-Cooled Indoor Self-Contained Systems with PURON® Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCW single-package watercooled units with integral air-cooled condensers offer: • Compact, durable, and attractive cabinet fits any working environment • Ducted or free return with rear return connections with vertical supply air discharge • High-efficiency cooling for commercial and industrial projects • Puron® refrigerant (R-410A) Features/Benefits The Omnizone 50XCW units provide a practical and economical approach to comfort conditioning requirements for offices, factories, and other applications in existing buildings when indoor aircooled condensers are required. Design flexibility The 50XCW water-cooled indoor packaged units are designed to provide the flexibility required in replacement, renovation, and new construction. Units are available in 6 sizes from 5 tons to 20 tons which meet the needs for cooling restaurants, retail stores, warehouses, offices, and building additions. a50-8527 Copyright 2011 Carrier Corporation Form 50XCW-2PD
Abrir o catálogo na página 1
Features/Benefits (cont) The compact footprint and service from the front of the units save valuable floor space in equipment rooms. Belt drive motors provide adequate static to overcome ducting and louver static losses. These units can be installed in the equipment room or the conditioned space and used for either ducted or free return applications. Unit supply air discharge is vertical. Easy installation and maintenance The units are completely pre-piped and wired at the factory to ensure time and money saving installation and service. Exterior access panels are easily removed to provide...
Abrir o catálogo na página 2
Model number nomenclature 50XC W 24 A A – G 5 A A – 0 AA Factory-Installed Options Code See codes in unit price pages 50XC – OMNIZONE™ Indoor Packaged Unit Condenser Option W – Water-Cooled Design Revision Level 0 – Original Release Unit Size – Nominal Tons 06 – 5 14 – 12 08 – 7.5 16 – 15 12 – 10 24 – 20 Reserved for later use Condenser Coil Options A – No Low Ambient Option, No Service Valve, No Strainer Water Connections/Discharge Air Options A – Right Hand, Vertical Discharge, Ducted E – Right Hand, Horizontal Discharge, Ducted Control Options A – Standard Controls Heating Coil Options A...
Abrir o catálogo na página 3
Dimensions — 50XCW06,08 REAR RETURN, VERTICAL DISCHARGE SIZE SIZE UNIT 50XCW 06 08 WIDTH HEIGHT DEPTH COND SECTION EVAP SECTION A 53.1 53.1 B 57.0 57.0 C 29.0 29.0 D 25.8 25.8 E 31.0 31.0 NOTE: Dimensions are in inches. WATER RETURN CONN EVAPORATOR RETURN DUCT F 47.2 47.2 G 24.8 24.8 H 28.9 28.9 I 4.8 4.8 J 14.4 14.4 K 23.0 23.0 WATER SUPPLY CONN L 22.9 22.9 M 7.5 7.5 EVAP SUPPLY DUCT (Blower Opening) N 13.4 13.4 O 12.8 12.8 P 2.7 2.7 Q 19.8 7.6 SUPPLY/ RETURN DIAMETER (OD) R 1.625 1.625 a50-8667 5
Abrir o catálogo na página 5
Dimensions — 50XCW12,14 REAR RETURN, VERTICAL DISCHARGE UNIT 50XCW 12 14 WIDTH A 68.0 68.0 HEIGHT DEPTH B 64.0 64.0 C 31.2 31.2 NOTE: Dimensions are in inches. 6 COND SECTION EVAP SECTION D 28.0 28.0 E 35.5 35.5 EVAPORATOR RETURN DUCT F 61.1 61.1 G 31.8 31.8 H 29.4 29.4 I 5.5 5.5 WATER RETURN CONN J K 17.7 22.7 17.7 22.7 WATER SUPPLY CONN L M 10.8 4.2 10.8 4.2 EVAP SUPPLY DUCT (Blower Opening) N 12.5 12.5 O 13.8 13.8 P 8.5 8.5 Q 13.6 13.6 SUPPLY/ RETURN DIAMETER (OD) R 2.125 2.125 a50-8668
Abrir o catálogo na página 6
REAR RETURN, VERTICAL DISCHARGE WITH HEAD PRESSURE CONTROL (HPC) UNIT 50XCW 12 14 WIDTH A 68.0 68.0 HEIGHT DEPTH B 64.0 64.0 C 31.2 31.2 NOTE: Dimensions are in inches. COND SECTION EVAP SECTION D 28.0 28.0 E 35.5 35.5 EVAPORATOR RETURN DUCT F 61.1 61.1 G 31.8 31.8 H 29.4 29.4 I 5.5 5.5 WATER RETURN CONN J K 17.7 22.7 17.7 22.7 WATER SUPPLY CONN L M 25.6 10.1 25.6 10.1 EVAP SUPPLY DUCT (Blower Opening) N 12.5 12.5 O 13.8 13.8 P 8.5 8.5 Q 13.6 13.6 SUPPLY/ RETURN DIAMETER (OD) R 2.125 2.125 a50-8669 7
Abrir o catálogo na página 7
Dimensions — 50XCW12,14 (cont) REAR RETURN, FRONT DISCHARGE UNIT 50XCW 12 14 WIDTH A 68.0 68.0 HEIGHT DEPTH B 64.0 64.0 C 31.2 31.2 NOTE: Dimensions are in inches. 8 COND SECTION EVAP SECTION D 28.0 28.0 E 35.5 35.5 EVAPORATOR RETURN DUCT F 61.1 61.1 G 31.8 31.8 H 29.4 29.4 I 5.5 5.5 WATER RETURN CONN J K 17.7 22.7 17.7 22.7 WATER SUPPLY CONN L M 10.8 4.2 10.8 4.2 EVAP SUPPLY DUCT (Blower Opening) N 12.5 12.5 O 13.8 13.8 P 2.7 2.7 Q 13.6 13.6 a50-8670 SUPPLY/ RETURN DIAMETER (OD) R 2.125 2.125
Abrir o catálogo na página 8
REAR RETURN, FRONT DISCHARGE WITH HEAD PRESSURE CONTROL (HPC) UNIT 50XCW 12 14 WIDTH A 68.0 68.0 HEIGHT DEPTH B 64.0 64.0 C 31.2 31.2 NOTE: Dimensions are in inches. COND SECTION EVAP SECTION D 28.0 28.0 E 35.5 35.5 EVAPORATOR RETURN DUCT F 61.1 61.1 G 31.8 31.8 H 29.4 29.4 I 5.5 5.5 WATER RETURN CONN J K 17.7 22.7 17.7 22.7 WATER SUPPLY CONN L M 25.6 10.1 25.6 10.1 EVAP SUPPLY DUCT (Blower Opening) N 12.5 12.5 O 13.8 13.8 P 2.7 2.7 Q 13.6 13.6 SUPPLY/ RETURN DIAMETER (OD) R 2.125 2.125 a50-8671 9
Abrir o catálogo na página 9
Dimensions — 50XCW16,24 REAR RETURN, VERTICAL DISCHARGE UNIT 50XCW 16 24 WIDTH A 88.0 88.0 HEIGHT DEPTH B 66.7 70.8 C 31.2 31.2 NOTE: Dimensions are in inches. 10 COND SECTION EVAP SECTION D 31.2 31.2 E 35.5 39.5 WATER RETURN CONN EVAPORATOR RETURN DUCT F 81.0 81.5 G 31.8 35.8 H 33.2 33.3 I 5.5 5.5 J 17.8 17.8 K 22.8 22.8 WATER SUPPLY CONN L 10.7 10.7 M 4.2 4.2 EVAP SUPPLY DUCT (Blower Opening) N 12.5 14.9 O 13.8 13.8 P 8.5 8.6 a50-8672 Q 13.5 8.3 S 11.7 13.2 SUPPLY/ RETURN DIAMETER (OD) R 2.625 2.625
Abrir o catálogo na página 10
REAR RETURN, VERTICAL DISCHARGE WITH HEAD PRESSURE CONTROL (HPC) UNIT 50XCW 16 24 WIDTH A 88.0 88.0 HEIGHT DEPTH B 66.7 70.8 C 31.2 31.2 NOTE: Dimensions are in inches. COND SECTION EVAP SECTION D 31.2 31.2 E 35.5 39.5 WATER RETURN CONN EVAPORATOR RETURN DUCT F 81.0 81.5 G 31.8 35.8 H 33.2 33.3 I 5.5 5.5 J 17.8 17.8 K 22.8 22.8 WATER SUPPLY CONN L 25.6 25.6 M 10.1 10.1 EVAP SUPPLY DUCT (Blower Opening) N 12.5 14.9 O 13.8 13.8 P 8.5 8.6 Q 13.5 8.3 S 11.7 13.2 SUPPLY/ RETURN DIAMETER (OD) R 2.625 2.625 a50-8673 11
Abrir o catálogo na página 11
Dimensions — 50XCW16,24 (cont) REAR RETURN, FRONT DISCHARGE UNIT 50XCW 16 24 WIDTH A 88.0 88.0 HEIGHT DEPTH B 66.7 70.8 C 31.2 31.2 NOTE: Dimensions are in inches. 12 COND SECTION EVAP SECTION D 31.2 31.2 E 35.5 39.5 WATER RETURN CONN EVAPORATOR RETURN DUCT F 81.0 81.5 G 31.8 35.8 H 33.2 33.3 I 5.5 5.5 J 17.8 17.8 K 22.8 22.8 WATER SUPPLY CONN L 25.6 25.6 M 10.1 10.1 EVAP SUPPLY DUCT (Blower Opening) N 12.5 14.9 O 13.8 13.8 P 2.6 2.6 Q 13.5 8.3 S 11.7 13.2 SUPPLY/ RETURN DIAMETER (OD) R 2.625 2.625 a50-8674
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos da CARRIER commercial
-
Special Seismic Compliance Brochure
1 Páginas
-
40UV-UH-14SI
32 Páginas
-
42B-6SI
24 Páginas
-
A WORLD OF COMFORT PRINT
10 Páginas
-
A WORLD OF COMFORT
20 Páginas
-
AirStream™ Room Fan Coils
4 Páginas
-
2020 ActivAIR™ Induction Beams
4 Páginas
-
The CRRSA Act (ESSER I)
2 Páginas
-
A World of Comfort
2 Páginas
-
Carrier-Catalogue-2018-2019
940 Páginas
-
36CBAL,CBAJ Series Active Chilled Beams
24 Páginas
-
Axis™ Overhead Air Terminals
4 Páginas
-
AERO® Air-Handling Units
4 Páginas
-
19DV
32 Páginas
-
30XA
136 Páginas
-
30RAP
104 Páginas
-
2019 Carrier Ductless
88 Páginas
-
i-Vu® Building Automation System
5 Páginas
-
Aqua Series Air-Cooled Chillers
2 Páginas
-
Carrier VRF
44 Páginas
-
Special Seismic Compliance
1 Páginas
-
Axis Overhead Air Terminals
2 Páginas
-
New Multi Zone Variable Air Volume
2 Páginas
-
Roomtop® 50AH036-072
24 Páginas
-
OMNIZONE™ 50BV020-064
64 Páginas
-
A World of Comfort
2 Páginas
-
Low Noise Type CABINET FAN
16 Páginas
-
Performance 16 Heat Pump
4 Páginas
-
Performance™ Series Heat Pumps
4 Páginas
-
ComfortVIEW 3
6 Páginas
-
Aqua Series Water-Cooled Chillers
2 Páginas
-
i-Vu Building Automation System
8 Páginas
-
VVT Zoning System
8 Páginas
-
Heat Reclaim Chillers
2 Páginas
-
Airstream Unit Ventilators
2 Páginas
-
Airstream Room Fan Coils
2 Páginas
-
Aero Air-Handling Units
2 Páginas
-
AQUAZONE? Water Source Heat Pumps
2 Páginas
-
39HQ Airovision Air Handling Units
6 Páginas
-
17DA Centrifugal Chiller
2 Páginas
-
AXIS? Overhead Air Terminals
3 Páginas
-
Comfort? Series
2 Páginas
-
R-22 HVAC Equipment Conversion
2 Páginas
-
GEMINI? 38AKS028-044
40 Páginas
-
GEMINI? SELECT 38APS025-065, 38APD025-130
100 Páginas
-
OMNIZONE? 50BRN,BZN006-024 Water-Cooled
44 Páginas
-
ROOMTOP® 50AH024-096 Horizontal Indoor
24 Páginas
-
3V? Control System System Pilot
4 Páginas
-
i-Vu Open Standard & Plus
2 Páginas
Catálogos arquivados
-
2013 ActivAIR™ Induction Beams
2 Páginas
-
ROOMAIR CONDITIONERS
6 Páginas
-
AIRSTREAM™ Room Fan Coils
3 Páginas
-
Water-Cooled Chillers
3 Páginas
-
Antimicrobial Solutions
3 Páginas
-
Cooling, Heating & Power Solutions
8 Páginas