Direct Drive Fans in Carrier’s Aero® 39M Air Handlers What’s Important to You? Carrier’s 39M air handler offers a wide selection of direct drive plenum fan options. From single direct drive fans in sizes 03 through 61, dual fans in sizes 08 through 85, four fan arrays in sizes 40 through 61 and six fan arrays in the largest size air handlers sizes 50 and larger, the 39M provides the fan solution options to best fit your specific needs. What are the benefits of a fan array? The main benefit of using a fan array is the redundancy that they provide. If one fan in the array were to fail, the other fan(s) will be able to handle a portion of, if not all, the design airflow. Fan arrays typically result in shorter fan section lengths since the arrays use smaller fans and motors which ultimately determine the length of the fan section. A larger operating spectrum (especially at low flow) and high fan static efficiencies at partial load bring benefits to a fan array as well. With smaller fans and motors to potentially replace, serviceability is no doubt easier with a fan array. What are the benefits of a single fan over a fan array? The benefits of using a fan array come at a significant cost. Fan arrays, in general, are more expensive than a single fan system. Additional options such as multiple VFDs, back draft dampers and the need for maintenance access for a large fan array (for example having adequate access for a ladder inside the air handler), can add to the unit cost as well. Single fans generally have lower sound values compared to fan arrays. Sound levels are a function of the fan RPM, and smaller wheels (as seen in fan arrays) will typically have higher RPM than larger wheels that are seen in a single fan system. A fan array’s higher sound levels, however, are in the higher octave bands. While attenuation may be needed for a fan array’s sound levels, attenuation in these higher bands is relatively easy and may add only minimal cost. The serviceability of a fan array can be easier than that in a single fan system. However, by having fewer moving parts, a single fan system is less likely to experience a component failure compared to a fan array and thus is more reliable. Which solution is best for me? This depends on what’s important. Do the benefits of a fan array outweigh the drawbacks? For example, does the redundancy that the fan array provides warrant the additional first cost? Is the reduction in fan section length worth the potentially higher sound levels of a fan array? These decisions may be difficult to make seeing as how there are many trade-offs. Table 1 (next page) should be used in your decision making process, as it outlines the factors involved in choosing between a single fan or a fan array system, and which system holds the advantage.
Abrir o catálogo na página 1
Table 1: Advantages of a Single Fan and a Fan Array Parameter Installed Cost More fans increase installed cost. Back draft dampers and multiple VFDs add cost as well. Efficiency (Design Load) At or near design conditions, A single motor and fan are more efficient Efficiency (Part Load) Fan arrays will have shorter fan section lengths, however additional service clearance may be required for an array (i.e. access for a ladder). Sound levels typically increase as more fans are added. Fan arrays have higher sound, but may be easier to attenuate (higher cost and possible added airway length)....
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos da CARRIER commercial
-
Special Seismic Compliance Brochure
1 Páginas
-
40UV-UH-14SI
32 Páginas
-
42B-6SI
24 Páginas
-
A WORLD OF COMFORT PRINT
10 Páginas
-
A WORLD OF COMFORT
20 Páginas
-
AirStream™ Room Fan Coils
4 Páginas
-
2020 ActivAIR™ Induction Beams
4 Páginas
-
The CRRSA Act (ESSER I)
2 Páginas
-
A World of Comfort
2 Páginas
-
Carrier-Catalogue-2018-2019
940 Páginas
-
36CBAL,CBAJ Series Active Chilled Beams
24 Páginas
-
Axis™ Overhead Air Terminals
4 Páginas
-
AERO® Air-Handling Units
4 Páginas
-
19DV
32 Páginas
-
30XA
136 Páginas
-
30RAP
104 Páginas
-
2019 Carrier Ductless
88 Páginas
-
i-Vu® Building Automation System
5 Páginas
-
Aqua Series Air-Cooled Chillers
2 Páginas
-
Carrier VRF
44 Páginas
-
Special Seismic Compliance
1 Páginas
-
Axis Overhead Air Terminals
2 Páginas
-
New Multi Zone Variable Air Volume
2 Páginas
-
Roomtop® 50AH036-072
24 Páginas
-
OMNIZONE™ 50BV020-064
64 Páginas
-
A World of Comfort
2 Páginas
-
Low Noise Type CABINET FAN
16 Páginas
-
Performance 16 Heat Pump
4 Páginas
-
Performance™ Series Heat Pumps
4 Páginas
-
ComfortVIEW 3
6 Páginas
-
Aqua Series Water-Cooled Chillers
2 Páginas
-
i-Vu Building Automation System
8 Páginas
-
VVT Zoning System
8 Páginas
-
Heat Reclaim Chillers
2 Páginas
-
Airstream Unit Ventilators
2 Páginas
-
Airstream Room Fan Coils
2 Páginas
-
Aero Air-Handling Units
2 Páginas
-
AQUAZONE? Water Source Heat Pumps
2 Páginas
-
39HQ Airovision Air Handling Units
6 Páginas
-
17DA Centrifugal Chiller
2 Páginas
-
AXIS? Overhead Air Terminals
3 Páginas
-
Comfort? Series
2 Páginas
-
R-22 HVAC Equipment Conversion
2 Páginas
-
GEMINI? 38AKS028-044
40 Páginas
-
GEMINI? SELECT 38APS025-065, 38APD025-130
100 Páginas
-
OMNIZONE? 50BRN,BZN006-024 Water-Cooled
44 Páginas
-
ROOMTOP® 50AH024-096 Horizontal Indoor
24 Páginas
-
OMNIZONE? 50XCW06-24 Water-Cooled
44 Páginas
-
3V? Control System System Pilot
4 Páginas
-
i-Vu Open Standard & Plus
2 Páginas
Catálogos arquivados
-
2013 ActivAIR™ Induction Beams
2 Páginas
-
ROOMAIR CONDITIONERS
6 Páginas
-
AIRSTREAM™ Room Fan Coils
3 Páginas
-
Water-Cooled Chillers
3 Páginas
-
Antimicrobial Solutions
3 Páginas
-
Cooling, Heating & Power Solutions
8 Páginas