Product Data 36CBAL,CBAJ Series Active Chilled Beams 8 to 180 cfm
Abrir o catálogo na página 1
Features/Benefits Chilled beam systems are suitable for use in sensible cooling load applications where individual temperature control is required. Active chilled beam units offer: • Precise control of ventilation airflow • Sensible cooling and heating options Active chilled beam systems An active chilled beam takes a source of primary air at an inlet static pressure ranging from 0.2 to 0.8 in. wg. It distributes this air through a bank of specially designed aerodynamic nozzles and discharges the air at a high velocity into a mixing chamber. This creates a differential pressure which...
Abrir o catálogo na página 2
36CB A L C B 2 EGOY GAYYY 36CB - Chilled Beam Design Revision A - Current Design Product Style J - 1-Way Linear Slot L - 2-Way Linear Slot Unit Size - Footprint (in.) B - 48 X 24 C - 24 X 24 E - 72x24 F - 96 x 24 (36CBAL) (ETO) Nozzle Type A - 1-Row, 24-Size B - 2-Row, 24-Size C - 1-Row, 31-Size D - 2-Row, 31-Size E - 1-Row, 38-Size F - 2-Row, 38-Size G - 1-Row, 18-Size H - 2-Row, 18-Size System Type 2 - 2-Pipe, 2-Row Coil 5 - 4-Pipe, 2-Row Coil with Split Circuiting Primary Air Configuration E - End C - Center Piping Configurations B - Right Hand (2-Pipe) C - Left Hand (2-Pipe) G - Same...
Abrir o catálogo na página 3
Factory-installed options Factory-installed options Induction nozzles are available in various sizes to match capacity requirements. Coils are available in 2-pipe or 4-pipe configurations. Grilles are available in various colors with perforated return and slot supply. The grille is hinged with easy access latches. Face and trim of the grille are painted standard white color. Optional insulation on the unit exterior (inlcuding the primary air tube) is recommended when the primary air temperature supplied to the unit is below 55°F. The optional insulation used is Armacell Model AP sheet...
Abrir o catálogo na página 4
36CBAL, 2-PIPE, SIZE 02 UNIT DIMENSIONS - 0 PRIMARY AIR END CONNECTION HANGER BRACKET - LEGEND CWR — Chilled Water Return CWS — Chilled Water Supply HWR — Heated Water Return HWS — Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 5
Dimensions (cont) 36CBAL, 2-PIPE, SIZE 04 UNIT DIMENSIONS Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicate
Abrir o catálogo na página 6
36CBAL, 2-PIPE, SIZE 06 UNIT DIMENSIONS HANGER BRACKET- LEGEND CWR — Chilled Water Return CWS — Chilled Water Supply HWR — Heated Water Return HWS — Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 7
Dimensions (cont) 36CBAL, 4-PIPE, SIZE 02 UNIT DIMENSIONS PRIMARY AIR END CONNECTION Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicate
Abrir o catálogo na página 8
36CBAL, 4-PIPE, SIZE 04 UNIT DIMENSIONS -6"0 PRIMARY AIR CONNECTION 1/2" COPPER CWS HANGER BRACKET LEGEND CWR — Chilled Water Return CWS — Chilled Water Supply HWR — Heated Water Return HWS — Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 9
1/2" COPPER CWS-HANGER BRACKET- LEGEND CWR — Chilled Water Return CWS — Chilled Water Supply HWR — Heated Water Return HWS — Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 10
36CBAJ, 2-PIPE, SIZE 02 UNIT DIMENSIONS 6"0 PRIMARY AIR END CONNECTION PRESSURE TAP — Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 11
Dimensions (cont) 36CBAJ, 2-PIPE, SIZE 04 UNIT DIMENSIONS PRIMARY AIR END CONNECTION Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated
Abrir o catálogo na página 12
36CBAJ, 2-PIPE, SIZE 06 UNIT DIMENSIONS PRESSURE TAP-1 6"0 PRIMARY AIR END CONNECTION 1/2 71.75 " COPPER CWS HANGER BRACKET 1/2" COPPER HWR 6"0 PRIMARY AIR CONNECTION 1/2" COPPER CWR Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 13
Dimensions (cont) 36CBAJ, 4-PIPE, SIZE 02 UNIT DIMENSIONS PRIMARY AIR END CONNECTION Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated
Abrir o catálogo na página 14
36CBAJ, 4-PIPE, SIZE 04 UNIT DIMENSIONS Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated.
Abrir o catálogo na página 15
Dimensions (cont) 36CBAJ, 4-PIPE, SIZE 06 UNIT DIMENSIONS PRIMARY AIR END CONNECTION Chilled Water Return Chilled Water Supply Heated Water Return Heated Water Supply NOTE: Dimensions shown in inches unless otherwise indicated
Abrir o catálogo na página 16
Selection procedure Refer to Carrier Electronic Selection Program or contact your Carrier representative to determine unit size for your application. Application data Systems with chilled beams are suitable for use in sensible cooling load applications and/or where there is a requirement for individual temperature control. In offices with normal room heights, the maximum cooling capacity is 25 to 30 Btuh per sq ft of floor area. The limit is set by the maximum permissible velocity in the occupied zone, therefore high room heights can provide the opportunity for supplying a greater cooling...
Abrir o catálogo na página 17
Application data (cont) DOUBLE USE OF THE WATER COOLING TOWER MIXING VALVE 58 F WATER 57 F WATER CHILLED BEAMS WATER COOLED CHILLERS SECONDARY WATER LOOP Dehumidifier Heat Pipe 95 F Air 45 F Water T Stat 45 F Water Heat Exchanger
Abrir o catálogo na página 18
SEPARATE SYSTEMS ALTOGETHER Individual Zone Control 55 F Air T Stat Improved COP with warmer water
Abrir o catálogo na página 19
Guide specifications Active Chilled Beams HVAC Guide Specifications Size Range: 2, 4, and 6 ft Carrier Model Number: 36CBAL,J Part 1 — General 1.01 SYSTEM DESCRIPTION A. Integrated chilled beam system for ventilation, cooling, and heating. B. Chilled beam unit shall be constant volume primary airflow unit designed to induce a secondary airflow within the conditioned space using the primary conditioned air supply. Capacities and characteristics as listed in the schedule and the guide specifications that follow. 1.02 QUALITY ASSURANCE A. Unit coils shall be tested in general accordance with...
Abrir o catálogo na página 20Todos os catálogos e folhetos técnicos da CARRIER commercial
-
Special Seismic Compliance Brochure
1 Páginas
-
40UV-UH-14SI
32 Páginas
-
42B-6SI
24 Páginas
-
A WORLD OF COMFORT PRINT
10 Páginas
-
A WORLD OF COMFORT
20 Páginas
-
AirStream™ Room Fan Coils
4 Páginas
-
2020 ActivAIR™ Induction Beams
4 Páginas
-
The CRRSA Act (ESSER I)
2 Páginas
-
A World of Comfort
2 Páginas
-
Carrier-Catalogue-2018-2019
940 Páginas
-
Axis™ Overhead Air Terminals
4 Páginas
-
AERO® Air-Handling Units
4 Páginas
-
19DV
32 Páginas
-
30XA
136 Páginas
-
30RAP
104 Páginas
-
2019 Carrier Ductless
88 Páginas
-
i-Vu® Building Automation System
5 Páginas
-
Aqua Series Air-Cooled Chillers
2 Páginas
-
Carrier VRF
44 Páginas
-
Special Seismic Compliance
1 Páginas
-
Axis Overhead Air Terminals
2 Páginas
-
New Multi Zone Variable Air Volume
2 Páginas
-
Roomtop® 50AH036-072
24 Páginas
-
OMNIZONE™ 50BV020-064
64 Páginas
-
A World of Comfort
2 Páginas
-
Low Noise Type CABINET FAN
16 Páginas
-
Performance 16 Heat Pump
4 Páginas
-
Performance™ Series Heat Pumps
4 Páginas
-
ComfortVIEW 3
6 Páginas
-
Aqua Series Water-Cooled Chillers
2 Páginas
-
i-Vu Building Automation System
8 Páginas
-
VVT Zoning System
8 Páginas
-
Heat Reclaim Chillers
2 Páginas
-
Airstream Unit Ventilators
2 Páginas
-
Airstream Room Fan Coils
2 Páginas
-
Aero Air-Handling Units
2 Páginas
-
AQUAZONE? Water Source Heat Pumps
2 Páginas
-
39HQ Airovision Air Handling Units
6 Páginas
-
17DA Centrifugal Chiller
2 Páginas
-
AXIS? Overhead Air Terminals
3 Páginas
-
Comfort? Series
2 Páginas
-
R-22 HVAC Equipment Conversion
2 Páginas
-
GEMINI? 38AKS028-044
40 Páginas
-
GEMINI? SELECT 38APS025-065, 38APD025-130
100 Páginas
-
OMNIZONE? 50BRN,BZN006-024 Water-Cooled
44 Páginas
-
ROOMTOP® 50AH024-096 Horizontal Indoor
24 Páginas
-
OMNIZONE? 50XCW06-24 Water-Cooled
44 Páginas
-
3V? Control System System Pilot
4 Páginas
-
i-Vu Open Standard & Plus
2 Páginas
Catálogos arquivados
-
2013 ActivAIR™ Induction Beams
2 Páginas
-
ROOMAIR CONDITIONERS
6 Páginas
-
AIRSTREAM™ Room Fan Coils
3 Páginas
-
Water-Cooled Chillers
3 Páginas
-
Antimicrobial Solutions
3 Páginas
-
Cooling, Heating & Power Solutions
8 Páginas