Excertos do catálogo

Orchestrate improvements to wall U-values with Ancon Low Thermal Conductivity Wall Ties BUILDING PRODUCTS
Abrir o catálogo na página 1
Helping to deliver sustainable, energy-efficient buildings Wall Ties are an essential element in the strength and stability of cavity walls, but by crossing the cavity they act as a thermal bridge between the internal and external leaves. Generally speaking, the wider the insulated cavity, the more substantial the Wall Tie needs to be and the greater the effect the tie will then have on the U-value of the wall. The challenge for the Wall Tie industry, set by the Government’s ambitious energy efficiency targets, is to reduce the thermal conductivity of its products whilst continuing to meet...
Abrir o catálogo na página 2
Example Projects Zero-Carbon Retrofit, Birmingham, UK © Martine Hamilton Knight / STO Ancon TeploTie has been used in the UK’s first retrofit to achieve zero-carbon Level 6 of the Code for Sustainable Homes. The project involved the upgrade and extension of an architect’s own family home in Birmingham, which was built in the 1840s with solid brick walls. The front elevation is internally insulated to preserve the original brickwork. The rear of the property was dismantled, extended and re-built using some of the original bricks. The existing house reached the same demanding energy...
Abrir o catálogo na página 3
Futureproofing for Traditional Masonry Cavity Construction Ancon wall ties can be used in insulated cavity walls to meet the thermal performance requirements of Part L of the Building Regulations and the Code for Sustainable Homes levels 3 to 6. The range includes a BBA-approved Low Thermal Conductivity Wall Tie for cavities from 50mm to 300mm. Longer tie lengths are also available if required. Example Wall Profiles U-value Calculations using Stainless Steel Wall Ties It is important to use the actual cross-sectional area and thermal conductivity of the Wall Tie being used when calculating...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos da Ancon Building Products
-
Eazistrip
16 Páginas
-
04a_-_Ancon_Thermal_Windpost_TWP2
2 Páginas
-
Tapered Thread Couplers
12 Páginas
-
MBT MechanicallyBolted Couplers
10 Páginas
-
Staifix HRT4 Wall Tie
1 Páginas
-
2019 Staifix Wire Balloons
1 Páginas
-
Stainless steel wall ties
1 Páginas
-
CB Coupler Box and CS Coupler Strip
8 Páginas
-
EC2-Compliant Design Method
12 Páginas
-
Reinforcing Bar Couplers
28 Páginas
-
Tension and Compression Systems
16 Páginas
-
Restraint System
4 Páginas
-
Ancon Thermal Breaks
2 Páginas
-
Ancon 500 Tension Systems - ETA-060146
19 Páginas
-
Staisil HLD Acoustic Shear dowels
4 Páginas
-
Gauge Tape
2 Páginas
-
Non-Drill Wall Ties
6 Páginas
-
CCB Cellular Clay Block Wall Ties
4 Páginas
-
Refractory Fixings
8 Páginas
-
Staifix Wall Ties
2 Páginas
-
Thermally Insulated Balcony Connectors
32 Páginas
-
Special Fabrications
12 Páginas
-
Punching Shear Reinforcement
12 Páginas
-
Starter Bar Systems
8 Páginas
-
KSN Anchors
24 Páginas
-
MultiJoint & Individual Plate Dowels
12 Páginas
-
Lockable Dowels
12 Páginas
-
DSD/ESD Shear Load Connectors
20 Páginas
-
Masonry Reinforcement
16 Páginas
-
Tension and Compression Systems
16 Páginas
-
Corner Guards
2 Páginas
-
Hidden Strength
7 Páginas
-
Isolan Insulated Balcony Connectors
20 Páginas
-
Stainless Steel in Construction
12 Páginas
-
12 Page Product Guide
12 Páginas
-
Ancon Guide: CE Marking to the CPR
12 Páginas
-
Wall Ties and Restraint Fixings
32 Páginas
Catálogos arquivados
-
2016 Staifix Wire Balloons
1 Páginas
-
Channel and Bolt Fixings
20 Páginas
-
Windposts and Parapet Posts
8 Páginas