WFI
1 / 9Páginas

Excertos do catálogo

WFI - 1

Water cooled heat pump reversible water side Cooling capacity 291 ÷ 2406 kW Heating capacity 326 ÷ 2664 kW • Condenser side hot water production up to 60°C. • Production of chilled water down to -8°C. • Available also R513A refrigerant gas Electronic expansion valve Units for internal installation offering chilled/hot water, designed to mit air conditioning needs in residential/commercial complexes or industrial applications. Compact and flexible, perfect alignment to the requested load thanks to an accurate control algorithm. The base, the structure and the panels are made of galvanized steel treated with polyester paint RAL 9003. ° Standard A High efficiency FEATURES Operating field Production of chilled water up to 16°C of water produced on the evaporator side, but also suitable for use in heat pump mode with condenser water temperature up to 60°C depending on the model. With option Z (double electronic expansion valve) the unit is capable to produce chilled water temperature from -8°C up to 10°C. Mono, bi-tri circuit unit Unit with 1-2-3 refrigerant circuits designed to provide maximum efficiency at full load, ensuring high efficiency at partial loads also and ensuring continuity in case one of the circuits stops. All units are equipped with an inverter compressor combined with an on-off compressor (two-circuit sizes) or two on/off compressors (three-circuit sizes) with R134a refrigerant. The R513A (XP10) refrigerant with this type of gas is also available on the configurator. On average, the units have a yield > 2% and an EER < 3% compared to the same size with R134a. For further details refer to the technical documentation or to the Magellano selection program. The possibility to use electronic expansion valve, offers significant benefits, especially when the chiller is working with partial loads, increasing the energy efficiency of the unit. Standard for all sizes. CONTROL PCO₅ Microprocessor adjustment, with keyboard and LCD display,for easy access on the unit is a menu available in several languages. Adjustment includes complete management of the alarms and their log. Possibility to control two units in a Master-Slave configuration The presence of a programmable timer allows functioning time periods and a possible second set-point to be set. The temperature control takes place with the integral proportional logic, based on the water output temperature. AER485P1: RS-485 interface for supervision systems with MODBUS protocol. AER485P1 x n° 2: RS-485 interface for supervision systems with MODBUS protocol. AER485P1 x n° 3: RS-485 interface for supervision systems with MODBUS protocol. AERBACP: Ethernet communication Interface for protocols Bacnet/IP, Modbus TCP/IP, SNMP AERNET: The device allows the control, the management and the remote monitoring of a Chiller with a PC, smartphone or tablet using Cloud connection. AERNET works as Master while every unit connected is configured as Slave (max. 6 unit); also, with a simple click is possible to save a log file with all the connected unit datas in the personal terminal for post analysis. MULTICHILLER_EVO: Control, switch-on and switch-off system of the single chillers where multiple units are installed in parallel, always ensuring constant flow rate to the evaporators. PGD1: Allows you to control the unit at a distance. AVX: Spring anti-vibration supports.

Abrir o catálogo na página 1
WFI - 2

FACTORY FITTED ACCESSORIES ISG: Insulation kit for condensers. Mandatory accessory for machine functioning in heat pump; standard in units with desuperheater or with heat recovery. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. ACCESSORIES COMPATIBILITY Model AER485P1 AER485P1 x n° 2 (1) AER485P1 x n° 3 (1) AERBACP AERNET MULTICHILLER_EVO PGD1 (1) x Indicates the quantity of accessories to match. Antivibration Version ° A A A A A Version ° A A A A A - 2502 AVX673 Contact us. AVX674 AVX674 Contact us. 6703 Contact us. Contact...

Abrir o catálogo na página 2
WFI - 3

Description WFI Size 1101, 1251, 1401, 1601, 1801, 2101, 2401, 2502, 2801, 2802, 3201, 3202, 3602, 4202, 4802, 5602, 6402, 6703, 7203, 8403, 9603 Model Standard condensation Optimised for high condensation Version Standard (1) High efficiency Operating field Electronic thermostatic expansion valve (2) Double electronic thermostatic for low temperature (3) Set-up Standard without hood Super silenced Silenced with hood Heat recovery Without heat recovery With desuperheater (4) With total recovery (4) Evaporator Standard Evaporating unit Power supply 400V ~ 3 50Hz with fuses 400V ~ 3 50Hz with...

Abrir o catálogo na página 3
WFI - 4

WFI 2502 - 9603 - model (°) version A - gas R134a Size Model: ° Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Heating performances 40 °C / 45 °C - gas R134a (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side (1) Date 14511:2018; Water user side 12 °C / 7 °C; Water source side 30 °C / 35 °C (2) Date...

Abrir o catálogo na página 4
WFI - 5

MODEL PERFORMANCE DATA (H) - FOR TEMPERATURES WATER PRODUCED UP TO +60°C WFI 1101 - 3201 - model (H) version A - gas R134a Size Model: H Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Heating performances 40 °C / 45 °C - gas R134a (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side (1) Date 14511:2018;...

Abrir o catálogo na página 5
WFI - 6

Electric data Size Model: H Gas R134a Maximum current (FLA) Peak current (LRA) PERFORMANCE SPECIFICATIONS EVAPORATING UNITS Model performance data (°) - for condensing temperatures up to 55°C Model output data - model WFI° - AE - gas R134a Size Model: ° Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Evaporator water flow rate Pressure drop evaporator side Length of refrigerant lines from/to 0 - 10 m Gas line (C1) Gas line (C2) Gas line (C3) Liquid line (C1) Liquid line (C2) Liquid line (C3) (1) Service side water 12 °C / 7 °C;...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos da AERMEC

  1. FCZI-D

    5 Páginas

  2. FCZ-D

    5 Páginas

  3. NRG

    9 Páginas

  4. HWF

    4 Páginas

  5. WFGI

    9 Páginas

  6. WFGN

    7 Páginas

  7. WFN

    8 Páginas

  8. WRL 026 -161

    5 Páginas

  9. BHP

    6 Páginas

  10. DUALJET

    10 Páginas

  11. AERMEC FOR WINE

    20 Páginas

  12. ANK

    8 Páginas

  13. ANLI

    8 Páginas

  14. MGW

    2 Páginas

  15. NSI

    4 Páginas

  16. TA

    4 Páginas

  17. TS

    2 Páginas

  18. Omnia Radiant

    4 Páginas

  19. MHM

    4 Páginas

  20. MHW

    2 Páginas

  21. Technical Focus

    16 Páginas

  22. All product

    404 Páginas

Catálogos arquivados

  1. Data sheet - UR

    4 Páginas