Excertos do catálogo

Water cooled heat pump reversible water side Cooling capacity 291 ÷ 2406 kW Heating capacity 326 ÷ 2664 kW • Condenser side hot water production up to 60°C. • Production of chilled water down to -8°C. • Available also R513A refrigerant gas Electronic expansion valve Units for internal installation offering chilled/hot water, designed to mit air conditioning needs in residential/commercial complexes or industrial applications. Compact and flexible, perfect alignment to the requested load thanks to an accurate control algorithm. The base, the structure and the panels are made of galvanized steel treated with polyester paint RAL 9003. ° Standard A High efficiency FEATURES Operating field Production of chilled water up to 16°C of water produced on the evaporator side, but also suitable for use in heat pump mode with condenser water temperature up to 60°C depending on the model. With option Z (double electronic expansion valve) the unit is capable to produce chilled water temperature from -8°C up to 10°C. Mono, bi-tri circuit unit Unit with 1-2-3 refrigerant circuits designed to provide maximum efficiency at full load, ensuring high efficiency at partial loads also and ensuring continuity in case one of the circuits stops. All units are equipped with an inverter compressor combined with an on-off compressor (two-circuit sizes) or two on/off compressors (three-circuit sizes) with R134a refrigerant. The R513A (XP10) refrigerant with this type of gas is also available on the configurator. On average, the units have a yield > 2% and an EER < 3% compared to the same size with R134a. For further details refer to the technical documentation or to the Magellano selection program. The possibility to use electronic expansion valve, offers significant benefits, especially when the chiller is working with partial loads, increasing the energy efficiency of the unit. Standard for all sizes. CONTROL PCO₅ Microprocessor adjustment, with keyboard and LCD display,for easy access on the unit is a menu available in several languages. Adjustment includes complete management of the alarms and their log. Possibility to control two units in a Master-Slave configuration The presence of a programmable timer allows functioning time periods and a possible second set-point to be set. The temperature control takes place with the integral proportional logic, based on the water output temperature. AER485P1: RS-485 interface for supervision systems with MODBUS protocol. AER485P1 x n° 2: RS-485 interface for supervision systems with MODBUS protocol. AER485P1 x n° 3: RS-485 interface for supervision systems with MODBUS protocol. AERBACP: Ethernet communication Interface for protocols Bacnet/IP, Modbus TCP/IP, SNMP AERNET: The device allows the control, the management and the remote monitoring of a Chiller with a PC, smartphone or tablet using Cloud connection. AERNET works as Master while every unit connected is configured as Slave (max. 6 unit); also, with a simple click is possible to save a log file with all the connected unit datas in the personal terminal for post analysis. MULTICHILLER_EVO: Control, switch-on and switch-off system of the single chillers where multiple units are installed in parallel, always ensuring constant flow rate to the evaporators. PGD1: Allows you to control the unit at a distance. AVX: Spring anti-vibration supports.
Abrir o catálogo na página 1
FACTORY FITTED ACCESSORIES ISG: Insulation kit for condensers. Mandatory accessory for machine functioning in heat pump; standard in units with desuperheater or with heat recovery. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. ACCESSORIES COMPATIBILITY Model AER485P1 AER485P1 x n° 2 (1) AER485P1 x n° 3 (1) AERBACP AERNET MULTICHILLER_EVO PGD1 (1) x Indicates the quantity of accessories to match. Antivibration Version ° A A A A A Version ° A A A A A - 2502 AVX673 Contact us. AVX674 AVX674 Contact us. 6703 Contact us. Contact...
Abrir o catálogo na página 2
Description WFI Size 1101, 1251, 1401, 1601, 1801, 2101, 2401, 2502, 2801, 2802, 3201, 3202, 3602, 4202, 4802, 5602, 6402, 6703, 7203, 8403, 9603 Model Standard condensation Optimised for high condensation Version Standard (1) High efficiency Operating field Electronic thermostatic expansion valve (2) Double electronic thermostatic for low temperature (3) Set-up Standard without hood Super silenced Silenced with hood Heat recovery Without heat recovery With desuperheater (4) With total recovery (4) Evaporator Standard Evaporating unit Power supply 400V ~ 3 50Hz with fuses 400V ~ 3 50Hz with...
Abrir o catálogo na página 3
WFI 2502 - 9603 - model (°) version A - gas R134a Size Model: ° Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Heating performances 40 °C / 45 °C - gas R134a (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side (1) Date 14511:2018; Water user side 12 °C / 7 °C; Water source side 30 °C / 35 °C (2) Date...
Abrir o catálogo na página 4
MODEL PERFORMANCE DATA (H) - FOR TEMPERATURES WATER PRODUCED UP TO +60°C WFI 1101 - 3201 - model (H) version A - gas R134a Size Model: H Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Water flow rate source side Pressure drop source side Water flow rate system side Pressure drop system side Heating performances 40 °C / 45 °C - gas R134a (2) Heating capacity Input power Heating total input current COP Water flow rate system side Pressure drop system side Water flow rate source side Pressure drop source side (1) Date 14511:2018;...
Abrir o catálogo na página 5
Electric data Size Model: H Gas R134a Maximum current (FLA) Peak current (LRA) PERFORMANCE SPECIFICATIONS EVAPORATING UNITS Model performance data (°) - for condensing temperatures up to 55°C Model output data - model WFI° - AE - gas R134a Size Model: ° Cooling performance 12 °C / 7 °C - gas R134a (1) Cooling capacity Input power Cooling total input current EER Evaporator water flow rate Pressure drop evaporator side Length of refrigerant lines from/to 0 - 10 m Gas line (C1) Gas line (C2) Gas line (C3) Liquid line (C1) Liquid line (C2) Liquid line (C3) (1) Service side water 12 °C / 7 °C;...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos da AERMEC
-
FCZI-D
5 Páginas
-
FCZ-D
5 Páginas
-
NRG
9 Páginas
-
HWF
4 Páginas
-
WFGI
9 Páginas
-
WFGN
7 Páginas
-
WFN
8 Páginas
-
WRL 026 -161
5 Páginas
-
Aermec Company Profile
21 Páginas
-
BHP
6 Páginas
-
DUALJET
10 Páginas
-
AERMEC FOR WINE
20 Páginas
-
Aermec Data Centre solutions
12 Páginas
-
Aermec Guida Idronica
40 Páginas
-
Aermec Split System VRF
92 Páginas
-
ANK
8 Páginas
-
ANLI
8 Páginas
-
Aermec Company Profile
15 Páginas
-
Variable multi flow
8 Páginas
-
Split System and VRF systems 2014
44 Páginas
-
MGW
2 Páginas
-
NSI
4 Páginas
-
TA
4 Páginas
-
TS
2 Páginas
-
Omnia Radiant
4 Páginas
-
MHM
4 Páginas
-
MHW
2 Páginas
-
Technical Focus
16 Páginas
-
All product
404 Páginas
-
Split System and VRF systems
48 Páginas
-
GPUY:products guide 2012
194 Páginas
Catálogos arquivados
-
Data sheet - Fan coils
4 Páginas
-
Data sheet - Dehumidifier
2 Páginas
-
Data sheet - UR
4 Páginas
-
Data sheet - multisplit system
2 Páginas
-
Data sheet- split system
2 Páginas