TA - 1

Air handling unit with 4 row cooling coil from 4.5 up to 32 kW 5.5 a 40 kW 6 row coil heating efficiency with 4 row coil from 14.0 up to 78.0 kW 15.5 a 87.5 kW 6 row coil HORIZONTAL OR VERTICAL CONFIGURATION VERSION WITH 4-6 ROWS WATER COIL VERSION WITH 4 ROW EXPANSION COIL USING R410A VERSION WITH EXTRACTOR Features The air conditioning units in the TA range are destined to civil, commercial and hotel systems, for applications in small to medium sized environments. The units in the TA range are characterised for their compactness (indispensable requisite for typical suspended-ceiling applications), the low noise and high useful static pressure. The great availability of accessories (e.g. bag filters and the mixing chambers with 3 dampers) allows to satisfy the most varied plant requirements • Structure realised with sandwich panels with thickness of 15 mm with polyurethane (density 40 kg/m3). The intake panel is equipped with a flange for fitting to any air channels. Horizontal or vertical fixing to a wall is made sleeves are supplied for the hydraulic attacheasy by the brackets. ments and the air vent valve. Filtration of the air entrusted to class G4 filThe possibility to rotate the coils on site is ters in compliance with EN779 (thickness envisioned. 50mm) as per standard positioned at intake. • Also available are coils with 4 rows with Fans double intake centrifugal with forward direct expansion operating with R410A fluid blades and directly coupled motor. and post-heating coils with 1 and 2 rows reaThe 230V-50Hz single-phase motor has many lised in copper piping with aluminium louspeeds, of which three can be selected via the vers blocked via mechanical expansion of the control panel. pipes. Condensate drip tray interior isolated in aluminium alloy. Coils with 4, 6 rows that can be fed with hot or cooled water realised in coil in copper piping with aluminium louvers blocked via mechanical expansion of the pipes. Threaded Choosing the unit By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific implant requirements. Fields configurator: 12 | Code Code: TA Size: 09, 11, 15, 19, 24, 33, 40, 50 Configuration: H - Horizontal V - Vertical X - Extractor Example of a sale code: TA09H4 This is a TA unit, size 09 horizontal with 4 row coil. 6 | | | Version Version: 4 - Coil with 4 rows 6 - Coil with 6 rows E - R410A coil with direct expansion 4 left rows

Abrir o catálogo na página 1
TA - 2

Accessories • M2S 2 damper mixing chamber Louver pitch 50 mm; regulation pin in galva- • WMT 05 Electro-mechanical thermostat Galvanised sheet steel section complete with nised steel with diameter 8 mm mechanisaFor fan coils installed in 2 pipe systems The two air calibration dampers with galvanised tion. panel must be installed on the wall and prosheet steel louvers. tected electrically by an internal fuse. Louver pitch 50 mm; regulation pin in galva- • VRF Recovery fan section with G4 filter Has the following functions: on/off switch; nised steel with diameter 8 mm mechanisaFan unit,...

Abrir o catálogo na página 2
TA - 3

Cooling capacity with 4 row coil (2) Cooling capacity with 6 row coil (2) Cooling capacity with 4 row coil with direct exp.R-410A (3) Heating capacity with 4 row coil (4) Heating capacity with 6 row coil (4) 1 row water coil heating capacity for 4 row pipes (8) 2 row water coil heating capacity for 4 row pipes (8) Heating capacity with 4 row coil (5) Heating capacity with 6 row coili (5) 1 row water coil heating capacity for 4 row pipes (5) 2 row water coil heating capacity for 4 row pipes (5) Electric coil capacity Number of electric coil stages Electric coil power supply Fans Motors Fans...

Abrir o catálogo na página 3
TA - 4

TA HORIZONTAL INSTALLATION AND WITH EXTRACTOR HORIZONTAL CONFIGURATION DIMENSIONS AND "EXTRACTOR" CONFIGURATION_ VERTICAL CONFIGURATION DIMENSIONS Fixing points The technical data given on this documentation is not binding. Aermec S.p.A. reserves the right to apply at any time all the modifications deemed necessary for improving the product.

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos da AERMEC

  1. FCZI-D

    5 Páginas

  2. FCZ-D

    5 Páginas

  3. NRG

    9 Páginas

  4. HWF

    4 Páginas

  5. WFGI

    9 Páginas

  6. WFGN

    7 Páginas

  7. WFI

    9 Páginas

  8. WFN

    8 Páginas

  9. WRL 026 -161

    5 Páginas

  10. BHP

    6 Páginas

  11. DUALJET

    10 Páginas

  12. AERMEC FOR WINE

    20 Páginas

  13. ANK

    8 Páginas

  14. ANLI

    8 Páginas

  15. MGW

    2 Páginas

  16. NSI

    4 Páginas

  17. TS

    2 Páginas

  18. Omnia Radiant

    4 Páginas

  19. MHM

    4 Páginas

  20. MHW

    2 Páginas

  21. Technical Focus

    16 Páginas

  22. All product

    404 Páginas

Catálogos arquivados

  1. Data sheet - UR

    4 Páginas