MHM - 1

Multisplit system heat pumps MultiSplit System with powers from 4.1 up to 11.6 kW with Inverter Remote control Trialsplit Remote control Quadrisplit MHM_C Wired control panel = MHM_W MHM_C MHM_CS MHM_D MHM_F MHM_FS Remote control Features Dualsplit: • MHM42, MHM52 and MHM72 outdoor units that can be coupled to 1 or 2 indoor unit Trialsplit: • MHM73 outdoor unit can be coupled to 2 or 3 indoor units Quadrisplit: • MHM84 and MHM104 outdoor unit can be coupled to 2, 3 or 4 indoor units Pentasplit: • MHM125 outdoor unit can be coupled to 3, 4 or 5 indoor units Indoor units selected from: • Wall (Wall installation) with remote control: MHM 20W - 25W - 35W - 50W • Cassette 600x600 (Suspended ceiling installation) with remote control and wired control panel: MHM 35CS - 50CS (coupling with the MHMGL40S accessory is mandatory) • Cassette 840x840 (Suspended ceiling installation) with remote control and wired control panel: MHM 35C - 50C - 70C (coupling with the MHMGL40 accessory is mandatory) • Floor Ceiling (Wall and/or ceiling installation) with remote control and wired control panel: MHM 25F - 35F - 50F - 70F • Ducted (Orizontal installation only) with remote control and wired control panel: MHM 25D - 35D - 50D - 60D - 70D • Console (Vertical installation only) with remote control: MHM 25FS - 35FS - 50FS • R410A refrigerant gas • Inverter device for large energy saving and optimisation of environment conditions • Indoor unit with 3 speed fan • Multi-speed single-fan external units • Variable speed rotary compressor • Air flow louvered fins with horizontal adjustment facility (MHM_W, MHM_C, MHM_CS, MHM_F, MHM_FS) • Air flow louvered fins with horizontal adjustment facility Motorized louver for vertical adjustment of outlet air flow direction (MHM_W, MHM_C, MHM_ CS, MHM_F, MHM_FS) • Silent functioning • Infrared ray remote control with liquid crystal display wired control panel for checking all functions • Wired control panel with liquid crystal display for checking all functions (MHM_C, MHM_CS, MHM_D, MHM_F) • Microprocessor control • Possibility to set the room temperature probe in intake of the indoor unit or in the wired control panel (MHM_C, MHM_CS, MHM_D, MHM_F) • Timer for programming switch-off or switchon • Cooling, heating, dehumidifying, fan only automatic functioning programs (heating/cooling) • Self-diagnostics function • Air filter with easy extraction and cleaning • Efficient defrosting contro • Standard supply condensate drain pump in the MHM_C, MHM_D versions • Refrigerant lines with flared connections • Systems with multi-line refrigerant connections, where every indoor unit is connected to the outdoor unit via dedicated refrigerant lines • Total length of the refrigerant lines: up to 20m for the outdoor units MHM42, MHM52 e MHM72 up to 70m for the outdoor units MHM73, MHM84 e MHM104 up to 80m for the outdoor units MHM125

Abrir o catálogo na página 1
MHM - 2

Air flow and recovery grid. The flow louvers are powered. Equipped with infrared receiver datory accessory as the MHM_C and MHM_ CS units are delivered without. Allowed combinations of indoor units Dualsplit: the installation of 1 or 2 indoor units is possible Dualsplit MHM 42 (14k) outdoor unit Total (k) Unit A Unit B Dualsplit MHM 52 (18k) outdoor unit Total (k) Unit A Unit B Dualsplit MHM 72 (24k) outdoor unit Total (k) Unit A Unit B _Trialsplit: it is mandatory to install at least 2 indoor units for correct system functioning_ _Trialsplit MHM 73 (24k) outdoor unit_ Total (k)_Unit A_Unit...

Abrir o catálogo na página 2
MHM - 3

Technical data Outdoor units MHM (nominal) W (min-max) W (nominal) W (min-max) W/W Cooling capacity Total input power EER *** Energy efficient class (nominal) (min-max) (nominal) (min-max) Heating capacity Input power COP *** Energy efficient class Compressor Sound Pressure Max number of units that can be connected Power Supply Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid...

Abrir o catálogo na página 3
MHM - 4

* coupling with the MHMGL40S accessory is mandatory (mm 650x650) **coupling with the MHMGL40 accessory is mandatory (mm 950x950) The technical data given on this documentation is not binding. Aermec S.p.A. reserves the right to apply at any time all the modifications deemed necessary for improving the product. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos da AERMEC

  1. FCZI-D

    5 Páginas

  2. FCZ-D

    5 Páginas

  3. NRG

    9 Páginas

  4. HWF

    4 Páginas

  5. WFGI

    9 Páginas

  6. WFGN

    7 Páginas

  7. WFI

    9 Páginas

  8. WFN

    8 Páginas

  9. WRL 026 -161

    5 Páginas

  10. BHP

    6 Páginas

  11. DUALJET

    10 Páginas

  12. AERMEC FOR WINE

    20 Páginas

  13. ANK

    8 Páginas

  14. ANLI

    8 Páginas

  15. MGW

    2 Páginas

  16. NSI

    4 Páginas

  17. TA

    4 Páginas

  18. TS

    2 Páginas

  19. Omnia Radiant

    4 Páginas

  20. MHW

    2 Páginas

  21. Technical Focus

    16 Páginas

  22. All product

    404 Páginas

Catálogos arquivados

  1. Data sheet - UR

    4 Páginas