

Excertos do catálogo

FAN COILS Fan coil for vertical wall-mounting or free-standing installation Cooling capacity 0,89 ÷ 4,25 kW Heating capacity 2,02 ÷ 8,50 kW • Total comfort in every season • Electric saving equal to 50% with respect to a fan coil with 3-speed motor • Fully silent operation • Backlit Touch command with programming via a smart device (DT vesion) Protective metal cabinet with anti-corrosion polyester RAL 9003 paint, whereas the head with the air distribution grille is in RAL 7047 plastic. Ventilation group Centrifugal fans in anti-static plastic material with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise. Their characteristics permit energy savings compared to conventional fans. They are statically and dynamically balanced and directly coupled to the motor shaft. The Brushless electric motor with 0-100% continuous speed variation, which allows precise adaptation to the real demands of the internal environment without temperature fluctuations. Air filter class Coarse 25% for all versions easy to pull out and clean. VERSION WITH DOUBLE SUPPLY FCZI_D — With on-board thermostat. FCZI_DT — With thermostat T-TOUCH-I on-board the system — Compatibility with VMF system. FCZI_DS — Without installed switch — Compatibility with VMF system. The perception of uneven temperature distribution in various settings, especially in the vertical direction, is one of the main factors leading to a drastic reduction in the well-being perceived by occupants. FCZI D are able to provide a pleasant sensation of comfort by directing the air in a way that ensures uniform temperature distribution throughout the setting. In winter, hot air is direct downwards; in summer, cool air is directed upwards. Air supply switching at the front or from the top by operating directly on the orientable grille. They can be installed in any type of 2 / 4 pipe system and in combination with any heat generator even at low temperatures. Thanks to the availability of several versions and configurations, it is easy to choose the optimal solution for every requirement. Finned pack heat exchanger With copper pipes and aluminium louvers, the main heat exchanger has female gas water connections on the left side and the manifolds have air vents. The coil is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The hydraulic connections can be inverted during installatio
Abrir o catálogo na página 1
Control panels AER503IR: Flush-mounting thermostat with backlit display, capacitive keypad and infrared receiver, for controlling both brushless fan coils and those with an asynchronous motor. In 2-pipe systems, the thermostat can control standard fan coils or those equipped with an electric heater, with air purifying devices (Cold Plasma and germicidal lamp), with radiant plate or with FCZ-D twin delivery (Dualjet). In addition, it can control systems with radiant panels or mixed (fan coil and radiant floor) systems. Being equipped with an infrared receiver, it can, in turn, be controlled...
Abrir o catálogo na página 2
Control panels (1) Wall-mount installation. (2) Probe for AER503IR-TX thermostats, if fitted. (3) Wall-mounting. If the unit intake exceeds 0.7A, or several units need to be managed with a single thermostat, board SIT3 and/or SIT5 is required. For more information about VMF system, refer to the dedicated documentation. Model Ver 200 DI24 DS • VMF-E19I (1) DS • VMF-E2Z DS • VMF-E3 DS,DT • VMF-E4DX DS,DT • VMF-E4X DS,DT • VMF-IO DS • VMF-IR DS • VMF-SW DS • VMHI DS • Ver D,DS,DT D,DS,DT D,DS,DT D,DS,DT Ver D,DS,DT D,DS,DT D,DS,DT D,DS,DT Water valves Valve Kit for 4 pipe systems Model Ver...
Abrir o catálogo na página 3
FAN COILS Condensate drip Model BCZ4 (1) Panel closing the rear of the unit Model Ver PCZ200 D,DS,DT PCZ300 D,DS,DT PCZ500 D,DS,DT Ver D,DS,DT D,DS,DT D,DS,DT Pair of stylish structural feet Model Ver ZXZ D,DS,DT Supports to be combined with the ornamental grille (GA) for floor installation of the fan coil Model Ver 200 300 FIKIT200 D,DS,DT • FIKIT300 D,DS,DT • FIKIT500 D,DS,DT 300 • Centrifugal Inverter Heating performance 70 °C / 60 °C (1) Heating capacity Water flow rate system side Pressure drop system side Heating performance 45 °C / 40 °C (2) Heating capacity Water flow rate system...
Abrir o catálogo na página 4
Dimensions and weights A B C Empty weight Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293577 www.aermec.com Aermec reserves the right to make any modifications deemed necessary. All data is subject to change without notice. Aermec does not assume responsibility or liability for errors or omissions. FCZI-D_Y_UN50_
Abrir o catálogo na página 5Todos os catálogos e folhetos técnicos da AERMEC
-
FCZ-D
5 Páginas
-
NRG
9 Páginas
-
HWF
4 Páginas
-
WFGI
9 Páginas
-
WFGN
7 Páginas
-
WFI
9 Páginas
-
WFN
8 Páginas
-
WRL 026 -161
5 Páginas
-
Aermec Company Profile
21 Páginas
-
BHP
6 Páginas
-
DUALJET
10 Páginas
-
AERMEC FOR WINE
20 Páginas
-
Aermec Data Centre solutions
12 Páginas
-
Aermec Guida Idronica
40 Páginas
-
Aermec Split System VRF
92 Páginas
-
ANK
8 Páginas
-
ANLI
8 Páginas
-
Aermec Company Profile
15 Páginas
-
Variable multi flow
8 Páginas
-
Split System and VRF systems 2014
44 Páginas
-
MGW
2 Páginas
-
NSI
4 Páginas
-
TA
4 Páginas
-
TS
2 Páginas
-
Omnia Radiant
4 Páginas
-
MHM
4 Páginas
-
MHW
2 Páginas
-
Technical Focus
16 Páginas
-
All product
404 Páginas
-
Split System and VRF systems
48 Páginas
-
GPUY:products guide 2012
194 Páginas
Catálogos arquivados
-
Data sheet - Fan coils
4 Páginas
-
Data sheet - Dehumidifier
2 Páginas
-
Data sheet - UR
4 Páginas
-
Data sheet - multisplit system
2 Páginas
-
Data sheet- split system
2 Páginas