OPTIPAC - 1

All Seasons Optipac Heat Pump The ■ The most powerful heat pump in the range ■ SCROLL Copeland compressor ■ Refrigerating fluid R 407 C ■ All Seasons: “intensive” defrosting by cycle inversion (operation from - 8°C) ■ Heating priority function Optipac 15 D tri **** W20TI30D W20TI30V Optipac 15 D tri **** Technical specifications Optipac 30 tri *** (Standard) W20TI15D Standard model Optipac 30 D tri **** Optipac 30 D tri **** (1) Optipac 30 tri **** Performance conditions 1: Air 15° C / Water 24° C / Humidity 70% (Nominal Zodiac) Consumed power (kW) 14 28 28 Operating power at 15° C (kW) 45 90 90 COP 3,2 3,2 3,2 Performance conditions 2: Air 28° C / Water 28° C / Humidity 80% Operating power at 15° C (kW) 54 108 108 COP 3.53 3,53 3,53 Performance conditions 3:Other power (“cold” conditions) Operating power at 7° C (kW) 36 72 - Operating power at -3° C (kW) 24,5 49 - Average water flow (m3/hr) 15 30 30 Max pool volume** contact us Load loss (mCE) 1,5 1,5 1,5 Hydraulic connection PVC Ø 63 PVC Ø 90 PVC Ø 90 Power supply 400 V / 50 Hz 400 V / 50 Hz 400 V / 50 Hz 52,2 Absorbed intensity (A) 26,1 52,2 Power cable cross section (mm2)** 4x6 4 x 16 4 x 16 Acoustic power (dBA)*** 82 85 85 Acoustic pressure at 10 m. (dBA)*** 54 57 57 Weight (kg) 350 700 700 * Outside air temperature 15°C. ** Please send us the questionnaire for a computerised assessment (page 13). *** For a maximum length of 25 metres. (1) new model available from 1st quarter 2010. Check availability with your sales contact. For all orders of Optipac 15 D or 30 D a deposit of 30% will be requested. ACCESSORIES Remote control module Cleaning Kit PAC Net WCE03469 WMA03491 Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

Open the catalog to page 1
OPTIPAC - 2

Optipac All Seasons INSTALLATION no obstacles above • utdoors, close to the technical facility. O water treatment pump filter • ydraulic connection PVC Ø 63 by filter by-pass H (PVC Ø 90 on OPTIPAC 30 D). • Plan a gap of 50 cm between the back of the heat pump and the wall. • lectric power supply protected by a 30 mA ground E fault circuit breaker (not supplied). • n annual control of the water tightness of the A refrigerating circuit must be carried out for all refrigerating equipment with a refrigerating fluid load of > than 2 kg and < than 30 kg (see art 3 of the 7/05/07 decree, French...

Open the catalog to page 2

All ZODIAC - POOLCARE catalogs and technical brochures

  1. AquaLink TRi

    2 Pages

  2. CAE

    4 Pages

  3. DT 850

    1 Pages

  4. Omega

    4 Pages

  5. Ei

    2 Pages

  6. pH Perfect

    2 Pages

  7. NATURE SPA

    2 Pages

  8. TRI

    2 Pages

  9. POWERFALL

    3 Pages

  10. Heat Line

    2 Pages

  11. RE/I

    2 Pages

  12. RE/L

    2 Pages

  13. RE/U

    2 Pages

  14. RED LINE

    2 Pages

  15. URANUS

    2 Pages