Overview: The document provides technical specifications and options for the CAE series, which includes models CAE 508, CAE 510, and CAE 513. These units are designed for dehumidification and air heating, suitable for installation in technical rooms adjacent to pool halls.
Specifications:
  • Models: Available in single-phase and three-phase configurations, with dehumidification capacities ranging from 8 to 13.5 liters per hour.
  • Power: Absorbed power varies from 2710W to 5430W, with operating power from 6500W to 13030W.
  • Air Flow: Nominal air flow ranges from 2040 to 3400 m3/hr, with available pressure between 15 and 23 mm CE.
  • Electric Supply: Single-phase models operate at 230V, while three-phase models require 400V.
  • Refrigerant: Uses R407C refrigerating fluid.
  • Acoustic Power: Measured at 77.6 dB(A).
Options:
  • Heating Options: Models can be equipped with electric heaters or hot water batteries, with or without condensers.
  • Suction and Blower Options: Standard and optional configurations for air suction and blower placement are available, including rear, front, and side options.
  • Accessories: Includes sound traps, extraction boxes, and blower angles for customized installation.
Installation Recommendations:
  • Units should be installed in a technical room close to the pool hall, with a complete duct network for optimal air extraction and distribution.
  • Hot, dry air blowers should be installed around the pool with linear blowers fitted with adjustment registers in front of window bays.
Compliance and Maintenance:
  • Units comply with EN ISO 3741 and EN ISO 354 standards.
  • A yearly check of the refrigerating circuit is required for equipment with refrigerant loads between 2kg and 30kg.
See more

Catalog excerpts

CAE-1

CAE Vertical ducted unit The ■ Easy installation, in the technical room ■ Available in 3 capacities (8 to 13.5 l/hr) ■ « Air heating » option (electric heating or hot water battery) ■ « Water heating » option (water condenser) ■ New HYGRO CONTROL box CAE 508 single phase Standard model Model with water condenser option Model with air heating option using electric heaters Model with air heating option using electric heaters and condenser Model with air heating option using ho water battery Model with air heating option using hot water battery and condenser Technical specifications Electric power supply Nominal intensity (Amps) Max. absorbed intensity (Amps) Refrigerating fluid For all orders of a DF a deposit of 30% will be requested on order. * Under the following nominal conditions: air 30° C, humidity 70%. ** Values measured and certified compliant with the EN ISO 3741 and EN ISO 354 standards by the CTTM (Centre de Transfert de Technologie du Mans). *** A yearly check of the sealing of the refrigerating circuit must be made for all refrigerating equipment of which the load in refrigerating fluid is >than 2kg and < than 30 kg (see 3 of the 7/05/07 order, French decree n° 737-2007). Battery specifications Power (kW) with primary at 90/70°C Power (kW) with primary at 45/40°C Non-contractual document subject to modification - Contact your retailer should you require further information - www.zodiac-poolcare.com

 Open the catalog to page 1
CAE-2

CAE Suction AND BLOWER OPTIONS • amp air suction: the standard suction is D made in the lower back part of the CAE. Optionally, the extraction can be made in the lower part on the left or right side of the CAE. • ry air blower: the standard blower D is on the high part of the top of the CAE. Optionally the blower can be installed in the top part on the front or the back of the CAE. Hygro Control box (supplied with the appliance, depending on availability date) Extractor on the left (frame + filter) 1 Extractor on the right (frame + filter) Rear blower (frame) Front blower (frame) 1 Rear inlet...

 Open the catalog to page 2
CAE-3

CAE SUCTION AND BLOWER CASING Circular rear extraction accessories (2) Circular side extraction accessories (2) Circular top extraction accessories (3) Circular front/rear extraction accessories (2) (2) Plan either left or right option (3) Plan front or rear blower. Other accessories: contact us Inlet ducts: circular rear Inlet ducts: circular side Inlet ducts: circular side ANGLED OUTLET - EXTRACTOR BOX Blower ducts: circular top Blower ducts: circular rear Blower ducts: circular front Circular angled outlet metal accessories: contact us Angled outlet outlet SOUND TRAP ■ Circular sound trap...

 Open the catalog to page 3
CAE-4

CAE ACCESSORIES FOR CAE WITH MINI DUCT NETWORK • et of grates and metal accessories for installing the CAE in a technical room adjacent to the S pool hall: 2 625x425 grates including one with air deflection, sound trap, blower angle. CAE 508 625x425 grate (plan for 2 grates) Double 625x425 deflector (blower) Sound trap Blower angle INSTALLATION • pper range technical solution making it possible U to obtain an excellent result anywhere in the building and especially on window bays. • nstallation in a technical room close to the pool hall. I • lan a complete duct network for extraction P of the...

 Open the catalog to page 4

All ZODIAC - POOLCARE catalogs and technical brochures

  1. AquaLink TRi

    2  Pages

  2. DT 850

    1  Page

  3. Omega

    4  Pages

  4. Chlor Perfect

    2  Pages

  5. Ei

    2  Pages

  6. pH Perfect

    2  Pages

  7. NATURE SPA

    2  Pages

  8. TRI

    2  Pages

  9. POWERFALL

    3  Pages

  10. Heat Line

    2  Pages

  11. OPTIPAC

    2  Pages

  12. RE/I

    2  Pages

  13. RE/L

    2  Pages

  14. RE/U

    2  Pages

  15. RED LINE

    2  Pages

  16. URANUS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.