Tecla 55 X1/X2/X4/X6
2Pages

{{requestButtons}}

Catalog excerpts

Tecla 55 X1/X2/X4/X6 - 1

Tecla 55 X1/X2/X4/X6 Polycarbonate Capacitive push button of 55x55 with 1/2/4/6 buttons and customizable icons ZVIT55X1 / ZVIT55X2 / ZVIT55X4 / ZVIT55X6 1 input for temperature probe Touch confirmation through acoustic feedback Proximity and luminosity sensor Total data saving on KNX bus failure Flush mount on back box Customizable polycarbonate surface with 1/2/4/6 touch areas with backlight Conformity with the CE directives (CE-mark on the back side) 1. Decorative frame (sold separately) 6. Fixing clips Figure 1: Tecla 55 X1/X2/X4/X6 2. Metallic levelling plate 3. KNX connector 4. Programming LED 5. Programming button (1 and 1.5mm) 7. Temperature probe 9. Luminosity and 10. Temperature probe ref. 8. Touch area connector proximity sensor 9900015 (included) Programming button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe mode. Programming LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash. GENERAL SPECIFICATIONS CONCEPT Type of device DESCRIPTION Electric operation control device 29VDC SELV 21..31VDC mA mW ZVIT55X6 (9.3) ZVIT55X6 (269.7) ZVIT55X4 (7.8) ZVIT55X4 (226.2) ZVIT55X2 (6.1) ZVIT55X2 (176.9) ZVIT55X1 (5.9) ZVIT55X1 (171.1) ZVIT55X6 (12.5) ZVIT55X6 (300) ZVIT55X4 (10) ZVIT55X4 (240) ZVIT55X2 (10) ZVIT55X2 (240) ZVIT55X1 (10) ZVIT55X1 (240) Typical TP1 bus connector for 0.80mm Ø rigid cable Not required 0°C .. +55°C -20°C .. +55°C 5 .. 95% 5 .. 95% Class B III Continuous operation Type 1 Long IP20, clean environment Flush mount on back box Not required Data saving according to parameterization Data recovery according to parameterization The programming LED indicates programming mode (red). Backlighting of touch areas depending on their parameterization. 38g 175V PC+ABS FR V0 halogen free Voltage (typical) Voltage range Voltage 29VDC (typical) KNX supply Connection type External power supply Operation temperature Storage temperature Operation humidity Storage humidity Complementary characteristics Protection class Operation type Device action type Electrical stress period Degree of protection Installation Minimum clearances Response on KNX bus failure Response on KNX bus restart Operation indicator Weight PCB CTI index Housing material ¹ Maximum consumption in the worst-case scenario (KNX Fan-In model). © Zennio Avance y Tecnología S.L. Further informatio

Open the catalog to page 1
Tecla 55 X1/X2/X4/X6 - 2

TEMPERATURE PROBE INPUT SPECIFICATIONS AND CONNECTIONS CONCEPT Number of inputs Operation voltage Operation current Switching type Connection method Cable cross-section NTC probe length NTC accuracy (@ 25°C) ² Temperature resolution Maximum response time DESCRIPTION 1 +3.3VDC in the common 1mA @ 3.3VDC Dry voltage contacts between input and common Pluggable screw terminal block 0.2-1mm² (IEC) / 26-16AWG (UL) 1m ±0.5°C 0.1°C 10ms ² For Zennio temperature probes. FRAME TEMPERATURE SENSOR SPECIFICATIONS CONCEPT DESCRIPTION Measuring range -30 .. +90°C Temperature resolution 0.1°C NTC accuracy...

Open the catalog to page 2

All ZENNIO AVANCE Y TECNOLOGIA catalogs and technical brochures

  1. Zennio

    63 Pages

  2. ALLinBOX 88

    4 Pages

  3. ALLinBOX 46

    4 Pages