Open the catalog to page 1Advantages ■ Energy saving due to use of renewable energy from the ground ■ Maximum comfort due to pre-heating of outdoor air in winter using geothermal energy and temperature control of outdoor air in summer and winter for a comfortable indoor climate. ■ Compact, quick installation directly adjacent to the ventilation unit ■ Simple and sustainable use of geothermal energy with a low power consumption ■ Brine pump with energy efficiency class A ■ Air exchange in spite of low outdoor temperatures The Zehnder ComfoFond-L Q brine-earth heat exchanger has been developed for use in conjunction with...
Open the catalog to page 2Tender specification Zehnder ComfoFond-L Q brine-earth heat exchanger suitable for ComfoAir Q350/450/600 comfort ventilation units. In winter, the ComfoFond-L Q preheats the outdoor air before it enters the ventilation unit; in summer, it cools and dehumidifies the outdoor air. It is used as an extension option to the ComfoAir Q comfort ventilation unit, and can be installed compactly directly adjacent to the comfort ventilation unit. All necessary hydraulic components are included in the scope of delivery, such as the circulation pump, expansion tank, filling and flushing system, manometer and...
Open the catalog to page 3COMFOFOND-L Q 3.2.1 Maßskizze ComfoFond-L Q TR L mit ComfoPipe Plus 3.2.1 Dimensional drawings TR L mit ComfoPipe Plus Maßskizze ComfoFond-L Q ComfoFond-L Q L TR with ComfoPipe Plus Maßskizze ComfoFond-L Q TR R mit ComfoPipe Plus ComfoFond-L Q R TR with ComfoPipe Plus 100 Maßskizze ComfoFond-L Q TR R mit ComfoPipe Plus 87
Open the catalog to page 43.2.3 Maßskizze ComfoFond-L Q TR L 3.2.3 Maßskizze ComfoFond-L Q TR L ComfoFond-L Q L TR 52 3.2.4 Maßskizze ComfoFond-L Q TR R ComfoFond-L Q R TR 3.2.4 Maßskizze ComfoFond-L Q TR R 52 SECTION P-P 495 SCALE 1 : 10 SECTION P-P SCALE 1 : 10
Open the catalog to page 5ComfoFond-L Q L ST 3.2.5 Maßskizze ComfoFond-L Q ST L
Open the catalog to page 63.2.6 Maßskizze ComfoFond-L Q ST R ComfoFond-L Q R ST
Open the catalog to page 7Elektrische Anschlüsse Der ComfoFond-L Q wird durch den ComfoAir COMFOFOND-L Q Q gesteuert und mit Strom versorgt. Hierzu muss der Temperatursensor und die Solepumpe des ComfoFond-L Q an die Option Box des ComfoAir Terminal diagram Q angeschlossen werden. Der Temperatursensor muss an die Klemmen, (Tge) und (GND) gekennzeichnet sind, angeschlossen werden. Der Sensor ist verpolungssicher. Die Solepumpe wird an den Klemmblock der Option Box angeschlossen. 6a = ComfoFond-L Q sensor 6b = ComfoFond-L Q pump 13 = Mains power supply 8
Open the catalog to page 8Pressure losses and collector selectionComfoFond-L Q pressure loss on air side Ground type Pump stage Air volume [m3/h] ComfoFond-L Q filter = G4; ComfoAir Q filter = No filter ComfoFond-L Q filter = G4; ComfoAir Q filter = No filter Ground type Pump stage Content of brine moisture protection approx. Ground type Pump stage Minimal requirements on the ground collector for pre-heating the outdoor air Zehnder ComfoAir Q350 TR Content of brine moisture protection approx. [l] The recommended collector examples named here are recommended minimum requirements, which may be increased depending on the...
Open the catalog to page 9CDE-FLYERTS085, V1016, en, subject to change without notice Zehnder Group Deutschland GmbH · Sales International · Almweg 34 · 77933 Lahr · Germany T +49 7821 586-392 · F +49 7821 586-406 [email protected] · www.international.zehnder-systems.
Open the catalog to page 103 Pages
8 Pages
10 Pages
2 Pages
6 Pages
2 Pages
2 Pages
12 Pages
3 Pages
8 Pages
6 Pages
2 Pages
4 Pages
4 Pages
48 Pages
29 Pages
2 Pages
2 Pages
2 Pages
2 Pages
5 Pages
12 Pages
6 Pages
8 Pages
8 Pages
7 Pages
3 Pages
5 Pages
3 Pages
7 Pages
3 Pages
20 Pages
36 Pages
92 Pages
16 Pages