1. Catalogs
  2. Xtratherm
  3. XtroLiner Partial Fill Cavity Wall [XO/CW]

XtroLiner Partial Fill Cavity Wall [XO/CW]

XtroLiner Partial Fill Cavity Wall  [XO/CW]

XtroLiner Partial Fill Cavity Wall [XO/CW]

Product catalog summary
Product Overview
Xtratherm XO/CW is a partial fill cavity wall insulation solution designed to achieve low U-values while maintaining a residual cavity for protection against wind-driven rain. It is suitable for both new builds and refurbishments, offering a high performance-to-thickness ratio.

Key Features
  • Class ‘O’ Modified PIR with a thermal conductivity of 0.021 W/mK.
  • HCFC/CFC free with zero ozone depletion potential.
  • Compressive strength greater than 125 kPa and water vapour resistivity over 100 MNs/gm.
  • Service temperature range from -20 to +100 ºC.

Specifications
  • Available in lengths of 1200mm, widths of 450mm, and thicknesses ranging from 50mm to 100mm.
  • Typical R-values range from 2.38 to 4.76 depending on thickness.

Installation Guidelines
  • Maintain a minimum residual cavity of 25mm for walls up to 12m, and 50mm for walls up to 25m.
  • Use approved stainless steel wall ties conforming to BS EN 845-1:2003.
  • Ensure tight fitting of insulation boards to maintain continuity.

Standards and Certifications
  • Manufactured to EN ISO 13165, with quality management systems approved to EN ISO 9001:2000 and environmental management to EN ISO 14001:2004.

Storage and Handling
  • Store off the ground on a clean, flat surface under cover.
  • Boards can be cut with a sharp knife or fine-toothed saw.

Applications
  • Suitable for cavity walls, rainscreen cladding, framing systems, soffits, roofs, and floors.
  • Can be combined with Xtratherm Thermal Liner Boards for enhanced U-values.

Contact Information
  • Xtratherm UK Limited, Chesterfield, Derbyshire, Tel: +44 (0) 371 222 1033
  • Xtratherm Limited, Navan, Co. Meath, Ireland, Tel: +353 (46) 906 6000
See more

Catalog excerpts

XtroLiner Partial Fill Cavity Wall  [XO/CW]-1

Class ‘O’ Modified PIR Insulation Fire Performance Thermal Conductivity Extensive Range Product Specifications Class ‘O’ Modified PIR Insulation Walls XO/CW Partial Fill Cavity Key Features Class ‘O’ Modified PIR Thermal Conductivity 0.021 W/mK HCFC/CFC Free Zero ODP Class ‘O’/Low Risk Fire Rating For New Build or Refurbishment

 Open the catalog to page 1
XtroLiner Partial Fill Cavity Wall  [XO/CW]-2

Product Specifications XO Partial Fill Cavity Our XtroLiner XO range of modified PIR offers excellent insulation performance with thermal conductivity of 0.021 W/mK and a Class ‘O’ fire rating. XtroLiner is CFC & HCFC free and is manufactured under the highest standards of ISO 9001 and 14001 Quality and Environmental Management Systems. The XtroLiner board has a core of modified polyisocyanurate (PIR) bonded to low emissivity textured aluminium foil facings. Partial Fill Cavity Insulation Insulation value Xtratherm XO/CW Partial Fill Cavity Wall insulation is the solution of choice to achieve...

 Open the catalog to page 2
XtroLiner Partial Fill Cavity Wall  [XO/CW]-3

Residual Cavity Wall Ties A Residual cavity is the air space retained when the Xtratherm XO/CW Partial Fill Cavity Wall insulation is placed in the cavity of a wall. For wall heights up to 12m a minimum 25mm cavity is recommended, and a minimum 50mm cavity for wall height greater than 12m, and up to and including 25m. The insulation should be secured to the outer face of the inner leaf by a retaining clip on approved double drip type stainless steel wall ties that conform to BS EN 845-1:2003. Xtratherm XO range is manufactured to EN ISO 13165 under quality systems approved to EN ISO 9001:2000...

 Open the catalog to page 3
XtroLiner Partial Fill Cavity Wall  [XO/CW]-4

Class ‘O’ Modified PIR Insulation Cavity Wall Partial Fill Floors Solid & Suspended Systems XtroLiner XO/CW is an insulation for cavity walls where a residual cavity has to be maintained. The excellent thermal performance of the XtroLiner allows for very good U-values to be achieved whilst minimizing overall cavity wall thickness. XO/CW can be combined with Xtrathem Thermal Liner Boards to achieve U-values down to Zero Carbon fabric standards in traditional wall thicknesses. XtroLiner XO/UF under floor insulation boards are used to reduce the thermal transmittance of ground supported and suspended...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.