Catalog excerpts
Fire Performance Thermal Conductivity Extensive Range Superior Performance Insulation Walls SR/TB-MF Insulation for Drylining Walls Mechanically Fixed to Battens Key Features Superior Performance Phenolic Thermal Conductivity as low as 0.020W/mK Low Smoke Obscuration HCFC/CFC Free Zero ODP Class ‘O’/ Low Risk Fire Rating For New Build or Refurbishment Fast Response Heating Superior performance phenolic insulation
Open the catalog to page 1SR Insulated Plaster Board Xtratherm Safe-R is a superior performance rigid insulation with enhanced fire performance, consisting of a Class ‘O’ phenolic foam core with negligible smoke obscuration. Safe-R is faced with low emissivity aluminium facings both sides, and has a thermal conductivity as low as 0.020W/mK. General The joints between Xtratherm ST/TB-MF boards should be taped and filled in accordance with drylining good practice. The Safe-R Thermal Liner boards achieve a resistance greater than 100MN.s/g. Improved vapour resistivity when required, can be provided with two coats of...
Open the catalog to page 2Standards Xtratherm Safe-R range is manufactured to EN ISO 13166 under Quality Systems approved to EN ISO 9001:2008 Quality Management, EN ISO 14001:2004 Environmental Management and BS OHSAS 18001 Health and Safety Management System. Installation Guidelines Mechanically Fixing SR/TB-MF Fix a pre-treated timber batten horizontally at ceiling level and another 20mm above the finished floor level. Fix vertical battens at max 600mm centres. Ensure battens are wide enough to offer 20mm support to all four edges of the plasterboard. Pack battens if necessary to level the wall. Trim all openings...
Open the catalog to page 3Superior performance phenolic insulation Superior Performance Insulation Xtratherm Technical Services All the members of our technical team are individually BBA accredited to help you reach your low energy goals. BBA qualified in U-value calculation, condensation risk and also Thermal Bridging 3D analysis backed by BRE accreditation – when you call Xtratherm, you can be assured you’re speaking to a qualified person. Walls Insulation for Partial Fill Cavity Wall Rainscreen Insulation for Rainscreen Application Walls Insulation for Drylining Walls Dot & Dab Roofs Insulation for Pitched Roofs...
Open the catalog to page 4All Xtratherm catalogs and technical brochures
-
Thin-R Hyfloor [XT/HYF]
4 Pages
-
Thin-R Flat Roof [FR/BGM]
4 Pages
-
Thin-R Tapered Roof [TR/BGM]
4 Pages
-
Thin-R Tapered Roof [TR/ALU]
4 Pages
-
Safe-R Pitched Roofs [SR/PR]
4 Pages
-
THIN-R® THERMAL PLY
4 Pages
-
THIN-R® FLAT ROOF MG
4 Pages
-
THIN-R® FLAT ROOF ALU
4 Pages
-
THIN-R® SARKING
4 Pages
-
THIN-R® PR BOARD
4 Pages
-
WALK-R®
4 Pages
-
THIN-R® UNDER FLOOR
4 Pages
-
CAVITY PLUS WALL (UK)
4 Pages
-
CAVITY WALL (IRL)
4 Pages
-
THERMAL LINER
4 Pages
-
TIMBER FRAME
8 Pages
-
Safe-R Soffit Plus [SR/STP]
4 Pages
Archived catalogs
-
Xtroliner
4 Pages
-
THIN-R® FLAT ROOF BG
4 Pages
-
THIN-R® RAFTERLOC (IRL)
4 Pages
-
THIN-R® HYFLOOR 100 (IRL)
4 Pages
-
THIN-R® UNDERFLOOR (UFH)
4 Pages
-
CLOSE-R
4 Pages
-
CAVITY WALL (UK)
4 Pages