1. Catalogs
  2. WOODN GREENWOOD srl
  3. Technical Brochure WoodN&Greenwood USA

Technical Brochure WoodN&Greenwood USA

Technical Brochure WoodN&Greenwood USA
1 / 138 PagesView full catalog

Technical Brochure WoodN&Greenwood USA

Product catalog summary
Disclaimer and General Notes: The document provides indicative information about WoodN Industries' products, emphasizing that US measurements are approximate due to metric conversions. It highlights that the document's content is not a guarantee of product features or performance and advises consulting the latest version on their website. The document also notes that WoodN materials lack structural characteristics and should not be used improperly.
Product Overview: The brochure covers various WoodN products including Sunscreen (VERSATILIS), Decking (GREENDECK and EVODECK), Cladding/Ceiling (MODULATUS), and Indoor Cladding (ORNANS). Each product is designed for specific applications such as energy-efficient buildings, outdoor environments, and aesthetic cladding solutions.
Technical Specifications: The document details mechanical properties, fire resistance, chemical features, and environmental impact of the materials. Key specifications include elasticity, water absorption, thermal expansion, tensile strength, flammability, and formaldehyde emission. The materials meet various international standards and are suitable for specific building codes.
Profiles Section: This section lists the dimensions, reinforcement details, and weights of various WoodN profiles. It advises using metric measurements for accuracy and provides standard lengths and nominal dimensions for each profile type.
Installation Instructions: Key installation guidelines include storing materials properly, acclimating them to jobsite temperatures, and ensuring installation temperatures above 32°F. The document stresses the importance of handling profiles carefully, preventing dirt accumulation, and following specific procedures for fixed and floating points to accommodate thermal expansion.
Assembly and Maintenance: The brochure provides detailed instructions on assembly center-to-center distances, emphasizing the need for mechanical systems to join substructures to metal reinforcements. It also outlines the importance of creating fixed and floating points to prevent material deformation and misalignment.
Specifications: WoodN profiles exhibit an initial dimensional shrinkage of less than 0.4% upon first exposure, as per EN 479: 1995 standards. They also undergo linear contraction and expansion due to temperature changes. Specific expansion gaps are recommended based on temperature conditions.
Installation Guidelines: It is crucial to follow the FIXED POINT positioning diagram to maintain expansion spaces over time. For applications involving corners or vertical mounting, specific fixed point placements are advised. Installation must be performed by specialized personnel, adhering to the provided technical instructions and using recommended adhesives and accessories.
Reinforcement Requirements: All Versatilis applications require internal metal reinforcement (aluminum/steel) tailored to each WoodN profile. The reinforcement profile should be shorter than the WPC profile, with specific measurements provided for profiles with WoodN closing caps. Failure to use proper reinforcement can lead to material deformation.
Profile Dimensions and Spans: The document includes detailed tables listing profile codes, reinforcement dimensions, and maximum horizontal and vertical spans. These spans are calculated considering permanent and non-permanent deformations under standard wind loads. The tables emphasize using metric measurements, with US values as approximate.
Warnings and Recommendations: WoodN Industries disclaims liability for improper installation not following the specified guidelines. Customers are responsible for sizing components according to current regulations. For special requirements, contact the technical department.
Fixing Systems: Various fixing systems are illustrated with axonometric, horizontal, vertical, and front section views. Key points for design and mounting include metal reinforcements, fixed points, and floating points. All components must be verified by a qualified technician.
Installation Procedures: Instructions for creating holes in aluminum profiles and installing threaded inserts are provided. The process involves using a pneumatic or electric riveting tool.
End Caps: Details on compatible profiles and installation instructions for Woodn interlocking caps are included. The caps are made of Woodn material and require adhesive strips and mechanical fastening for secure installation.
Material Features: The document outlines the mechanical properties, fire reaction, and chemical resistance of the materials used. It includes specific values for flexural strength, tensile strength, and impact resistance.
Plank Dimensions and Logistics: Specifications for outdoor decking planks, including dimensions, weight, and installation guidelines, are provided. The document emphasizes the importance of correct installation to prevent material deformation.
General Installation Instructions: Key points for storing, handling, and installing materials are highlighted. The document stresses the need for acclimatization, proper handling, and maintaining expansion gaps between profiles.
Installation on Stable Ground: The document outlines the procedure for installing aluminum joists on stable and drillable surfaces such as concrete sub-bases and existing stone floors. It emphasizes the importance of checking the thickness of concrete screeds to avoid damaging waterproofing membranes. For different ground conditions, consultation with Woodn Industries' technical department is recommended.
Laying Pattern: The recommended pattern is a running bond with a maximum center-to-center distance of 500 mm (≈ 20 inches) between joists. The document provides detailed steps for drilling and fixing joists, ensuring proper spacing for rainwater outflow.
Installation of Planks: Planks should be installed with the brushed side facing upwards. The document details the use of specific clips and screws for securing the planks, including instructions for creating screw holes and ensuring natural movement of the boards.
Double Frame Installation: For unstable or elevated grounds, a double frame system is recommended. This involves creating a frame with aluminum joists and crosspieces without fixing to the ground, suitable for surfaces like soil with vegetation or waterproofed floors.
Aluminum Frame and Supports: Instructions are provided for creating the aluminum frame and placing raising supports, with specific measurements for center-to-center distances and support placements.
Installation Specifications:
1. Board Spacing: Maintain a 1/4” gap for 6’ boards, increasing with board length. For direction changes, a 7/16” gap is required.
2. Support Requirements: Each board, including those shorter than 20”, must be supported at least at three points.
3. Tools Required: Impact drill, electric screwer, electric saw, rubber mallet, and tracing materials.
Laying Method 1 - Single Frame:
1. Suitable for stable, drillable surfaces like concrete and stone floors.
2. Joists should be fixed mechanically to the ground with a maximum center-to-center distance of 400 mm (≈ 16”).
3. Ensure a minimum gap of 5 mm (≈ 3/16”) between joist ends for drainage.
Laying Method 2 - Double Frame:
1. Suitable for unstable or elevated grounds, such as soil or gravel.
2. Involves creating a frame with aluminum joists and crosspieces without ground fixing.
3. Maximum center-to-center distance for joists is 400 mm (≈ 16”) and for crosspieces is 500 mm (≈ 20”).
Installation of Planks:
1. Install brushed side up for aesthetic effect.
2. Use starting clips and self-drilling screws for fixing.
3. Allow for natural board movement by enlarging screw holes.
Material Features:
1. Mechanical Properties: Elasticity and yield strength are specified under different temperatures.
2. Fire Reaction: Classified under various standards, including UL94 and ASTM E84.
3. Environmental Resistance: Low water absorption and resistance to microorganisms.
General Installation Instructions:
1. Store materials on a flat, stable surface in a dry area.
2. Acclimate materials to jobsite temperature for 48 hours before installation.
3. Maintain expansion gaps based on temperature and plank length.
Overview: This document provides detailed specifications, assembly instructions, and component details for various Woodn outdoor cladding systems. It includes information on laying patterns, alignment recommendations, and specific profiles used in construction.
Specifications: The document outlines nominal dimensions and weights for different plank profiles, with a focus on outdoor cladding. Length tolerances are specified according to UNI EN-ISO 22768 standards. The profiles include Q9510, Q13010HD, Q20410, TH14830HD-4, and TH6050HD, each with specific dimensions and weights.
Assembly Instructions: Detailed steps are provided for installing the cladding systems, including screwing aluminum joist profiles, applying clips, fitting planks, and installing fixed points. Specific instructions are given for different profiles, emphasizing the importance of choosing appropriate screws and wall plugs based on wall support types.
Mounting System: The document recommends using metric values for accuracy, with US values considered approximate. It provides weight specifications for the system with and without substructure, considering a standard wind load of 24.59 pounds per square foot.
System Components: The document lists components required for installation, including profiles, substructure profiles, fixing clips, screws, dowel pins, and rubber seals. It specifies the number of components needed per square foot for different bond types (stacked and running bond).
Details for Corners: Special attention is given to corner components, with warnings about material incidences based on European standards. It advises designing a cutting plan for installations deviating from the standard to ensure accurate component identification.
Additional Notes: The document includes diagrams and tables illustrating profile dimensions, assembly steps, and component layouts. It emphasizes the importance of aligning and plumbing the substructure before installation and leaving expansion joints for building settling.
Assembly Instructions:
1. Fix the ZSSW-LG bars directly to the ceiling using appropriate screws and wall plugs, or lower the structure with suitable hangers. Ensure the structure is perfectly aligned.
2. Install the first profile (TH5025HD, TH3050HD, TH6050HD, TH9050HD, or TH14830HD-4) to the substructure.
3. Attach the plank to the substructure and repeat the steps for additional planks.
4. For outdoor installations, ensure the ceiling perimeter is closed on all sides.
System Components:
- Profiles: TH5025HD, TH3050HD, TH6050HD, TH9050HD, TH14830HD-4
- Substructure Profiles: ZSSW-LG4213V, ZSSW-LG9433V, ZSSW-LG9637V, ZSSW-LG3326V
- Accessory Closing Piece: THZ5004HD (optional)
Weight Specifications:
- System weight varies depending on the profile and whether the accessory piece THZ5004HD is used.
- Example: TH6050HD without THZ5004HD ≈ 2.16 lb/sqft; with THZ5004HD ≈ 2.77 lb/sqft.
Installation Notes:
- Hangers, screws, and wall plugs are not included.
- For non-standard installations, a cutting plan is required to determine the number of clips and screws needed.
Material Features:
- Mechanical properties include elasticity and yield strength.
- Reaction to fire and flammability ratings are provided.
- Chemical and biological features such as water absorption and heavy metal content are specified.
General Installation Instructions:
- Store materials on a flat surface in a dry, clean area, protected from frost and direct sunlight.
- Check materials carefully before installation.
Handling and Storage:
  • Store materials on a flat, stable surface in a dry, clean area, protected from frost and direct sunlight.
  • Inspect materials for manufacturing issues before installation; complaints are not accepted post-installation.
  • Acclimate materials to jobsite temperature for at least 48 hours before installation.
  • Installation temperature must exceed 32°F.
  • Avoid covering products with non-breathable materials; use breathable materials like painter felt sheets.
  • Handle profiles with care to prevent damage; use clean fabric gloves.
Preparation of the Base:
  • Ensure the stability of the support surface; irregularities can affect installation success.
  • Check for cleanliness and absence of moisture before applying adhesive.
Adhesive Application:
  • Use appropriate adhesives based on substrate type; WoodN Industries is not responsible for bonding methods.
  • Apply adhesive with a trowel with triangular teeth; replace trowel if worn.
Wall Application:
  • Ensure a smooth wall surface; apply adhesive evenly and fix planks to prevent slippage.
  • For outdoor applications, use planks ≤ 500 mm in length.
Tips for Laying:
  • Lay planks perpendicularly to the surface; apply pressure evenly.
  • Remove excess adhesive promptly.
Routine Maintenance:
  • Material is water-resistant; clean with water, neutral soap, or alcohol.
  • Avoid solvents like acetone; use non-abrasive tools for cleaning.
Cleaning and Maintenance:
  • Regular cleaning recommended; use pressure water and neutral detergent.
  • Remove stains promptly to prevent absorption and discoloration.
Disclaimer:
  • US measurements are approximate; information is indicative and subject to change.
  • WoodN Industries is not liable for improper use of materials.
See more

Catalog excerpts

Technical Brochure WoodN&Greenwood USA-2

SPECIES UNICA DISCLAIMER - GENERAL NOTES Due to conversion from metric sizes and measurements, the US values provided are approximate. The information provided by WoodN Industries in this document are solely indicative, they are based on the present state of knowledge and must be considered only as a description of our products and their possible application. Such information must not be interpreted as a guarantee of specific features, performances or warranties of the product. Material’s colors and finishes represented in this document are the result of printing techniques so they may slightly...

 Open the catalog to page 2
Technical Brochure WoodN&Greenwood USA-3

Sunscreen - VERSATILIS Decking - GREENDECK Decking - EVODECK Cladding/Ceiling - MODULATUS Indoor cladding - ORNANS Handling, cleaning and maintenance notes Colors and finishes SPECIES UNICA

 Open the catalog to page 3
Technical Brochure WoodN&Greenwood USA-4

WOODN VERSATILIS: VERTICAL BEAUTY LOUVERS: VARIOUS PROPOSALS FOR COUNTLESS SOLUTIONS. IT IS A SUNSCREEN FOR POSITIVE ENERGY BUILDINGS, GUARANTEEING REDUCED CONSUMPTION AND LIVING COMFORT. ASSEMBLED WINDOWS AND SCREENS: AS YOU LIKE, SEVERAL COMPOSITIONS AND DESIGNS. pergolas - fences FENCES AND PERGOLAS: A READY-MADE SOLUTION, EASY TO ASSEMBLE AND SAFE. GREENWOOD GREENDECK AN ULTIMATE SOLUTION FOR OUTDOOR ENVIRONMENTS, IT LEAVES NO SPLINTERS. IT IS CERTIFIED SLIP-RESISTANT, REQUIRES LESS MAINTENANCE THAN WOOD, AND IT IS DIMENSIONALLY STABLE. WOODN MODULATUS: TOTAL LOOK outdoor cladding - CLADDING:...

 Open the catalog to page 4
Technical Brochure WoodN&Greenwood USA-5

WOODN VERSATILIS SPECIES UNICA

 Open the catalog to page 5
Technical Brochure WoodN&Greenwood USA-6

Hotel Le Massif Courmayeur (TZ9555-R) DISCLAIMER - GENERAL NOTES Due to conversion from metric sizes and measurements, the US values provided are approximate. The information provided by WoodN Industries in this document are solely indicative, they are based on the present state of knowledge and must be considered only as a description of our products and their possible application. Such information must not be interpreted as a guarantee of specific features, performances or warranties of the product. Material’s colors and finishes represented in this document are the result of printing techniques...

 Open the catalog to page 6
Technical Brochure WoodN&Greenwood USA-7

MATERIAL’S FEATURES Mechanical properties Elasticity (bending) Yield strenght (flexural) Dynamic- Mechanical analysis of transition temperature Linear thermal expansion coefficient (from 14 °F to 158 °F) longitudinal 46,9 x10-6 m/(m°C) trasversal 48 x10-6 m/(m°C) Tensile strenght and tensile strenght after accelerated weathering (exposure to xenon lights) ASTM D638-10 (tensile test) ASTM G155-050 Water absorbption and humidity difference after 2 months of exposure ~5,21% difference after 3 months of exposure ~6,9% (meet the requirements to comply with Miami Dade and Florida Building Code 2014)...

 Open the catalog to page 7
Technical Brochure WoodN&Greenwood USA-8

PROFILES SECTION Woodn recommends to refer only to the values expressed in mm the US values are to be considered approximate). reinforcement external nominal dimensions [ft, in] weight of the plank [lb/ft] section 40 x 30 mm (≈ 1”5/8 x 1”3/16) standard length 1830 mm (≈ 6’) section 50 x 26 mm (≈ 2“x 1”1/16) standard length 1830 mm (≈ 6’) section 60 x 32 mm (≈ 2“3/8 x 1”5/16) standard length 1830 mm (≈ 6’) section 70 x 40 mm (≈ 2“13/16 x 1”5/8) standard length 1830 mm (≈ 6’) section 70 x 40 mm (≈ 2“13/16 x 1”5/8) standard length 1830 mm (≈ 6’) section 70 x 40 mm (≈ 2“13/16 x 1”5/8) standard length...

 Open the catalog to page 8
Technical Brochure WoodN&Greenwood USA-9

Woodn recommends to refer only to the values expressed in mm the US values are to be considered approximate). reinforcement external nominal dimensions [ft, in] weight of the plank [lb/ft] section 95 x 55 mm (≈ 3”3/4 x 2”3/16) standard length 1830 mm (≈ 6’) TZ9555 section 95 x 55 mm (≈ 3“3/4 x 2”3/16) standard length 1830 mm (≈ 6’) JF11020 section 110 x 20 mm (≈ 4“3/8 x 13/16”) standard length 1830 mm (≈ 6’) JF12058-A section 120 x 58 mm (≈ 4“3/4 x 2”5/16) standard length 1830 mm (≈ 6’) JF18041 section 180 x 41 mm (≈ 7“1/8 x 1”5/8) standard length 1830 mm (≈ 6’) JF18041-165x30 section 180 x 41...

 Open the catalog to page 9
Technical Brochure WoodN&Greenwood USA-10

Woodn recommends to refer only to the values expressed in mm the US values are to be considered approximate). reinforcement external nominal dimensions [ft, in] weight of the plank [lb/ft] section 70 x 70 mm (≈ 2”13/16 x 2”13/16) standard length 1830 mm (≈ 6’) section 113 x 113 mm (≈ 4”1/2 x 4”1/2) standard length 1830 mm (≈ 6’) section 180 x 180 mm (≈ 7“1/8 x 7”1/8) standard length 1830 mm (≈ 6’) section 152 x 38 mm (≈ 6“ x 1”1/2) standard length 1830 mm (≈ 6’) section 200 x 58 mm (≈ 7”7/8 x 2”5/16) standard lenght 1830 mm (≈ 6’) section 350 x 68 mm (≈ 1’ 1”3/4 x 2”11/16) standard lenght 1830...

 Open the catalog to page 10
Technical Brochure WoodN&Greenwood USA-11

Woodn recommends to refer only to the values expressed in mm the US values are to be considered approximate). reinforcement external nominal dimensions [ft, in] weight of the plank [lb/ft] section Ø 50 mm (≈ Ø 2”) standard length 1830 mm (≈ 6’) nominal dimensions [ft, in] section 150 x 45 x 25 mm (≈ 5“15/16 x 1”13/16 x 1”) standard length 1830 mm (≈ 6’) The external dimensions listed are nominal values. The weights of the planks indicated in the tables are indicative and not binding. The final weight depends on the gauge and size of the internal reinforcement. Length tolerances according UNI...

 Open the catalog to page 11
Technical Brochure WoodN&Greenwood USA-12

GENERAL INSTALLATION INSTRUCTIONS Key points to be followed before and during the installation process: • Store the material on a flat surface providing for a stable support on the whole surface, in a dry, clean area, protected from frost and direct sun light. • Before starting the installation, carefully check the material and notify immediately of any manufacturing issues. Complaints will not be accepted after installation. • Before starting the installation, check project’s drawings (or shop drawings if provided) and the correspondence of the received material against the packing list. • Acclimate...

 Open the catalog to page 12

All WOODN GREENWOOD srl catalogs and technical brochures

  1. TH3050HD

    2  Pages

  2. JF18041

    1  Page

  3. EVODECK

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.