Solar technology
16Pages

{{requestButtons}}

Catalog excerpts

Solar technology - 1

Technical documentation Solar technology Flat-plate collectors CFK-1/TopSonF3-1/F3-Q Vacuum tube collector CRK • Swimming pool absorber *Hinweis: Jetzt Nachfolgemodell TopSon F3-1 mit noch besseren technischen Werten sowie Nachfolge-Speichermodel SEM-2-300

Open the catalog to page 1
Solar technology - 2

TopLine / ComfortLine High performance flat-plate collectors TopSon F3-1 / F3-Q High performance flat-plate collector CFK-1 for solar heating systems used for DHW heating for solar heating systems used for central heating backup Benefits of the Wolf high performance flat-plate collectors at a glance: • High performance flat-plate collectors tested to EN 12975 part 2 with top energy utilisation; the minimum yield for grants/subsidies [Germany] has been certified • Certified in accordance with Solar-Keymark (F3-1) • The conditions set for the “Blue Angel“ certificate of environmental...

Open the catalog to page 2
Solar technology - 3

ComfortLine High performance CRK vacuum tube collectors for solar heating systems used for DHW heating for solar heating systems used for central heating backup CRK benefits at a glance: • Solar-Keymark certified • The CRK collectors meet the requirements set for the “blue Angel“ certificate of environmental excellence acc. to RAL UZ 73 1390 100 • Powerful: High performance on the smallest of footprints; high yields particularly during spring and autumn; especially suitable for a combination of DHW heating and central heating backup 0 • Durable: Direct flow collector designed similar to a...

Open the catalog to page 3
Solar technology - 4

Swimming pool absorber Economic solution for efficiently heating swimming pool water Benefits of the swimming pool absorber at a glance: • Low investment and operating costs • Long service life through robust absorber tubes • Scale and dirt-repellent absorber system • High energy yields through the utilisation of solar and environmental energy • UV and weather-resistant • Small attack areas for gusts of wind • Compact panel dimensions of 3.23 m x 1.24 m • 5 year warranty Specification A B 4 Swimming pool absorber Length Width Operating temperature Permissible operating pressure at 20°C...

Open the catalog to page 4
Solar technology - 5

Control units TopLine solar technology Solar module SM1 • Extension module for the regulation of one solar circuit • In conjunction with Wolf boilers, greater energy saving through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sufficient solar yield • Capturing the amount of heat with an external calorimeter • function check of flow rate and gravity brake • Display of the set and actual values on the BM programming module, BM-solar • eBus interface • Rast-5 connection technology Incl. one collector sensor (PT 1000) and one storage sensor (NTC 5K) each with...

Open the catalog to page 5
Solar technology - 6

Freestanding cylinder SEM-1 / SEM-2 with two indirect coils for SEM-2, the solar pump assembly can be fitted directly to the cylinder Freestanding steel cylinder with quality certificate, heating water max. 110°C and 10 bar, DHW max. 95°C and 10 bar Benefits of the Wolf SEM-1: • Solar cylinder made from steel with two enamel-coated indirect coils to DIN 4753 • Highly-effective thermal insulation and low thermal losses through high-grade hard PU foam insulation below the cylinder foil casing • The interior of the cylinder and the indirect coils are protected by enamel coating and a...

Open the catalog to page 6
Solar technology - 7

Pipework layout Solar DHW heating with the SEM-... solar cylinder 2 3 1 4 °C °C eBus 5 °C °C bar 8 10 6 7 9 1 Collector array 6 Solar control unit cylinder sensor 2 Air vent trap 7 Fill & drain valve 3 Collector sensor 8 Solar cylinder SEM-... 4 Temperature differential control unit (e.g. SM1) 9 Boiler with control R2 5 Pump/fitting assembly 10 Cylinder sensor, heating water Please see our „Cylinder systems“ documentation for further cylinder solutions with Wolf solar heating. 7

Open the catalog to page 7
Solar technology - 8

Accessories TopLine solar technology Pump/fitting assembly comprising: 2 x multi-valves with Ø18 mm (Ø22 mm for solar pump assembly 20) locking ring fittings, each with a gravity brake in the flow and return; can be installed with air grille, two integral dial thermometers, one 6 bar safety valve, one 0-10 bar pressure gauge. Pump/fitting assembly to connect a second heat consumer, comprising: Multi-valve with gravity brake, can be installed with air grille, integral dial thermometer, one 1” ball valve, EPP insulation, temperature-resistant up to 130 °C. With integral solar circuit pump....

Open the catalog to page 8
Solar technology - 9

Technical information Example: Climate zone Munich Roof inclination 45°, collector orientation SE DHW demand (approx. 75 l / person / day) Number of occupants: 4 Helsinki Stockholm Tallinn Riga Copenhagen Vilnius Dublin Amsterdam London Warsaw Berlin Brussels Parague Luxembourg Paris Bratislava Munich Vienna Budapest Ljubljana Bucharest Sofia Rome Madrid Lisabon Athens Nicosia Valletta Climate zone Roof orientation Climate zone Minimum hours of sunshine 1 1900 - 2000 2 1800 - 1900 3 1700 - 1800 4 1600 - 1700 5 1500 - 1600 Roof inclination Hot water requirement Low Standard 0.6 Number of...

Open the catalog to page 9
Solar technology - 11

The system professional for heating, air conditioning, ventilation and solar technology 11

Open the catalog to page 11
Solar technology - 13

Wolf solar technology Control units for high performance solar collectors: No. Price each Total price Solar module SM1 Extension module for the regulation of one solar circuit in conjunction with Wolf boilers Solar module SM2 Extension module for the regulation of a solar system including up to 2 cylinders and 2 collector fields in conjunction with Wolf boilers Programming module BM-Solar Required for a solar module SM1 or SM2 when used as an independent solar control (Stand-Alone operation) Programming module BM-Solar Grafik Usable for SM1 and SM2 alternatively to BM-Solar Solar cylinder...

Open the catalog to page 13
Solar technology - 14

Wolf solar technology F3-1 CFK-1 F3-Q CRK Return temperature raising facility MM or SM2 for tying the solar energy into the heating circuit • • • Roof integration set “Interlocking tiles/slate/barrel roof tiles” for 1 collectors roof integration frames for an architecturally attractive roof integration of the collectors into the tile surface, powder-coated, dark grey RAL 7021. • Roof integration set “Interlocking tiles/slate/barrel roof tiles” for 2 collectors roof integration frames for an architecturally attractive roof integration of the collectors into the tile surface, powder-coated,...

Open the catalog to page 14