1. Catalogs
  2. WOLF
  3. Roof Extract Fans / Ventilation Hoods

Roof Extract Fans / Ventilation Hoods

Roof Extract Fans / Ventilation Hoods
1 / 44 PagesView full catalog

Roof Extract Fans / Ventilation Hoods

Product catalog summary
Roof Extract Fans DV
  • Product Review: The DV series fans are designed for both vertical and horizontal discharge of slightly polluted air. They feature integral drive motors with thermal protection and are constructed from galvanized sheet steel with aluminum impellers.
  • Specifications: These fans operate within a temperature range of -20°C to +40°C and come with isolator switches. They are available in various sizes, with performance ranging from 445 to 34,550 m³/h.
  • Safety and Standards: Compliance with DIN EN 294 safety standards is ensured, with additional inlet guards required if accidental contact with the impeller is possible. Performance data is measured according to DIN 24 163-2, and noise levels are evaluated per DIN 45 635 - 38.
  • Sound Data: Sound power levels are provided for both intake and discharge, with recommendations for duct configurations to minimize noise and pressure losses.
Ventilation Hoods DLH
  • Product Review: Details on dimensions and pressure drops for intake and exhaust are provided, along with accessory dimensions.
Smoke Extract Fans ER
  • Product Review: Similar to the DV series, these fans are designed for smoke extraction with specific performance and dimension data provided for various models.
  • Specifications: Includes isolator switches and accessory dimensions, with sample specifications available for reference.
Overview: The document provides detailed technical specifications and data for roof ventilation hoods and smoke extract fans, focusing on their design, performance, and compliance with safety standards.
Roof Ventilation Hoods DLH:
  • Constructed from galvanized sheet steel, these hoods serve as weatherproof ventilation openings or as terminal elements in ventilation systems.
  • Key dimensions and pressure loss data are provided for various models (DLH 40, 56, 71, 90, 125).
  • Accessories and additional components are detailed, including dimensions and specifications for different configurations.
Smoke Extract Fans ER:
  • Designed for heat and smoke extraction during fires, these fans help maintain smoke-free escape routes and facilitate firefighting.
  • Models RDM 56 and RDM 57 are certified to meet EN 12101-3 standards, with temperature resistance up to +600°C for 120 minutes.
  • Technical data includes flow rates, pressure, voltage, speed, motor specifications, and sound power levels.
  • Safety features include compliance with DIN EN 294 for safety guards and DIN 24 166 for technical specifications.
Performance and Safety:
  • Performance curves and sound data are provided, with emphasis on noise levels and attenuation across different frequencies.
  • Installation and maintenance guidelines stress the importance of adhering to safety standards and using heat-protected cables.
Overview: The document provides detailed technical specifications and operational guidelines for various models of smoke extract fans, specifically the RDM 56/57 series. It includes information on flow rates, pressure, voltage, motor speed, and sound levels, as well as dimensions and installation instructions.
Specifications: Each fan model is described with its flow rate in cubic meters per hour (m³/h), available pressure in Pascals (Pa), voltage rating, motor speed in revolutions per minute (1/min), power consumption in kilowatts (kW), current in amperes (A), and weight in kilograms (kg). The document also specifies the isolator switch model for each fan.
Sound Levels: The A-weighted sound power level (LWA) is provided for each fan model, measured according to DIN 45635-38 standards. The document includes sound attenuation data for silencers at various frequencies, indicating the reduction in decibels (dB).
Installation and Dimensions: Detailed dimensions for each fan model are provided, including information on flat roof upstands, flexible connections, mating flanges, and silencers. The document specifies the pressure loss through silencers at different flow rates.
Operational Guidelines: The document outlines the function of isolator switches, which are used to safely disconnect the fan from the mains for maintenance. It also describes the optical smoke detector EBS 02, which detects smoke using the Tyndall effect and includes a temperature sensor for additional safety.
Standards and Certifications: The smoke extract fans are tested and certified according to EN 12101-3 and DIBt standards, ensuring they are suitable for high-temperature operations up to 600°C for 120 minutes.
Specifications:
The document describes a centrifugal impeller with backward curved blades made of steel, which are welded and coated. All mechanically stressed parts are made of galvanized sheet steel. The motor is separated from the air stream and cooled by outside air, with additional thermal isolation in the motor cabinet. The roof fans adhere to the tolerances of Class 2 of DIN 24 166 "Fans, Technical Specifications."

Technical Parameters:
  • Flow rate: Specified in m3/h
  • Pressure increase: Specified in Pa
  • Temperature of gas medium: Specified in °C
  • Speed: Specified in 1/min
  • Motor rating: Specified in kW
  • Voltage/frequency: Specified in V/Hz
  • A-Sound power level: Specified in dB
  • Weight: Specified in kg
  • Dimensions: Specified in mm

Accessories (at extra cost):
  • Flat roof upstand ZBS
  • Flat roof upstand ZBS 20 (only RDM 56, for duct connection, up to size 7190)
  • Silencer upstand ZDS 32 (up to size 7190)
  • Flexible Connection ZKE
  • Mating flange ZKF
  • Isolator switch
  • Smoke detector switch panel (on request)
  • Optical smoke detector
  • Mounting plate for smoke detector
  • Manual switch

Contact Information:
Wolf GmbH, Postfach 1380, D-84048 Mainburg, Tel.: 087 51 / 74-0, Fax: 087 51 / 74-1600, Internet: www.wolf-heiztechnik.de

Part Number: 48 00 135
Note: Subject to modifications.
See more

Catalog excerpts

Roof Extract Fans / Ventilation Hoods-1

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

 Open the catalog to page 1
Roof Extract Fans / Ventilation Hoods-3

3 Roof Extract Fans DV Technical Description Motors Well tried and tested integral drive motors are used. Noise-tested, maintenance-free deep-groove ball bearings give the motor long life. To avoid overheating, every motor is equipped with thermal contacts. This thermal protection has to be effective in operation in order to enable the user to claim for warranty in the case of break down. Please follow the instructions of the wiring diagram for connecting the thermal contacts correctly. Fan range DV 40-125 The fans of the range DV 40 - 125, for vertical discharge, are suitable for discharging...

 Open the catalog to page 3
Roof Extract Fans / Ventilation Hoods-5

5 All roof extract fans are supplied with a discharge-side mesh safety guard in accordance with DIN EN 294. The inlet side is not fitted with a standard guard, because it is normal practice to attach other system parts to the side. However, if the unit is installed in such a way that accidental contact with the impeller is possible, an additional inlet guard has to be fitted acc. to DIN EN 294! The fans may only be put into operation if all necessary protection devices are fitted and made effective (see maintenance instructions)! The safety guards are to be executed acc. to DIN EN 292 – 1, chapter...

 Open the catalog to page 5
Roof Extract Fans / Ventilation Hoods-9

9 ø12 286 440 M6 671 6×M6 138 DV 40 ZBS 23-0040 Flat roof upstand high ZBS 09-0040-# Upstand for inclined roof ZBS 11-0040 Soaker sheet (for corrugated roof) ZBS 20-0040 Flat roof upstand ZDS 20-0040 Silencer upstand ZDS 09-0040-# Silencer upstand for inclined roof ZKK 20-0040 Intermediate piece ZBU 01-0040-25 Connecting plate ZKE 11-0250 Intake flexible connection ZKF 11-0250 Mating flange ZLK 21-0250 Damper with actuator ZLK 01-0250 Automatic back draught damper Mains lead ZDH 20-0250 Discharge silencer 626 410 400 330 395 M10 710 ø11.5 330 386 M10 ø256 ø286 6×M6 618 378 618 330 150 150 378...

 Open the catalog to page 9
Roof Extract Fans / Ventilation Hoods-11

11 ø12 395 600 M8 881 8×M8 192 DV 56 ZBS 23-0056 Flat roof upstand high ZBS 09-0056-# Upstand for inclined roof ZBS 11-0056 Soaker sheet (for corrugated roof) ZBS 20-0056 Flat roof upstand ZDS 20-0056 Silencer upstand ZDS 09-0056-# Silencer upstand for inclined roof ZKK 20-056 Intermediate piece ZBU 01-0056-35 Connecting plate ZKE 11-0355 Intake flexible connection ZKF 11-0355 Mating flange ZLK 21-0355 Automatic back draught damper ZLK 01-0355 Automatic back draught damper Mains lead ZDH 20-0355 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type...

 Open the catalog to page 11
Roof Extract Fans / Ventilation Hoods-13

13 Dimensions DV 71 DV 71 ZBS 23-0071 Flat roof upstand high ZBS 09-0071-# Upstand for inclined roof ZBS 11-0071 Soaker sheet (for corrugated roof) ZBS 20-0071 Flat roof upstand ZDS 20-0071 Silencer upstand ZDS 09-0071-# Silencer upstand for inclined roof ZKK 20-0071 Intermediate piece ZBU 01-0071-45 Connecting plate ZKE 11-0450 Intake flexible connection ZKF 11-0450 Mating flange ZLK 21-0450 Damper with actuator ZLK 01-0450 Automatic back draught damper Mains lead ZDH 20-0450 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering ZBS...

 Open the catalog to page 13
Roof Extract Fans / Ventilation Hoods-15

15 Dimensions DV 90 DV 90 ZBS 23-0090 Flat roof upstand high ZBS 09-0090-# Upstand for inclined roof ZBS 11-0090 Soaker sheet (for corrugated roof) ZBS 01-0090 Flat roof upstand ZDS 20-0090 Silencer upstand ZDS 09-0090-# Silencer upstand for inclined roof ZKK 20-0090 Intermediate piece ZBU 01-0090-71 Connecting plate ZKE 11-0710 Intake flexible connection ZKF 11-0710 Mating flange ZLK 21-0710 Damper with actuator ZLK 01-0710 Automatic back draught damper Mains lead ZDH 20-0560 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering ZBS...

 Open the catalog to page 15
Roof Extract Fans / Ventilation Hoods-17

17 Dimensions DV 125 ø14 751 1270 M10 1769 8×M10 445 1556 1183 DV 125 ZBS 23-0125 Flat roof upstand high ZBS 09-0125-# Upstand for inclined roof ZBS 20-0125 Flat roof upstand ZDS 20-0125 Silencer upstand ZDS 09-0125-# Silencer upstand for inclined roof ZKK 20-0125 Intermediate piece ZBU 01-0125-71 Connecting plate ZKE 11-0710 Intake flexible connection ZKF 11-0710 Mating flange ZLK 21-0710 Damper with actuator ZLK 01-0710 Automatic back draught damper Mains lead ZDH 20-0710 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering ZBS...

 Open the catalog to page 17
Roof Extract Fans / Ventilation Hoods-18

18 Technical Data: Main Control Max. Max. Type Voltage voltage rating Current Weight Protection D1 400 V 230 V 3 kW - 0,9 kg IP 54 DS 400 V 230 V 4 kW - 0,9 kg IP 54 D5-1 400 V 230 V - 1 A 4,5 kg IP 40 D5-3 400 V 230 V - 2 A 7,0 kg IP 20 D5-7 400 V 230 V - 4 A 9,0 kg IP 20 D5-12 400 V 230 V - 7 A 19,0 kg IP 20 E5-1 230 V - - 1,5 A 1,0 kg IP 40 E5-3 230 V - - 3 A 4,0 kg IP 40 Dimensions: Type A B C D1 105 170 135 DS 105 170 135 D5-1 150 200 175 D5-3 230 310 185 D5-7 230 310 185 D5-12 230 310 185 E5-1 105 170 135 E5-3 150 200 175 Motor Protection Units Type Voltage max. Current Weight Protection...

 Open the catalog to page 18
Roof Extract Fans / Ventilation Hoods-20

20 T T L2 L1 L3 HiS HiS HiO HiO PE PE U1 V1 W1 W2 U2 V2 T 6 8 10 12 T 4 PE U1 V1 W1 W2 U2 V2 T T 15 16 13 14 3 4 11 12 9 10 7 8 5 6 1 2 05-08-02 527 509 T T L1 N HiS HiO HiO HiS PE Z2 Z1 U2 T T U1 PE 15 16 3 4 13 14 9 10 7 8 5 6 1 2 17-09-04 Isolator switch ESH 21/23-0030-25 for single-phase AC-motors, with capacitor and thermo-contacts white white orange black blue brown Mains isolator switch Motor capacitor Diagrams for Isolator Switches 508 PE U1 U2 Z1 T T Z2 1 2 5 6 7 8 3 4 PE HiS HiO HiO HiS N L1 17-09-04 Isolator switch ESH 21/23-0030-22 for single-phase AC-motors, with capacitor, thermo-contacts...

 Open the catalog to page 20
Roof Extract Fans / Ventilation Hoods-21

21 DigiPro Control Unit The control unit DigiPro is a system for controlling and monitoring a ventilation installation. DigiPro is fully set and ready for connection. The smallest unit is equipped with a manual control panel and a second part serving as master controller. These components are connected by bus (eBus) in a 2-wire technology. There up to 32 units can be integrated in the same bus-system (with always one master or group unit). 2 master units are available for the control and monitoring of exhaust fans and other units equipped with a 230V or 400V fan motor, 2-speed or continuous speed...

 Open the catalog to page 21
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.