video corpo

Roof Extract Fans / Ventilation Hoods
44Pages

{{requestButtons}}

Catalog excerpts

Roof Extract Fans / Ventilation Hoods - 1

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Open the catalog to page 1
Roof Extract Fans / Ventilation Hoods - 3

3 Roof Extract Fans DV Technical Description Motors Well tried and tested integral drive motors are used. Noise-tested, maintenance-free deep-groove ball bearings give the motor long life. To avoid overheating, every motor is equipped with thermal contacts. This thermal protection has to be effective in operation in order to enable the user to claim for warranty in the case of break down. Please follow the instructions of the wiring diagram for connecting the thermal contacts correctly. Fan range DV 40-125 The fans of the range DV 40 - 125, for vertical discharge, are suitable for...

Open the catalog to page 3
Roof Extract Fans / Ventilation Hoods - 5

5 All roof extract fans are supplied with a discharge-side mesh safety guard in accordance with DIN EN 294. The inlet side is not fitted with a standard guard, because it is normal practice to attach other system parts to the side. However, if the unit is installed in such a way that accidental contact with the impeller is possible, an additional inlet guard has to be fitted acc. to DIN EN 294! The fans may only be put into operation if all necessary protection devices are fitted and made effective (see maintenance instructions)! The safety guards are to be executed acc. to DIN EN 292 – 1,...

Open the catalog to page 5
Roof Extract Fans / Ventilation Hoods - 9

9 ø12 286 440 M6 671 6×M6 138 DV 40 ZBS 23-0040 Flat roof upstand high ZBS 09-0040-# Upstand for inclined roof ZBS 11-0040 Soaker sheet (for corrugated roof) ZBS 20-0040 Flat roof upstand ZDS 20-0040 Silencer upstand ZDS 09-0040-# Silencer upstand for inclined roof ZKK 20-0040 Intermediate piece ZBU 01-0040-25 Connecting plate ZKE 11-0250 Intake flexible connection ZKF 11-0250 Mating flange ZLK 21-0250 Damper with actuator ZLK 01-0250 Automatic back draught damper Mains lead ZDH 20-0250 Discharge silencer 626 410 400 330 395 M10 710 ø11.5 330 386 M10 ø256 ø286 6×M6 618 378 618 330 150 150...

Open the catalog to page 9
Roof Extract Fans / Ventilation Hoods - 11

11 ø12 395 600 M8 881 8×M8 192 DV 56 ZBS 23-0056 Flat roof upstand high ZBS 09-0056-# Upstand for inclined roof ZBS 11-0056 Soaker sheet (for corrugated roof) ZBS 20-0056 Flat roof upstand ZDS 20-0056 Silencer upstand ZDS 09-0056-# Silencer upstand for inclined roof ZKK 20-056 Intermediate piece ZBU 01-0056-35 Connecting plate ZKE 11-0355 Intake flexible connection ZKF 11-0355 Mating flange ZLK 21-0355 Automatic back draught damper ZLK 01-0355 Automatic back draught damper Mains lead ZDH 20-0355 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with...

Open the catalog to page 11
Roof Extract Fans / Ventilation Hoods - 13

13 Dimensions DV 71 DV 71 ZBS 23-0071 Flat roof upstand high ZBS 09-0071-# Upstand for inclined roof ZBS 11-0071 Soaker sheet (for corrugated roof) ZBS 20-0071 Flat roof upstand ZDS 20-0071 Silencer upstand ZDS 09-0071-# Silencer upstand for inclined roof ZKK 20-0071 Intermediate piece ZBU 01-0071-45 Connecting plate ZKE 11-0450 Intake flexible connection ZKF 11-0450 Mating flange ZLK 21-0450 Damper with actuator ZLK 01-0450 Automatic back draught damper Mains lead ZDH 20-0450 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering...

Open the catalog to page 13
Roof Extract Fans / Ventilation Hoods - 15

15 Dimensions DV 90 DV 90 ZBS 23-0090 Flat roof upstand high ZBS 09-0090-# Upstand for inclined roof ZBS 11-0090 Soaker sheet (for corrugated roof) ZBS 01-0090 Flat roof upstand ZDS 20-0090 Silencer upstand ZDS 09-0090-# Silencer upstand for inclined roof ZKK 20-0090 Intermediate piece ZBU 01-0090-71 Connecting plate ZKE 11-0710 Intake flexible connection ZKF 11-0710 Mating flange ZLK 21-0710 Damper with actuator ZLK 01-0710 Automatic back draught damper Mains lead ZDH 20-0560 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering...

Open the catalog to page 15
Roof Extract Fans / Ventilation Hoods - 17

17 Dimensions DV 125 ø14 751 1270 M10 1769 8×M10 445 1556 1183 DV 125 ZBS 23-0125 Flat roof upstand high ZBS 09-0125-# Upstand for inclined roof ZBS 20-0125 Flat roof upstand ZDS 20-0125 Silencer upstand ZDS 09-0125-# Silencer upstand for inclined roof ZKK 20-0125 Intermediate piece ZBU 01-0125-71 Connecting plate ZKE 11-0710 Intake flexible connection ZKF 11-0710 Mating flange ZLK 21-0710 Damper with actuator ZLK 01-0710 Automatic back draught damper Mains lead ZDH 20-0710 Discharge silencer # = inclination up to 45° possible within 5° steps. Indicate inclination with type when ordering...

Open the catalog to page 17
Roof Extract Fans / Ventilation Hoods - 18

18 Technical Data: Main Control Max. Max. Type Voltage voltage rating Current Weight Protection D1 400 V 230 V 3 kW - 0,9 kg IP 54 DS 400 V 230 V 4 kW - 0,9 kg IP 54 D5-1 400 V 230 V - 1 A 4,5 kg IP 40 D5-3 400 V 230 V - 2 A 7,0 kg IP 20 D5-7 400 V 230 V - 4 A 9,0 kg IP 20 D5-12 400 V 230 V - 7 A 19,0 kg IP 20 E5-1 230 V - - 1,5 A 1,0 kg IP 40 E5-3 230 V - - 3 A 4,0 kg IP 40 Dimensions: Type A B C D1 105 170 135 DS 105 170 135 D5-1 150 200 175 D5-3 230 310 185 D5-7 230 310 185 D5-12 230 310 185 E5-1 105 170 135 E5-3 150 200 175 Motor Protection Units Type Voltage max. Current Weight...

Open the catalog to page 18
Roof Extract Fans / Ventilation Hoods - 20

20 T T L2 L1 L3 HiS HiS HiO HiO PE PE U1 V1 W1 W2 U2 V2 T 6 8 10 12 T 4 PE U1 V1 W1 W2 U2 V2 T T 15 16 13 14 3 4 11 12 9 10 7 8 5 6 1 2 05-08-02 527 509 T T L1 N HiS HiO HiO HiS PE Z2 Z1 U2 T T U1 PE 15 16 3 4 13 14 9 10 7 8 5 6 1 2 17-09-04 Isolator switch ESH 21/23-0030-25 for single-phase AC-motors, with capacitor and thermo-contacts white white orange black blue brown Mains isolator switch Motor capacitor Diagrams for Isolator Switches 508 PE U1 U2 Z1 T T Z2 1 2 5 6 7 8 3 4 PE HiS HiO HiO HiS N L1 17-09-04 Isolator switch ESH 21/23-0030-22 for single-phase AC-motors, with capacitor,...

Open the catalog to page 20
Roof Extract Fans / Ventilation Hoods - 21

21 DigiPro Control Unit The control unit DigiPro is a system for controlling and monitoring a ventilation installation. DigiPro is fully set and ready for connection. The smallest unit is equipped with a manual control panel and a second part serving as master controller. These components are connected by bus (eBus) in a 2-wire technology. There up to 32 units can be integrated in the same bus-system (with always one master or group unit). 2 master units are available for the control and monitoring of exhaust fans and other units equipped with a 230V or 400V fan motor, 2-speed or continuous...

Open the catalog to page 21

All WOLF catalogs and technical brochures

  1. CGG-1K

    8 Pages

Archived catalogs

  1. TopOne

    8 Pages

  2. KG-Top

    228 Pages

  3. Unit heater LH

    60 Pages