Overview: The document outlines the specifications and features of ComfortLine's gas-fired condensing boilers, emphasizing energy efficiency and compliance with environmental standards. It details various models, including wall-mounted boilers and condensing centers, and provides technical specifications, benefits, and installation requirements.
Specifications:
  • Wall Mounted Boilers (CGB/CGB-K): These models have a modulation range for flow/return temperatures of 50/30°C, with outputs from 3.6 to 24.8 kW. They feature a sealed combustion chamber, high efficiency up to 110% (Hi), and a pivoting heat exchanger for easy maintenance.
  • Condensing Centers (CGS/CGW): These combine a boiler with a stainless steel DHW heat exchanger and stratification cylinder, offering high DHW performance and energy efficiency through innovative insulation and a 'DHW turbo' system.
  • High Capacity Boilers (CGB-35, -50, -75, -100): Suitable for larger installations, these models provide outputs up to 98.8 kW, featuring robust heat exchangers and easy maintenance and installation.
Key Features:
  • All models are DVGW certified and comply with German and European clean combustion directives.
  • Equipped with premix burners for natural gas and LPG, ensuring high efficiency and low emissions.
  • Installation and maintenance are simplified with accessible components and external flue gas test ports.
  • Designed for open and balanced flue operation, with cascade operation options for larger systems.
Installation and Maintenance:
  • Boilers are designed for easy installation with modular components and optional accessories for quick setup.
  • Maintenance is facilitated by pivoting heat exchangers and accessible cleaning ports.
  • Models can be split into modules for easier handling and installation in confined spaces.
Environmental and Efficiency Standards:
  • Boilers meet 'Blue Angel' certificate requirements for environmental excellence with natural gas operation.
  • High standard efficiencies are achieved, with up to 110% (Hi) and 99% (Hs) for optimal energy utilization.
Flue Systems Overview: The document provides technical specifications and installation guidelines for balanced flue systems in wall-mounted gas-fired condensing boilers, detailing configurations and necessary components.
Flue Specifications: It details flue connections, including DN 80 and DN 100 sizes, and their applications in balanced and open flue systems, specifying maximum lengths based on boiler models from 35 kW to 100 kW.
Installation Procedures: Emphasizes adherence to local building regulations and the use of original WOLF components for optimal performance, with instructions for adapting installations to regional requirements.
Standards and Certifications: References compliance with EN 13384 calculations and lists CE-certified flue pipes and components for safety and regulatory adherence.
Recommendations: Advises using original WOLF components for concentric routing of flues and consulting local heating engineers for installation queries.
Accessories: Lists control and hydraulic accessories, including programming modules, safety valves, and connection sets, with specific accessories for solar heating and DHW circulation.
Key Data: Includes tables with maximum flue lengths, fan draught specifications, and component part numbers, essential for planning and installation.
See more

Catalog excerpts

Gas combi boiler-1

The competence brand for energy saving systems ComfortLine Gas fired condensing boilers Wall mounted gas fired condensing boilers CGB / CGB-K Gas fired condensing centres CGS / CGW

 Open the catalog to page 1
Gas combi boiler-2

ComfortLine Gas fired condensing boilers Benefits of the WOLF gas fired condensing boilers up to 24 kW CGB / CGB-K / CGW / CGS • Gas fired condensing boilers, sealed combustion chamber, for open and balanced flue operation • Certified with the DVGW quality symbol; tested in accordance with German and European Directives; extremely clean combustion • High standard efficiency up to 110% (Hi) / 99% (Hs) for the best possible energy utilisation • Meets the requirements for the "Blue Angel" certificate of environmental excellence to RAL-UZ 61 when operated with natural gas • Premix burner for natural...

 Open the catalog to page 2
Gas combi boiler-3

ComfortLine Gas fired condensing boilers CGB-K-20, -24 wall mounted gas fired condensing boilers for DHW and central heating Wall mounted gas fired condensing boilers for DHW and central heating with integral stainless steel DHW heat exchanger • Modulation range for flow/return 50/30 °C: CGB-K-20 from 6.1 to 20.5 kW CGB-K-24 from 7.8 to 24.8 kW 855 • Booster output for DHW heating: CGB-K-20 22.9 kW CGB-K-24 27.6 kW • Wall mounted combi boiler easily retrofitted - optionally without cylinder or with cylinder CSW-120 440 393 CGW-20/120, -24/140 gas fired condensing centres with high performance...

 Open the catalog to page 3
Gas combi boiler-4

ComfortLine Gas fired condensing boilers CGS-20/160, -24/200 gas fired condensing centres with stainless steel DHW heat exchanger and enamelled steel stratification cylinder 393 Gas fired condensing centre, comprising a wall mounted gas fired condensing boiler with a stainless steel DHW heat exchanger and a stratification cylinder in modular design • Modulation range for flow/return 50/30 °C: CGS-20/160 from 6.1 to 20.5 kW CGS-24/200 from 7.8 to 24.8 kW • Booster output for DHW heating: CGS-20/160 22.9 kW CGS-24/200 27.6 kW 855 • The "Turbostop system" (patent applied for) provides a convenient...

 Open the catalog to page 4
Gas combi boiler-5

ComfortLine Gas fired condensing boilers CGB-35, -50 wall mounted gas fired condensing central heating boilers CGB-K40-35 wall mounted gas fired condensing boilers for DHW and central heating Wall mounted gas fired condensing central heating boiler CGB-35, -50, sealed combustion chamber, for open and balanced flue operation, may be combined with DHW cylinders, e.g. SE-2 855 Wall mounted gas fired condensing boiler CGB-K40-35 for DHW and central heating with integral stainless steel DHW heat exchanger, sealed combustion chamber, for open and balanced flue operation CGB SE-2 • Modulation range...

 Open the catalog to page 5
Gas combi boiler-6

ComfortLine Gas fired condensing boilers CGB-75, -100 wall mounted gas fired condensing central heating boilers Wall mounted gas fired condensing central heating boilers CGB-75, -100, sealed combustion chamber, for open and balanced flue operation, may be combined with DHW cylinders, e.g. SE-2 • Modulation range for flow/return 50/30 °C: CGB-75 from 19,6 to 75,8 kW CGB-100 from 19,6 to 98,8 kW CGB • Tested in accordance with German and European Directives; extremely clean combustion SE-2 • High standard efficiency up to 110% (Hi) / 99% (Hs) for the best possible energy utilisation • The conditions...

 Open the catalog to page 6
Gas combi boiler-10

Standard control ON / OFF Reset button Heating water temperature selector Illuminated ring DHW temperature selector Illuminated indicator ring as status display Thermometer Pressure gauge 7 3 8 1 9 5 4 6 7 3 8 2 Heat demand: pump running, burner OFF Emissions test mode Burner ON, flame steady Flashing red 2 Standby (power supply ON, burner OFF) Constant yellow 6 Flashing green Flashing yellow 5 Explanation Constant green 4 Display Fault DHW temperature selector The setting range 1-9 corresponds to a cylinder temperature of 15 to 65 °C. Combined with a control thermostat for wall mounted gas fired...

 Open the catalog to page 10
Gas combi boiler-11

Control accessories Standard controller; part of the standard delivery of the gas fired condensing boiler BM programming module (incl. outside temperature sensor) as weather-compensated control thermostat BM programming module with wall mounting base (accessory) as remote control Two-wire eBUS cable • Time programs for DHW and central heating • LCD with background illumination • Easy plain text guide through the menus • Control by rotary selector with key function • Four function keys for frequently used functions (heating, DHW, setback, help) • Installation either inside the boiler control unit...

 Open the catalog to page 11
Gas combi boiler-12

Control accessories Cascade module KM • Extension module for control of systems with low loss header or cascade configuration • Applicable for controls of condensing gas boilers (4 appliances) • Esay configuration of the controller through selection of pre-defined system options • Suitable for regulating one mixer circuit • Programming module BM may either be plugged in or used as remote control with wall mounting base • 0-10V input for building control network systems, fault signal output 230V • eBus interface with automatic energy management • Rast-5 connection technology Radio clock (DCF 77...

 Open the catalog to page 12
Gas combi boiler-13

Balanced flue routing for wall mounted gas fired boilers up to 24 kW and gas fired condensing centres C33x B23 B33 C43x C33x IIII IIII II C53x IIII II C13x IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIII C33x III I III IIII IIIIIIIII I C53 C33x C83x C33x C43x C33x System versions C33x Vertical concentric roof outlet through a pitched or flat roof, vertical concentric balanced flue routing for installation in a duct (balanced flue) C33x Horizontal roof outlet through a pitched roof (balanced flue) except CGB-11 with DN 60/100...

 Open the catalog to page 13
Gas combi boiler-14

Balanced flue routing for wall mounted gas fired boilers from 35 kW to 50 kW IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIII IIII I C33x C33x C33x C53x IIII II B23 B33 C43x II II IIIII IIIIIII I IIIIIIII I C53 C33x C83x C43x C33x C33x C83x B33 System versions Maximum length 1) [m] CGB-35 CGB-K40-35 CGB-50 C33x Vertical concentric roof outlet through a pitched or flat roof, vertical concentric balanced flue routing for installation in a duct (balanced flue) 22 13 13 C33x Horizontal roof outlet through a pitched roof (balanced...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.