1. Catalogs
  2. WOLF
  3. Commercial / industrial boilers

Commercial / industrial boilers
1 /20Pages

Commercial / industrial boilers

Commercial / industrial boilers
1 /20Pages

Catalog excerpts

Commercial / industrial boilers-1

1 Commercial / industrial boilers up to 1017 kW Steel boilers MKS Steel boilers with burner MUS Cast iron boilers MK-1/MK-2 Cast iron boilers with burner MU-1 Gas-fired boilers NG-31E/NG-31ED The competence brand for energy saving systems

 Open the catalog to page 1
Commercial / industrial boilers-2

2 Steel boiler MKS/MUS MUS with forced draught oil burner 70-100 kW MKS without forced draught oil burner 70-550 kW . MUS with forced draught oil burner for two-stage operation, design approved in accordance with DIN EN 267 for domestic fuel oil, ex-works adjusted during operation, with special mixing device for low NOX-emissions . High normative efficiency: up to 94% . Large heat exchanger surfaces made of smooth tubing for condensationfree low-temperature operation . Stainless steel turbulators inserted into heat exchanger surfaces, low flue-gas temperatures . Fully water-jacketed combustion...

 Open the catalog to page 2
Commercial / industrial boilers-4

4 Cast-iron boiler for pressure firing in accordance with DIN 4702/EN 303 and valid EC directives, for low-temperature operation. Cast iron boiler MU-1/MK-1 MU-1 with forced draught oil burner 50-110 kW MK-1 without forced draught oil burner 50-300 kW . MU-1 with forced draught oil burner for two-stage operation, design approved in accordance with DIN EN 267 for domestic fuel oil, ex-works adjusted during operation, with special mixing device for low NOX-emissions . High normative efficiency: up to 94% . Boiler elements made of durable, corrosion-resistant cast-iron . Ideally proportioned combustion...

 Open the catalog to page 4
Commercial / industrial boilers-5

5 Technical Data TYPE MU-1/MK-1 80 110 140 180 220 260 Output range MK-1 kW 50-100 80-130 110-170 140-210 180-250 220-300 Recommended range MK-1 kW 50-80 80-110 110-140 140-180 180-220 220-260 Recommended range MU-1 kW 50-80 80-110 - - - - Adjusted output MU-1 kW 80 110 - - - - Height/height without casing A mm 1220/1148 1220/1148 1220/1148 1220/1148 1220/1148 1220/1148 Width/width without casing B mm 825/585 825/585 825/585 825/585 825/585 825/585 Length C mm 1125 1285 1445 1605 1765 1925 Total height with control system D mm 1380 1380 1380 1380 1380 1380 Depth burner hood E mm 420 420 . . ....

 Open the catalog to page 5
Commercial / industrial boilers-6

6 Cast-iron boiler for pressure firing in accordance with DIN 4702/EN 303 and valid EC directives, for low-temperature operation. Cast iron boiler MK-2 MK-2 without forced draught oil burner 320-1017 kW . Stainless steel turbulators integrated in flue-gas passes . High normative efficiency: up to 94% . Boiler elements made of durable, corrosion-resistant cast-iron . Ideally proportioned combustion chamber . Cast-iron boiler door opens left/right accross entire front, easy cleaning . Amply dimensioned thermal insulation . Powder-painted casing with supreme finish, easy to assemble . Pre-wired...

 Open the catalog to page 6
Commercial / industrial boilers-8

8 Gas-fired boiler in accordance with valid EC directives with intermitted ignition. Gas-fired boiler NG-31E NG-31E with atmospheric burner 40-110 kW . Gas-fired boiler in accordance with valid EC directives with intermittent ignition and atmospheric burner for natural gas E, natural gas LL and LPG propane/butane (category II2ELL3B/P) type (construction type) B11 or B11BS (with flue-gas monitoring as accessory) Capacity range 40-110 kW . Ultra-low-pollutant combustion without flame cooling . DVGW-Quality label . High normative efficiency: up to 95% . Pre-wired control system, plug-in system for...

 Open the catalog to page 8
Commercial / industrial boilers-9

9 Technical Data TYPE NG-31E 70 90 110 Output 1st burner stage 1) kW 40,2 50,5 59,9 Charge 1st burner stage 1) kW 42,5 53,5 63,3 Output 1st + 2nd burner stage 1) kW 70,0 90,0 110,0 Charge 1st + 2nd burner stage1) kW 75,6 97,0 117,9 Height/height without casing A mm 970/650 970/650 970/650 Width/width without casing B mm 1025/880 1195/1050 1365/1220 Depth/depth without casing C mm 750/740 750/740 750/740 Total height with control system B mm 1120 1120 1120 Depth with draught security device E mm 1030 1030 1030 Boiler return F mm 220 220 220 Gas connection G mm 550 550 550 Boiler flow H mm 605...

 Open the catalog to page 9
Commercial / industrial boilers-10

10 . Gas-fired boiler in accordance with valid EC directives with intermittent ignition and atmospheric burner for natural gas E, natural gas LL und LPG propane/butane (category II2ELL3B/P) type (construction type) B11 or B11BS (with flue-gas monitoring as accessory) Capacity range 40-220 kW . Ultra-low-pollutant combustion without flame cooling . DVGW-Quality label . High normative efficiency: up to 95% . Pre-wired control system, plug-in system for easy installation . Nubbed cast-iron block to maximize the heat exchanger surface area . Snug-fitted thermal insulation, amply dimensioned . Combustion...

 Open the catalog to page 10
Commercial / industrial boilers-11

11 Technical Data TYPE NG-31ED 140 180 220 Output 1st boiler + 1st burner stage 1) kW 40,2 50,5 59,9 Charge 1st boiler + 1st burner stage 1) kW 42,5 53,5 63,3 Output 1st + 2nd boiler and 1st + 2nd burner stage 1) kW 140,0 180,0 220,0 Charge 1st +2nd boiler and 1st + 2nd burner stage 1) kW 151,2 194,0 235,8 Height/height without casing A mm 970/650 970/650 970/650 Width/width without casing B mm 1025/880 1195/1050 1365/1220 Depth/depth without casing C mm 750/740 750/740 750/740 Height with control system B mm 1120 1120 1120 Depth with draught security device E mm 1030 1030 1030 Boiler return...

 Open the catalog to page 11
Commercial / industrial boilers-12

12 Control systems for boilers and boilers with vertical hot water storages (HWS) Control system R31-STAV Control system R32 DigiCompact Boiler temperature manually adjustable; second burner stage cut-in is load-dependent. Equipment: Operating switch, burner fault indicator, boiler thermometer, boiler temperature controller adjustable from 38-78/90°C, overheat safety cutout convertible for 120/110/100°C, 2 operating-hours counters, overheat safety cutout test button, summer/winter switch. Connection of HWS: HWS-control with hot water priority, connection for HWS-thermostat (SP1). Control system...

 Open the catalog to page 12
Commercial / industrial boilers-13

13 Control systems for boilers and boilers with vertical hot water storages (HWS) Control System R33/4 DigiComfort Installation example: Control system R33 DigiComfort with one mixing valve circuit and return temperature boost. same as R33 DigiComfort, with additional control for 4 mixing valve circuits, wiring board (H/W/D 600/380/210 mm), with operating switch for OFF, Auto and emergency mode (instead of manual/ automatic switch), 2 control modules, connections for 5 heating circuit pumps. Installation example: Control system R33/4 DigiComfort with 3 mixing valve circuits and return temperature...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.