GGG388LXS
2Pages

{{requestButtons}}

Catalog excerpts

GGG388LXS - 1

® 30" (76.2 cm) Freestanding Gas Range PRODUCT MODEL NUMBERS GGG388LX PRODUCT DIMENSIONS GGG390LX B* GAS SUPPLY REQUIREMENTS Gas supply line: Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. Flexible metal appliance connector: q q If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line. A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator. q Do not kink or damage the flexible metal tubing when moving the range. q Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range. C** A D q B F A. 35³⁄₄" ± ¹⁄₈" (90.8 ± 0.3 cm) cooktop height (minimum) with leveling legs screwed all the way in B. Model/serial/rating plates (located behind the control panel)* A C A. Gas supply line B. Shutoff valve “open” position C. To range Type of Gas E*** C. 47¹⁄₈" ± ¹⁄₈" (119.7 ± 0.3 cm) overall height (minimum) with leveling legs screwed all the way in** D. 28¹⁄₂" ± ¹⁄₄" (72.4 ± 0.6 cm) depth with handle E. 26¹⁄₈" to 27¼" ± ¹⁄₈" (66.4 ± 0.3 cm)*** F. 29¹⁵⁄₁₆" ± ¹⁄₁₆" (76.0 ± 0.2 cm) width *Model/serial/rating plates may be rotated up from behind the control panel for viewing from the front of the range. **Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs. ***Excludes handle. Dimension given is from wall to front of oven door and will vary based on electrical outlet receptacle installation. Natural gas: This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. q This range is factory set for use with Natural gas. See “Gas Conversions” section. The model/serial rating plate located behind the control panel has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. LP gas conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section. ELECTRICAL REQUIREMENTS IMPORTANT: The range must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate. q A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A timedelay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided. q Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded. †® TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. Page 1 of 2 Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10345639B 12/21/10

Open the catalog to page 1
GGG388LXS - 2

CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop. D B C A E A. 18" (45.7 cm) upper cabinet to countertop B. 13" (33.0 cm) upper cabinet depth...

Open the catalog to page 2

All Whirlpool catalogs and technical brochures

  1. WGTLV27H

    1 Pages

  2. WFW560CH

    1 Pages

  3. WRF560SMH

    1 Pages

  4. WOS72EC0H

    1 Pages

  5. WGD8620H

    1 Pages

  6. WUW35X24D

    1 Pages

  7. WRF954CIH

    1 Pages

  8. WGTLV27H

    1 Pages

  9. WFW6620H

    1 Pages

  10. WFW560CH

    1 Pages

  11. WTW4950H

    1 Pages

  12. WMH32519H

    1 Pages

  13. WCG55US6H

    1 Pages

  14. WOC75EC7H

    1 Pages

  15. WEE750H0H

    1 Pages

  16. WUW55X24HS

    1 Pages

  17. WUB50X24H

    1 Pages

  18. WRB322DMHV

    1 Pages

  19. WRS588FIH

    1 Pages

  20. WRF535SMH

    1 Pages

  21. WFC8090GX

    1 Pages

  22. WET4024H

    1 Pages

  23. WED4985E

    1 Pages

  24. WTW4955H

    1 Pages

  25. WRS586FIE

    1 Pages

  26. WRS588FIH

    1 Pages

  27. WTW4950HW

    1 Pages

  28. WRS325SDHZ

    1 Pages

  29. WRT311FZDZ

    1 Pages

  30. WRS571CIHZ

    1 Pages

Archived catalogs

  1. WDT710PAYW

    2 Pages

  2. GLS3064RS

    1 Pages

  3. WOS51EC0AT

    2 Pages

  4. RBD245PRT

    1 Pages

  5. GY399LXUS

    2 Pages

  6. WDE150LVB

    1 Pages

  7. WDE150LVQ

    1 Pages

  8. GB9FHDXWB

    1 Pages

  9. GB2FHDXWS

    1 Pages

  10. WRF560SFYW

    1 Pages

  11. GX2FHDXVQ

    1 Pages

  12. GX2FHDXVB

    1 Pages

  13. WRF560SMYW

    1 Pages

  14. WED9151YW

    2 Pages

  15. WFW9151YW

    2 Pages

  16. WTW5600XW

    2 Pages

  17. WTW5500XW

    2 Pages

  18. WFC7500VW

    1 Pages