Catalog excerpts
Model WVU-72 (equipment sold separately) Cooking Appliances - Only electrically heated appliances are acceptable for installation. Cooking equipment is optional from Wells or other manufacturers. Appliances must be installed as per manufacturers instructions and controlled by the hood equipment interface contactor through a customer supplied contactor which will disable cooking equipment in the event of fire or hood malfunction. Shunt trips are not allowed. For size, temperature and KW limits see back page or manual. Exhaust and Air Flow - Exhaust air may be angled (front) or vertical (top). Hoods are shipped for vertical (top) discharge as standard. Angled front discharge is a field convertible option (kit available). Typical airflow through the hood is 1500 CFM. A minimum of 1200 cubic feet of fresh air per minute (200 cubic feet per linear foot of hood) is required into the area to comply with the Universal mechanical code and for the dilution of cooking aromas. □ Stainless Steel Rear panels DESCRIPTION Wells Universal hoods are Certified Type-1 compliant, ANSI UL710B approved recirculation hood systems and feature completely self-contained 4 stage air filtration and fire suppression systems. They do not require venting outside making it possible to cook in non-traditional locations or when traditional Type-1 hoods and duct-work are impractical, restricted or too expensive. Operators can mix and match various electric cooking equipment under the hood such as fryers, ovens, griddles, steamers and more - providing greater flexibility and production. Fire Protection - Completely self contained ANSUL® R-102 system includes ANSUL® tank, nitrogen cartridge, ANSUL® sopanifier, piping, heat sensors, ANSUL® drops, nozzles, and movable manual pull station. Manual pull can be relocated to the egress position or an additional station can be added by an authorized ANSUL® representative. Front access for easy fire system maintenance. Fire protection system meets NFPA 96 Chapter 13 and UL300. Fire protection system must be charged and certified by ANSUL® Authorized distributor after installation and before first use (operator’s responsibility). Filtration - Completely self-contained 4-Stage filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method and includes stainless steel grease baffle filter with grease cup, fiberglass pre-filters, High efficiency filter/ carbon-charcoal filter pack. All filters are easily removable without tools. Air flow sensors continually monitor air flow optimizing performance and grease removal while an interlock system will not allow cooking appliances to function if filters are missing, clogged or in the event of a fire. □ Completely self-contained, 4-stage air filtration system reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method. Maximum grease emissions are less than .0029 LB/HR/ FT (pounds per hour per foot) □ Completely self-contained fire protection system □ Very quiet with only 68 dBA average □ Interlock system will disable cooking appliances if filters are missing, clogged or in the event of a fire □ Airflow sensors continually monitor airflow for optimizing performance and grease removal □ Illuminated early-warning system to monitor filter replacement □ Four LED lights producing 500 lumens each for improved visibility - light color temperature (cool white) 6000K □ Stainless steel construction for strength, durability and ease of cleaning □ Fits through a 36” wide door opening □ 6” to 8” adjustable legs (adjustable by 2” for leveling) □ Universal systems are movable making them ideal for leased properties □ Available in 208/240V, 10 □ Limited two-year parts and one year labor warranty □ Pre-filters □ 10” to 12” adjustable legs (adjustable by 2” for leveling) □ High-Efficiency / carbon-charcoal filter packs □ Angled (front) discharge kit □ Vent Collar (for direct venting of heat out of the space) Wells ■ 10 Sunnen Dr. St. Louis, MO 63143 U.S.A. Phone : (314) 678-6314 ■ Fax (314) 781-3636 www.wellsbloomfield.com ■ Printed in the U.S.A. NOTE: SPECiFiCATiONS ARE SUBJECT TO CHANGE WiTHOUT NOTICE AND ARE NOT iNTENDED FOR iNSTALLATiON PURPOSES. SEE installatio
Open the catalog to page 1Over 90 Years Of Quality Foodservice Products And Service Universal Ventless Hood MODEL □ WVU-72 GENERAL LAYOUT DATA SANITATION MODEL WVU-72 UNIVERSAL VENTLESS HOOD SYSTEM VOLTAGE AC 60 HZ UL CAT. YZCT RECIRCULATING SYSTEM FILE NO. MH48408 SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AIR EXCHANGE AT THE INSTALLATION SITE MUST COMPLY WITH REQUIREMENTS OF THE LOCAL JURISDICTIONAL AUTHORITY. A MINIMUM OF 200 CUBIC FEET OF FRESH AIR PER MINUTE PER UNEAR FOOT OF HOOD IS REQUIRED INTO THE AREA TO COMPLY WITH THE...
Open the catalog to page 2All Wells Bloomfields catalogs and technical brochures
-
Cook & Hold Warmers
2 Pages
-
VCS 2000
2 Pages
-
WVOG136
2 Pages
-
WVO2HFG - WVO2HSG
2 Pages
-
WVU-48
2 Pages
-
WVU-26
2 Pages
-
TEA-DISPENSERS
2 Pages
-
THERMAL SERVERS
2 Pages
-
COUNTERTOP GAS GRIDDLES
28 Pages
-
HEAVY DUTY GAS GRIDDLE
32 Pages
-
OWNERS MANUAL
40 Pages
-
RW SERIES DRAWER WARMERS
4 Pages
-
WB-1, WB-2
2 Pages
-
WELLS - Ventless Hoods
7 Pages
-
WELLS - Hot/Cold
8 Pages
-
High Production Open Fryer
2 Pages
-
Oil Disposal Caddy
2 Pages
-
Soup Cookers:SC6411
2 Pages
-
Heated Dispensers:HD8799
2 Pages
-
Countertop Char Broilers:B40
2 Pages
-
Countertop Griddles:HDG2430G
2 Pages
-
Frost Tops:FT-1_FT-6
2 Pages
-
Dual Pot Fryers F676-208
2 Pages
-
Built-In Griddles:JG246UL
2 Pages
-
ventless coocking systems
6 Pages
-
Ventless Fryers:WVAE30F
2 Pages
-
2012 price list
80 Pages
Archived catalogs
-
Suggested List Price 2009
80 Pages
-
Bloomfields brochure
24 Pages