WVU-26
2Pages

{{requestButtons}}

Catalog excerpts

WVU-26 - 1

Job Over 90 Years Of Quality Foodservice Products And Service Universal Ventless Hood MODEL o WVU-26 Cooking Appliances – Only electrically heated appliances are acceptable for installation. Cooking equipment is optional from Wells or other manufacturers. Appliances must be installed as per manufacturers instructions and controlled thru the hood equipment shut-off interface through a customer supplied contractor which will disable cooking equipment in the event of fire or hood malfunction. For size, temperature and KW limits see back page or manual. Exhaust and Air Flow – Exhaust air is vertical discharge. Typical airflow is 800 CFM. A minimum of 400 cubic feet of fresh air per minute is recommended both in and out of the cooking area to ensure the dilution of cooking aromas. STANDARD FEATURES Model WVU-26 Fryer Sold Separately DESCRIPTION Wells Universal hoods are Certified Type-1 compliant, UL710B approved recirculation hood systems and feature completely self-contained air filtration and fire-suppression systems. They do not require venting outside making it possible to cook in non-traditional locations or when traditional Type-1 hoods and duct-work are impractical, restricted or too expensive. Operators may use electric cooking equipment under the hood, including a fryer, griddle, hot plate and more - providing greater flexibility and through- put. SPECIFICATIONS Fire Protection – Completely self contained ANSUL® R-102 system includes ANSUL® tank, nitrogen cartridge, ANSUL® sopanifier, piping, heat sensors, ANSUL® drops, nozzles, and movable manual pull station. Manual pull can be relocated to the egress position or an additional station can be added by an authorized ANSUL® representative. Fire protection system meets NFPA 96 Chapter 13. Fire protection system must be charged and certified by ANSUL® Authorized distributor after installation and before first use (operator’s responsibility). Filtration – Completely self-contained filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method and includes stainless steel grease baffle filter with grease cup, HEPA (High-Efficiency Particulate Air) filter/ carbon-charcoal filter pack. All filters are easily removable with out tools. Air flow sensors continually monitor air flow optimizing performance and grease removal while an interlock system will not allow cooking appliances to function if filters are missing, clogged or in the event of a fire. o Completely self-contained, 3-stage filtration system o Completely self-contained fire protections system – now accessible from the front o Very quiet with only 68 dBA average o Interlock system will disable cooking appliances if filters are missing, clogged or in the event of a fire o Airflow sensors continually monitor airflow for optimizing performance and grease removal o Illuminated early-warning system to monitor filter replacement o Completely self-contained filtration process reduces emissions below that allowed in NFPA 96 and ANSI UL710B using the EPA 202 test method o Two LED lights producing 990 lumens for improved visibilitylight color temperature (cool white) o Stainless steel construction for strength, durability and ease of cleaning o Fits through a 36” wide door opening o 6” to 8” adjustable legs (adjustable by 2” for leveling) o Universal systems are movable making them ideal for leased properties o Available in 208/240V, 1Ø o Limited two-year parts and one year labor warranty OPTIONS & ACCESSORIES o HEPA / carbon-charcoal filter pack: # WL0107 Sheet No. WELLS-WVU-26-12/14 Wells Bloomfield · 10 Sunnen Dr. St. Louis, MO 63143 U.S.A. Phone : (314) 678-6314 · Fax (314) 781-5445 www.wellsbloomfield.com · Printed in the U.S.A. NOTE: Specifications are subject to change without notice and are not intended for installation purposes. See installation instructions pr

Open the catalog to page 1
WVU-26 - 2

Over 90 Years Of Quality Foodservice Products And Service SPECIAL ENVIRONMENTAL NOTICE: THE HOOD SYSTEM IS DESIGNED TO REDUCE EMISSIONS BUT WILL NOT COMPLETELY ELIMINATE COOKING AROMAS. AIR EXCHANGE AT THE INSTALLATION SITE MUST COMPLY WITH REQUIREMENTS OF THE LOCAL JURISDICTIONAL AUTHORITY. A MINIMUM OF 400 CUBIC FEET OF FRESH AIR PER MINUTE IN AND OUT OF THE AREA IS RECOMMENDED TO ENSURE ADEQUATE DILUTION. 32.4 (823) ANSUL PULL STATION- 29.44 (748) UNDER-HOOD APPLIANCE LIMITS: 1) ELECTRICAL APPLIANCES ONLY WITH A MAXIMUM OF 22KW OUTPUT PER 24” (610MM) WIDE HOOD SECTION. 2) THE TOP OF THE...

Open the catalog to page 2

All Wells Bloomfields catalogs and technical brochures

  1. VCS 2000

    2 Pages

  2. WVOG136

    2 Pages

  3. WVU-72

    2 Pages

  4. WVU-48

    2 Pages

  5. OWNERS MANUAL

    40 Pages

  6. WB-1, WB-2

    2 Pages

Archived catalogs