Catalog excerpts
s p l a s h p r o o f ! The Specifiers and Contractors Essential Guide to Ventilation Equipment Suitable to Comply with the IEE Wiring Regulations Amendment No 3 to BS 7671:1992 (AMD 10983) Section 601 Locations Containing a Bath or Shower UNITED KINGDOM Vortice Limited Beeches House, Eastern Avenue Burton upon Trent DE13 0BB Tel: (+44)(0)1283 492949 Fax: (+44)(0)1283 544121 Email: getit@vortice.ltd.uk Web site: www.vortice.ltd.uk ITALY Vortice Elettrosociali S.p.A Strada Cerca, 2 Frazione di Zoate 20067 Tribiano (Milano) Tel: (+39) 02 906991 Fax: (+39) 02 9064625 Web Site: www.vortice.com FRANCE 72 Rue Baratte - Cholet 94106 Saint Maur CEDEX Tel: (+33) 1 55 12 5000 Fax: (+33) 1 55 12 5001 IPX4
Open the catalog to page 1The Amendment is based on the application of a zonal concept similar to that used for swimming pools, and sets requirements for safety, depending on the perceived degree of risk in each of four defined zones, and beyond. Many companies infer that 12v fans are necessary to meet this regulation. This is not the case - nowhere in this regulation or the previous version does it say that you must use expensive and unnecessary 12v fans. The new PUNTO range, in particular, has been developed specifically to meet the requirements of Amendment No 3, with the following key factors in mind: • Full...
Open the catalog to page 2601-01 Scope The particular requirements of this section apply to locations containing baths, showers and cabinets containing a shower and/or bath, and the surrounding zones. They do not apply to emergency facilities in industrial areas and laboratories. For locations containing baths or showers for medical treatment, or for disabled persons, special requirements may be necessary. 601-02 Classification of Zones 601-02-01 These requirements are based on the dimensions of four zones: zone 0, zone 1, zone 2 and zone 3. The zones are determined taking account of walls, doors, fixed partitions,...
Open the catalog to page 3Vort Press and Ariett range of centrifugal, IPX4 splashproof, recessed and surface mounted fans all with long life motors and a choice of timer or microprocessor humidity control. Recessed Fans Basic T MHC Vort Press 110i 11995 11996 Ariett i 12012 12013 12014 Bath/WC/shower • • • Vort Press 140i 11971 11972 Utility room • • Vort Press 240i 11973 11974 Kitchen • • Surface Mounted Fans Basic T MHC Vort Press 110 11967 11968 Ariett 11965 11966 11962 Ariett (Not long life) 11961 11976 Bath/WC/shower • • • Vort Press 220 11977 11978 Utility room or kitchen • • Ariett Habitat 15/30 12000 Ariett...
Open the catalog to page 4All Vortice catalogs and technical brochures
-
VORTPHON 1200
2 Pages
-
VORTPHON 2000 P
2 Pages
-
S&G DISPENSER
2 Pages
-
VORTDRY
2 Pages
-
ECODRY EC
2 Pages
-
ECODRY
2 Pages
-
VORT HRW 20 MONO RANGE
16 Pages
-
RESIDENTIAL VENTILATION
116 Pages
-
VORT QUADRO EVO RANGE
20 Pages
-
NORDIK AIR DESIGN
28 Pages
-
ELECTRIC HEATING
4 Pages
-
HYGIENE
44 Pages
-
RESIDENTIAL VENTILATION
2 Pages
-
VORT NRG RANGE
52 Pages
-
VORT QBK RANGE
60 Pages
-
Vortice Vario Range
16 Pages
Archived catalogs
-
VORTICE® LINEO
10 Pages
-
VORT QUADRO RANGE
2 Pages
-
VORTICEL E RANGE
4 Pages
-
NORDIK® INTERNATIONAL PLUS
1 Pages
-
MICRORAPID SERIES V0
1 Pages
-
VORTICE® PUNTO RANGE
8 Pages
-
VORTICE® EXTRACT UNIT RANGE
2 Pages
-
Punto Filo
8 Pages
-
Domestic Centrifugal Brochure
32 Pages
-
In Line Brochure
16 Pages
-
Prometeo HR400 Brochure
2 Pages
-
Quadro brochure
12 Pages
-
Quadro Recessed Kit Leaflet
2 Pages
-
EcoGreen Hygiene Brochure
16 Pages
-
Filo Brochure
8 Pages