VARIO-NORM
4Pages

{{requestButtons}}

Catalog excerpts

VARIO-NORM - 1

VELUXCommercial The top-selling continuous rooflight system for new buildings - European technical approved (ETA) DIBt Europaische Technische Zulassung fur „Lichtband JET-VARIO-NORM“ VARIO-NORM Threefold benefit: • light: room illumination with daylight • air: ventilation and exhaust, fresh air in the workplace • natural smoke exhaust: fire prevention With optional accessories for "fall-through protection": • e.g. LB-DSL: permanent and collective "fall-through protection" acc. to GS-BAU-18, up to 6.2 m continuous rooflight order width In many glazing variants: • tension-free placement of the glazing Simple and fast assembling: • due to a high industrial prefabrication level Circumferential on the head piece welded eave profile: • reliable drainage • very good appearance European Technical Assessment (ETA) • system tested and approved by all European building authorities • legally secure proof of placing on the market throughout Europe • 1.20 up to 11.34 m continuous rooflight order width and a 1/6 rise of the continuous rooflight width, precision finished, continuous rooflight length as desired • general type certification Nr. Z-10.19-739 VARIO-NORM continuous rooflight with smoke exhaust flap system VARIO-FIREJET® 130 J SHEV and ventilation system: • optimal SHEV and/or ventilation flap system for every continuous rooflight order width • melting out and therefore permitted as heat exhaust surface according to DIN 18230 VARIO-THERM VARIO-PROTECT Continuous rooflight fall-through protection GRILLODUR®- type LB-DSL and LB-SR vaulted continuous r

Open the catalog to page 1
VARIO-NORM - 2

Technical data Dimensions Customised daylight through the roof level for example: VARIO-NORM continuous rooflights Customised daylight through the roof level: • better room illumination than through side windows • precise dimensioning possible Rules of thumb for dimensioning: • continuous rooflight width < half of the height of the hall • distance between the continuous rooflights from each other: at least twice of the continuous rooflight width • 1/6 of the floor area as light area in the roof can be taken into account for rough planning Note: Upon request we will perform a standardized...

Open the catalog to page 2
VARIO-NORM - 3

Secure connection technology with the kerb systems 1) or customer solutions In case of continuous rooflight kerbs please provide the clear dimensions. In case of kerbs provided by the customer resp. upturns please inform us about clear opening and outer dimensions and dimension “x” (bearing width)! Please request special detailed drawings of aluminium profile constructions, bearings and glazing alternatives. Continuous rooflight kerbs 1) Rooflight kerbs provided by customer*) minimum bearing width 65 mm up to type 400 80 mm for type 500 outer dimension = order dimension clear dimension...

Open the catalog to page 3
VARIO-NORM - 4

Valid from date of publication until new edition. Version: November 2020. May contain printing errors, mistakes and technical alterations. VELUX®Commercial www.veluxcommercial.uk

Open the catalog to page 4

All VITRAL catalogs and technical brochures

  1. VARIO-THERM