Product catalog summary
Materials Needed:
  • Included: Measuring Tape, Level
  • Not Included: Cinema Round Premium x8, VicFix Base, VicFix J Profile 80mm | 3.14", Glue

The VicFix J Profile fixation system can be used with VicFix Base, which is sold separately.

Installation Procedure:
  1. Examine wall and ceiling surfaces to ensure they are clean, smooth, and dry.
  2. If surfaces are unpainted gypsum board, prime them with a drywall primer to equalize absorption, then apply paint and allow it to dry as per the manufacturer's instructions.
  3. Apply glue to the back of each acoustic panel near the edges and attach it to the wall within 10 minutes of applying the glue.
  4. Press the panel firmly against the wall for 15 seconds to ensure it stays fixed.
  5. Do not adjust the panel after bonding to maximize glue strength.
Additional Notes:
  • This method is applicable to both wall and ceiling installations.
  • Ensure the room conditions are suitable for receiving acoustic panels.
Contact Information:

Main Office, R&D & Logistics: Avenida do Pólo 3, Nº 159, Carvalhosa, 4590-137 Paços de Ferreira, Portugal

Office: Rua Quinta do Bom Retiro Nº 16, Armazém 9, 2820-690 Charneca da Caparica, Portugal

Phone: (+351) 212 964 100

Email: [email protected]

Website: www.vicoustic.com

© Vicoustic, 2021 | V2. No parts of this document may be copied or published without written consent from Vicoustic.

See more

Catalog excerpts

Cinema Round _manual_2021_V2-1

Installation Manual Cinema Round Premium

 Open the catalog to page 1
Cinema Round _manual_2021_V2-2

MATERIAL NEEDED Included Cinema Round Premium x8 Measuring Tape You may also install this product with the new VicFix J Profile fixation system using VicFix Base, sold separately. VicFix Base

 Open the catalog to page 2
Cinema Round _manual_2021_V2-3

Cut the tip of the glue nozzle according to the diagram. Apply the glue on the back of the acoustic panel, near the edges. Do not wait longer than 10 minutes after applying the glue to attach the panel to the wall. Place the panel on the suitably chose position on the wall. Once in the desired place, press firmly against the wall for 15 seconds. To ensure that you maximise the strength of the glue, don’t make any adjustments to the panel after bonding Wall and ceilling surfaces should be examined prior to installation, ensuring they are clean, smooth, and dry. If you have unpainted gypsum board...

 Open the catalog to page 3
Cinema Round _manual_2021_V2-4

Main Office, R&D & Logistics Avenida do Pólo 3, Nº 159, Carvalhosa 4590-137 Paços de Ferreira, Portugal Office Rua Quinta do Bom Retiro Nº 16, Armazém 9 2820-690 Charneca da Caparica, Portugal T  (+351) 212 964 100 Info and Sales E  [email protected] www.vicoustic.com © Vicoustic, 2021 | V2 No parts of this document might be copied and/or published without written consent of Vic

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.