Catalog excerpts

elastatec 1400-1

MULTI-PURPOSE UV-RESISTANT, HIGHLY FLEXIBLE SURFACE DRESSING

 Open the catalog to page 1
elastatec 1400-2

BAND-AID FOR BUILDINGS External | Internal 10 - 150 mm ( 3/8” - 6” ) Expansion Gaps Elastatec 1400 : A07-A09 Expansion Joint Selection Criteria Elastatec 1400 : A07 Load Rating Eurocode Rating Product Details Product Dimensions Height H2 (mm) Wall - Wall Ceiling - Ceiling Roof - Roof Product Sightline 0-10 Corner Wall Wall - Ceiling Roof - Wall General Areas of Application Specific Areas of Application Sealing of external and internal non-trafficable joints in walls, ceilings and roofs Repair of joints where sealants have failed or are no longer functional Sealing of expansion joints where anticipated...

 Open the catalog to page 2
elastatec 1400-3

External | Internal 10 - 150 mm ( 3/8” - 6” ) Expansion Gaps Features Material Highly resilient elastomeric joint tape Excellent resistance to notching and wear Durability Oil, Chemical and UV resistant Weathering and ageing resistant Industry Standards ASTM C290 ‘Standard Specification for Elastomeric Joint Seals’ compliant DIN 18540 ‘Sealing of exterior wall joints in building using joint sealants and seal tapes’ compliant External and Internal Locations External & Internal Wall to Wall Corner Wall Wall to Ceiling Ceiling to Ceiling Roof to Roof (not trafficable) Roof to Wall Parapet Walls...

 Open the catalog to page 3
elastatec 1400-4

BAND-AID FOR BUILDINGS External | Internal 10 - 150 mm ( 3/8” - 6” ) Expansion Gaps Technical Specification Product Description Elastatec Properties Elastatec 1400 is a highly resilient Polysulphide tape designed to be used to span expansion and control gaps in the external façade, roofs and interior walls and ceilings of buildings Elastatec Polysulphide tape has excellent resistance to fuels, ozone, salt water, and sunlight. Material Properties The Properties of Polysulphide Polysulphide based materials are known for their excellent resistance to solvents and lubricants as well as offering excellent...

 Open the catalog to page 4
elastatec 1400-5

External | Internal 10 - 150 mm ( 3/8” - 6” ) Expansion Gaps General Information Product Applications Elastatec 1400 is suitable for a wide range of non-trafficable applications across virtually all joint types and meets the most stringent demands of joints with expansion and compression factors up to +/-50% of expansion gap width. In the shear plane Elastatec 1400 will accommodate in excess of 25% of gap width. Elastatec tape is supplied in the following roll lengths and with the minimum order quantities: Areas of Application Designed for sealing expansion joints, control joints, isolation joints...

 Open the catalog to page 5
elastatec 1400-6

method statement application Measure Measure required distance based on the width of Elastatec tape shown in the table below. Product Tape Width Adhesive Width (each side)mm Plumb line Create plumb line based on the required measurment.

 Open the catalog to page 6
elastatec 1400-7

method statement application Prepare Surface To obtain the best sealing results, correct joint tape sizing and pre-treatment of the bonding surfaces is required. Friable concrete substrates must be prepared by grinding, sandblasting or wire brushing. Spalling, rust and all coatings on metal must be removed by sandblasting or grinding. At the time of gluing, the bonding surfaces must be clean, free of oil and grease, dry and free of substances that could prevent adhesion. Mask Edges Mask the outer edges of the bonding surface.

 Open the catalog to page 7
elastatec 1400-8

method statement application Apply Primer Apply Elastatec Primer. Elastatec B1 Primer is designed for porous surfaces. Elastatec S2 Primer is used for non-porous substrates Apply Adhesive For gaps up to 100mm wide apply a seam of Elastatec TK 51 adhesive to the primed surfaces either side of the gap. For gaps >100mm wide apply a seam of Elastatec TC 30S adhesive to the primed surfaces either side of the gap.

 Open the catalog to page 8
elastatec 1400-9

method statement application Apply Elastatec Tape Carefully apply Elastatec tape ensuring that it is affixed centrally between the taped surfaces. Remove Protective Backing Peel back and remove the white protective backing.

 Open the catalog to page 9
elastatec 1400-10

method statement application Roll Sides Using a small roller carefully roll the ribbed sides of the Elastatec tape to ensure embedment in the adhesive. Apply the roller in an outward direction towards the edges of the tape to achieve a smooth consistent finish and to prevent any excess adhesive entering the underlying gap. Remove Excess Adhesive Using a scraper remove any excess adhesive.

 Open the catalog to page 10
elastatec 1400-11

method statement application Remove Masking Tape Smooth Bond Seam Smooth the visible bond seam further by hand or with a soft brush and neutral soap solution Application Complete

 Open the catalog to page 11
elastatec 1400-13

method statement Measure Measure required distance based on the width of Elastatec tape shown in the table below. Product Tape Width Adhesive Width (each side)mm

 Open the catalog to page 13
elastatec 1400-14

method statement intersections Prepare Surface Friable concrete substrates must be prepared by grinding, sandblasting or wire brushing. Spalling, rust and all coatings on metal must be removed by sandblasting or grinding. At the time of gluing, the bonding surfaces must be clean, free of oil and grease, dry and free of substances that could prevent adhesion. Mask Edges Mask the outer edges of the bonding surface then apply Elastatec primer. Elastatec B1 Primer is designed for porous surfaces. Elastatec S2 Primer is used for non-porous substrates.

 Open the catalog to page 14
elastatec 1400-15

method statement intersections Apply Tape Apply a patch of builders tape across the junction as shown. This will prevent adhesive entering the gap. Apply Adhesive For gaps up to 100mm wide apply a seam of Elastatec TK 51 adhesive to the primed surfaces either side of the gap. For gaps >100mm wide apply a seam of Elastatec TC 30S adhesive to the primed surfaces either side of the gap.

 Open the catalog to page 15
elastatec 1400-16

method statement intersections Apply Elastatec Tape Carefully apply Elastatec tape ensuring that it is affixed centrally between the taped surfaces Apply Adhesive For gaps up to 100mm wide apply a seam of Elastatec TK 51 adhesive to the primed surfaces either side of the gap. For gaps >100mm wide apply a seam of Elastatec TC 30S adhesive to the primed surfaces either side of the gap.

 Open the catalog to page 16