Introduction
The Vestas De-Icing System (VDS) is designed to enhance wind turbine performance in cold climates by preventing ice build-up on blades, which can negatively impact the power curve. The system offers full control and transparency through a tailored de-icing strategy.
System Specifications
VDS is an active de-icing solution that integrates an ice detection system with a hot air flow unit within the blades. It is fully integrated with SCADA systems, allowing for automatic or manual activation based on a specific algorithm that detects power curve degradation.
Operational Features
The system automatically triggers de-icing only when there is an expected net power production gain, optimizing energy efficiency. It de-ices the full rotor simultaneously by heating the blades internally with hot air, targeting the outer 1/3 of the blade full chord and the outer 2/3 of the leading edge towards the tip end.
Benefits
  • Maximizes power curve recovery with targeted de-icing.
  • Low risk of lightning damage due to no electrical components in the blade's leading edge.
  • Serviceable from the hub and blade root end, ensuring safety and ease of maintenance.
  • No impact on blade profile, noise, or overall turbine performance.
  • Full SCADA integration for seamless operation.
Product Availability
VDS is available for the V112-3.3 MW™ turbine variant. Availability may vary by location, and users should consult their local Vestas contact for more information.
Design and Maintenance
The system is designed for the turbine's lifetime with no compromise on performance. Its modular design allows for simple maintenance, which can be bundled with annual service, keeping the outside of the blades maintenance-free.
Conclusion
The Vestas De-Icing System provides an efficient solution for maintaining wind turbine performance in icy conditions, ensuring business case certainty through targeted de-icing and minimal maintenance requirements.
See more

Catalog excerpts

De-icing System-1

Vestas De-Icing System Your benefits at a glance: · Targeted de-icing to maximize power curve recovery · Low risk of lightning damage · Serviceable from the hub and blade root end · Automatic setting triggers only when there is an expected net power production gain after de-icing · Full SCADA integration · No impact on blade profile, noise, or overall turbine performance · Simultaneous de-icing of full rotor set Product Availability: VDS is available for the V112-3.3 MW™ turbine variant. Check with your local Vestas contact for more information. How do you boost your business case in cold climate? Cold climates can often mean icy conditions. Ice build-up on your blades can have a negative impact on your power curve whether you de-ice or not. The Vestas De-icing System (VDS) offers full control and transparency, through a tailored de-icing strategy. VDS is an active de-icing solution consisting of an ice detection system based on your power curve and a hot air flow unit within the blades. The Vestas De-Icing System is fully SCADA integrated. Based on your tailored de-icing strategy, the system can be triggered automatically or manually. Automatic control protects your investment by using a specific algorithm to detect power curve degradation, optimizing the trigger point when the de-icing system is activated. This trigger point is the energy break-even point, where the production loss after de-icing can be regained within a few hours. Under automatic control, the turbine will stop to de-ice only when there is an expected net power production gain after de-icing. Triggering when it matters. Vestas Wind Systems A/S Hedager 44 . 8200 Aarhus N . Denmark Tel.: +45 9730 0000 . Fax: +45 9730 0001 [email protected] . vestas.com

 Open the catalog to page 1
De-icing System-2

A targeted flow of hot air heats up the outer 1/3 of the blade full chord and outer 2/3 of the leading edge to tip end. 1/3 full chord The Vestas De-Icing System de-ices the full rotor simultaneously, by heating up the blades internally with an efficient flow of hot air. Each blade contains its own de-icing system that work simultaneously to capture, heat and propel air through a specially designed outlet within the blade. Making air work for you. Can you de-ice without compromise? The Vestas De-Icing System is designed for turbine life time, with no impact to overall turbine performance. Due...

 Open the catalog to page 2

All Vestas catalogs and technical brochures

  1. Vestas 4

    4  Pages

  2. Vestas 3

    7  Pages

  3. Vestas 2

    13  Pages

  4. Vestas 1

    9  Pages

Archived catalogs

  1. Vestas_HWO

    2  Pages

  2. PowerPlus®

    12  Pages

  3. 2 MW

    16  Pages

  4. Blade Services

    12  Pages

  5. SiteHunt®

    8  Pages

  6. 4W PLATFORM

    20  Pages

  7. V90-3.0 MW®

    12  Pages

  8. 2 MW Platform

    12  Pages

  9. 3 MW PLATFORM

    16  Pages

  10. SiteDesign®

    8  Pages

  11. SiteHunt

    8  Pages

  12. MW PLATFORM

    16  Pages

  13. This is for you

    74  Pages

  14. AOM 5000

    8  Pages

  15. AOM 4000

    8  Pages

  16. AOM 1000-3000

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.