1. Catalogs
  2. Vertebra
  3. Vert LAB INTEGRATED

Vert LAB INTEGRATED
1 /24Pages

Vert LAB INTEGRATED

Vert LAB INTEGRATED
1 /24Pages

Catalog excerpts

Vert LAB INTEGRATED-1

AIRTIGHT INTEGRATED METAL CEILING SYSTEM AIRTIGHT CERTIFICATED

 Open the catalog to page 1
Vert LAB INTEGRATED-3

GUERRASIO A philosophy summarised in the company vision: technology & ideas for architecture. With three production sites, strategically located in northern, central and southern Italy, the production includes, starting from sheet metal coils, the cold working of the sheet by master carpenters, with the support of systems and numerical control machines for bending, pressing, laser cutting and powder coating. Through constant research and development, Guerrasio produces metal profiles and systems for the sector of technical interior finishes, metal ceiling systems integrated in panels, slats or...

 Open the catalog to page 3
Vert LAB INTEGRATED-4

1975 Production of aluminum doors and windows 1989 Production of gypsum board profiles

 Open the catalog to page 4
Vert LAB INTEGRATED-5

2000 Production of custom designed ceilings and claddings 2007 VERTLAB patent for a single airtight false ceiling for sterile rooms VERTLAB AIRTIGHT INTEGRATED CEILING SYSTEM cor--cocncDv— ojc'O'Kj-Lncor-'-cocDCDr— ojao'^Lncor'-.cocncD-r— ojco'cj-CDCDCDCDCDCDCDCDCDCDCDCDCDCD-c— t— v— t— t— r— v— t— v— C^JCnJCnJOJCnJ

 Open the catalog to page 5
Vert LAB INTEGRATED-6

The continuous search for quality, respect for the environment, customer and staff satisfaction, are witnessed by the certifications obtained, both for products and services and for production processes. QUALITY MANAGEMENT | ENVIRONMENTAL SYSTEM MANAGEMENT | HEALTH AND SAFETY MANAGEMENT FOR EMPLOYEES | ' System and fulfills requirements of:

 Open the catalog to page 6
Vert LAB INTEGRATED-7

THE AIRTIGHT INTEGRATED METAL CEILING SYSTEM Integrated airtight metal false ceiling (airTight patent) inspectable, composed of metal panels mounted on a hidden supporting structure made up of “inverted T” profiles. The load-bearing structure is made up of an orthogonal mesh made of galvanized steel profiles suspended from the ceiling at a distance of 120 cm by means of hanging with a 4 mm diameter galvanized steel rod, with SMART INSTALLATION AIRTIGHT CERTIFICATED AIRTIGHT PATENTED double spring for micrometric adjustment of the perfect flatness of the false ceiling. 1200 mm and 600 mm intermediate...

 Open the catalog to page 7
Vert LAB INTEGRATED-8

MAIN CHARACHTERISTICS After the installation of reverse "T" structure, the joint "Jocker" must be inserted on each intersection from above and the centring accessory from below (see fig.1). If fibres or gypsum panels of preexisting false ceilings have to be restored, the four corners must be cut in advance, in order to replace them in their former position. Finally install the new air and dust tight panel, by inserting the springs of the corners in the slots of the Joker joint (see fig. 2) and push the panel upwards. For disassembly use a suction cup for plates or panels litfing. Centring accessory...

 Open the catalog to page 8
Vert LAB INTEGRATED-9

Supporting structure Air and dust tight panel Upon request it is possible to produce further sizes with multiple module of 300 mm. Being constrained by the modularity of the T-structure, for any furhter size we suggest you to contact our Technical Department. VertLAB is a metal false ceiling especially suitable and recommended for places where air and dust tightness is required. This kind of service is required especially when it is necessary to realize: operating suites, cleanrooms or sterile rooms, chemical-biological analysis laboratories or rooms where food, cosmetic, pharmaceutical, electronic...

 Open the catalog to page 9
Vert LAB INTEGRATED-10

Direct RECESSED LED LIGHT airTight integrated suitable for installation on VertLAB false ceiling with high IP 66 protection. LIGHT Light led technology AirTight system integrated Seal and flush guaranteed with ceiling Body built totally in light aluminum alloy Minimum height (55 mm) High IP 66 protection certificated Colour rendering index Ra >90 Plexiglass led high transmittance Body: Aluminium sheet, thickness 8/10 post-painted. The apparatus is equipped with fixing accessories. Weight 4 Kg. Optical group: Colour rendering index Ra>90 Plexiglass LED high light transmittance. AIRTIGHT CERTIFICATED...

 Open the catalog to page 10
Vert LAB INTEGRATED-11

Recycling and Raee management Installation from below Special waste Suitable for installation in isolated false ceilings Protection degree RGB Emergency 3h LED modules not replaceable by the end user CONNECTING SOCKET T STRUCTURE LATERAL VIEW AIRTIGHT INTEGRATED CEILING SYSTEM

 Open the catalog to page 11
Vert LAB INTEGRATED-12

(A) Equipment option of self-test microprocessor module with: Function test, Duration test, Routine test, Occupancy sensor, DALI 2 system supported (B) Night Light Supported (day/night), RGB - DMX / DALI supported with localized touch screen (144-132 RGBW and 265-132 W-RGB) (C) Dual Power supported

 Open the catalog to page 12
Vert LAB INTEGRATED-13

INTERNAL TESTING LABORATORY HIGH QUALITY LED PANELS AIRTIGHT INTEGRATED CEILING SYSTEM

 Open the catalog to page 13
Vert LAB INTEGRATED-14

PLENUM FOR VENTILATION AND AIR CONDITIONING As far as ventilation and air-conditioning systems are concerned, our system is equipped with plenum, diffusers and extract slots, made of panels with the same aesthetic and performance characteristics of the panels. DESCRIPTION Made of sturdy 8/10 steel sheet, it guarantees the perfect airtightness for its complete integrability into the Eco-Lab false ceiling. It can be made of painted steel or stainless steel with side or top connection. • High finish and perfect tight construction; • Clinched circular connection with suitable high temperature resistant...

 Open the catalog to page 14
Vert LAB INTEGRATED-15

Technical data * DESCRIPTION The filter is made by estruded anodized aluminium frame with depth of 69 mm, equipped with micro-expanded aluminium protection with white epoxy varnish. The filter septum is made of glass microfibres, water- repellent and fireproof; the small folds have continuous thermoplastic spacers while the sealer is made of polyurethane elastomer. The tightness of the filter to the plenum can be: • Mechanical with bi-components gasket properly pressed to the plenum (1). • Liquid gasket (gel) inserted in a specific cavity obtained in the frame in which a blade with rounded profile...

 Open the catalog to page 15
Vert LAB INTEGRATED-16

SWIRL EFFECT DIFFUSER Air diffuser with or without adjustable slots (supply and extract), daisy positioned, particularly suitable for helical flows. It is used both for cooling and for heating with installation on ceilings of middle-lowheight (2.7-3.5m). Unidirectional flow diffusers upon request. -Suitable for systems with variable flow with fields between 100% and 40%. -Suitable for installations on low and middle height spaces. -Thermoplastic fins, black colour. Airflow based on the configuration of the deflectors Swirl airflow Vertical airflow Input modes based on deflector configuration