VKN
48Pages

{{requestButtons}}

Catalog excerpts

VKN - 1

Fan assisted trench heaters 2017_09 1

Open the catalog to page 1
VKN - 4

FORCED CONVECTION Heater frame Finishing layer Floor mat Cement (screed) Floor insulation layer Floor structural layer Floor styrofoam, e.g. EPS70 Levelling and fastening anchor Lattice Heater tray Return to C.H. installation C.H. installation connector Heater power and control cables OPERATING PRINCIPLE OF FORCED CONVECTION TRENCH HEATERS Convection heating systems utilize the phenomenon of heat absorption by air particles flowing through heat exchanger. The difference in densities of cold and heated air causes a delicate draft that initiates the airflow in the exchanger. Use of fan allows...

Open the catalog to page 4
VKN - 5

HIGHLY EFFICIENT HEAT EXCHANGER Research and development works allowed us to optimise sizes for heat exchangers. As the result of that we have increased the product heating output by 10 to 20%, depending of the unit length and height. DEDICATED CONTROL SYSTEM Modern room controllers allow for full control of heater operations. MODERN EC FANS Using 24V DC fan motors will provide much quicker and quiet air distribution, yet the entire product is safe and hassle free for install and maintenance. WIRELESS CONTROL Now it is a child’s play to precisely control the heaters with use of your mobile...

Open the catalog to page 5
VKN - 6

CONFIRMED QUALITY Years of thorough research, analyses and measurements, including those in the Warsaw, Cracow and Lublin Universities of Technology, Polish Academy of Sciences and own research we developed high class heating and heating-cooling devices. They increase the energy efficiency of hot / cold air supply and significantly increase the efficiency of low-temperature systems that they work with. The perfect technical parameters of Verano products were also confirmed in the tests conducted in the HEATEST s.r.o. notified body and the Heizung – Lüftung – Klimatechnik Stuttgart at the...

Open the catalog to page 6
VKN - 7

EQUIPMENT STANDARD EQUIPMENT: • tray (cover) made of hot-dip zinc-magnesium coated steel, RAL 9005 black powder coated, • highly efficient heating part - copper-aluminium heat exchanger, Black powder coat with bleeding valve, • modern fan with silent and efficient 24V DC motor • cover for connector chamber, • fan cover, so called grille, with airstream nozzles, • threaded half-union connectors • assembly struts, • fastening anchors, • tray position adjustment system. ADDITIONAL EQUIPMENT: • tray (cover) powder coated in any of the RAL palette colours, • Type L or F natural or anodized...

Open the catalog to page 7
VKN - 8

Trench length Normative heating power output [W] compliant to EN-16430 for room temperature of 0 = 20°C. Control voltages for the respective modes of operation: Min - 2 V, Med - 4 V, Max - 6 V, Boost - 10 V. Min, Med, Max fan speeds are for continuous operations, the Boost mode for fast additional heating of rooms. Sound power level according to ISO-3745 standard, sound pressure level for a distance of 2m in a room of a total volume of 100 m3 and reverb time of 0.5 s assuming room dampening of 8 dB(A).

Open the catalog to page 8
VKN - 9

Trench length Normative heating power output [W] compliant to EN-16430 for room temperature of 0 = 20°C. Control voltages for the respective modes of operation: Min - 2 V, Med - 4 V Max - 6 V, Boost - 10 V. Min, Med, Max fan speeds are for continuous operations, the Boost mode for fast additional heating of rooms. Sound power level according to ISO-3745 standard, sound pressure level for a distance of 2m in a room of a total volume of 100 m3 and reverb time of 0.5 s assuming room dampening of 8 dB(A).

Open the catalog to page 9
VKN - 10

Corrective coefficients for selection of heating power of 65mm high Verano type VKN1 heaters, for parameters different than 75/65/20°C. Heating fluid temperature [°C] Room temperature 6, [°C]

Open the catalog to page 10
VKN - 11

HEATING POWER AND ACOUSTIC PRESSURE OF VKN1-6,5/14/Lk The graphs present how heating power Φ [W] depends on the respective average temperature differences ΔT [K], for control voltages U [V]. The graphs also present the acoustic pressure levels for the respective heater operating conditions. NOTE! An example readout of control voltages and acoustic pressure for different values of heating power is included in page no. 40. VKN1-6,5/14/Lk Average temperature difference ΔT [K] Average temperature difference ΔT [K] Average temperature difference ΔT [K] Average temperature difference ΔT [K]...

Open the catalog to page 11
VKN - 12

HEATING POWER AND ACOUSTIC PRESSURE OF VKN1-6,5/17/Lk The graphs present how heating power Φ [W] depends on the respective average temperature differences ΔT [K], for control voltages U [V]. The graphs also present the acoustic pressure levels for the respective heater operating conditions. NOTE! An example readout of control voltages and acoustic pressure for different values of heating power is included in page no. 40. VKN1-6,5/17/Lk Average temperature difference ΔT [K] Average temperature difference ΔT [K] Average temperature difference ΔT [K] Average temperature difference ΔT [K]...

Open the catalog to page 12
VKN - 15

EQUIPMENT STANDARD EQUIPMENT: • tray (cover) made of hot-dip zinc-magnesium coated steel, RAL 9005 black powder coated, • highly efficient heating part - copper-aluminium heat exchanger, Black powder coat with bleeding valve, • modern fan with silent and efficient 24V DC motor • cover for connector chamber, • fan cover, so called grille, with airstream nozzles, • threaded half-union connectors • assembly struts, • fastening anchors, • tray position adjustment system. ADDITIONAL EQUIPMENT: • tray (cover) powder coated in any of the RAL palette colours, • Type L or F natural or anodized...

Open the catalog to page 15
VKN - 16

Trench length Normative heating power output [W] compliant to EN-16430 for room temperature of 0 = 20°C. Control voltages for the respective modes of operation: Min - 2 V, Med - 4 V, Max - 6 V, Boost - 10 V. Min, Med, Max fan speeds are for continuous operations, the Boost mode for fast additional heating of rooms. Sound power level according to ISO-3745 standard, sound pressure level for a distance of 2m in a room of a total volume of 100 m3 and reverb time of 0.5 s assuming room dampening of 8 dB(A).

Open the catalog to page 16

All Verano Konwektor catalogs and technical brochures

  1. CVK

    72 Pages

  2. VER-24

    1 Pages

  3. VKN SILENT

    12 Pages